In reservoirs used for geologic CO2 sequestration, brine films remaining on mineral surfaces can influence flow, diffusion, and reactions. We have investigated how the capillary (disjoining) potential influences the thickness of a KCsI2 brine film on both smooth and rough SiO2 surfaces [root mean square roughness (Rrms), 1.6 and 330 nm, respectively], under confinement with supercritical (sc) CO2. The thicknesses of brine films coating interior surfaces of SiO2windows in a high‐pressure cell were determined through synchrotron X‐ray fluorescence of two tracer ions (I− and Cs+) at 7.8 MPa and 40°C (representative of conditions at about 0.78 km below the land surface), with scCO2as the immiscible confining fluid. The measured area‐averaged film thicknesses on the 330 nm Rrms silica surface ranged from 265 to 249 nm for capillary potentials measured within a narrow range from 0.18 to 3.7 kPa. Over this same range of potentials, film thicknesses measured on the smooth (1.6 nm Rrms) silica surface were about 2 nm, although equilibrium does not appear to have been achieved. The measured average brine film thicknesses were strongly controlled by surface roughness, with very weak variation in response to the fairly narrow range of tested capillary potentials.
Brine films remaining on mineral surfaces in deep reservoirs during CO2 sequestration are expected to influence multiphase flow, diffusion, and reactions, but little is known about their behavior. Using synchrotron X‐ray fluorescence (XRF), we measured thicknesses of KCsI2 brine films on two difference roughness mica surfaces under conditions representative of geological CO2 sequestration (7.8 MPa and 40°C) to understand the influences of mineral surface roughness and capillary potential. Brine thicknesses measured on the Mica 1 (smooth) and Mica 2 (rough) mica surfaces ranged from 23 to 8 nm and 491 to 412 nm, respectively, over the small range of tested capillary potentials (0.18–3.7 kPa). Within these potentials, brine film thicknesses on mica were governed by surface roughness and only weakly influenced by capillary potentials. In comparing drainage and rewetting isotherms, some film thickness hysteresis was observed, possibly indicative of changes in mica wettability.
California’s Central Valley offers vast opportunities for CO2 storage in deep saline aquifers. We conducted an induced seismicity hazard assessment for a potential injection site in the southern San Joaquin Basin for 18 years of injection at 0.68 MtCO2/yr and 100 years of monitoring. We mapped stress, faults, and seismicity in a 30 km radius around the site to build a geomechanical model and resolve the stresses on major faults. From a 3D hydromechanical simulation of the CO2 plume, we calculated the change in pressure over time on these faults and determined the conditions for safe injection. Lacking any subsurface imaging, we also conducted a probabilistic fault slip analysis using numerous random distributions of faults and a range of geomechanical parameters. Our results show that the change in probability of fault slip can be minimized by controlling the size, migration, and magnitude of the pressure plume. We also constructed a seismic catalog for the last 20 years around the site and characterized the natural patterns of seismicity. We use these results to establish criteria for evaluating potential-induced events during the storage period and to develop a traffic light response system. This study represents a first-order procedure to evaluate the seismic hazards presented by CO2 storage and incorporate uncertainties in hydrological and geomechanical parameters.
1 April 2019 in Journal of Petroleum Science and Engineering