Background: Hypertrophic CardioMyopathy (HCM) is the most prevalent inherited cardiac disorder, where accurate assessment of Left Ventricular (LV) function and Mitral Regurgitation (MR) is crucial. Cardiac Magnetic Resonance (CMR) imaging is considered the gold standard for evaluating these parameters. Recently, Deep Learning (DL) algorithms have emerged to automate cardiac quantification, but their performance in complex pathologies such as HCM still requires validation.Purpose: To compare the performance of a fully automated deep learning-based cardiac segmentation software (SW 2) (SuiteHEART) with conventional manual segmentation (SW 1) (syngo.Via) for quantifying crucial cardiac parameters in patients with HCM.Materials and Methods: In this prospective study, 25 consecutive adult patients (mean age 49±12 years) with HCM referred for CMR at our institute were included. CMR examinations were performed by using a 3.0 Tesla scanner (Siemens Vida). The key parameters assessed included Left Ventricular Ejection Fraction (LVEF), End-Diastolic Volume (LVEDV), Stroke Volume (LVSV), Aortic Forward Flow (AoF), Mitral Regurgitation (MR), and Pressure Gradient (PG) across the LVOT. Manual and automated segmentations were performed by using syngo.Via (SW 1) and SuiteHEART software (SW 2), respectively. Statistical analysis included paired t-tests, linear regression, and Bland–Altman analysis.Results: There was a strong correlation between DL-based and manual measurements for LVEF (r=0.91), LVEDV (r=0.89), LVSV (r=0.87), AoF (r=0.86), MR (r=0.84), and PG (r=0.81) (all p<0.001). Bland–Altman analysis demonstrated acceptable limits of agreement, with no significant bias. Automated segmentation significantly reduced post-processing time compared to manual methods (p<0.001).Conclusion: Fully automated DL-based cardiac quantification provides accurate and reproducible assessment of the LV function, MR, and flow parameters in HCM patients, closely matching manual segmentation results. Incorporation of DL algorithms can substantially streamline the clinical workflow, although careful validation remains necessary in structurally complex cases such as HCM.
13 September 2024 in Indian Journal of Rheumatology
Aim: To evaluate the effectiveness of diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) mapping in diagnosing active sacroiliitis in patients with axial seronegative spondyloarthropathy (SpA). Material and Methods: This prospective study comprised 26 patients with MR imaging detected active sacroiliitis categorised as a case group, and compared them with healthy controls. ADC value measurements were obtained from the sacral and iliac sides of the bilateral S.I. joints in each case and control group. Independent samples t-test, Chi-square test, and ROC curve analysis were used. Result: Twenty-six patients had active sacroiliitis in 45 S.I. joints, unilateral active sacroiliitis was observed in seven patients (26.9%), bilateral symmetrical in three patients (11.5%) and bilateral asymmetrical in 16 patients (61.5%). The mean ADC value was 1.447 ± 0.528 [SD] × 10–3 mm 2 /s in the right S.I. joint and 1.630 ± 0.441 [SD] × 10–3 mm 2 /s in the left S.I. joint in active sacroiliitis (case group). The mean ADC value of the right S.I. joint was 0.965 ± 0.123 [SD] × 10–3 mm 2 /s and the left S.I. joint was 0.967 ± 0.96 [SD] × 10–3 mm 2 /s in inactive sacroiliitis (control group). A significant difference was observed statistically between the active sacroiliitis and the inactive sacroiliitis with a P < .0005. A cut-off mean ADC value of 1.034 ×10–3 mm 2 /s was obtained for differentiating active sacroiliitis from inactive sacroiliitis with a sensitivity of 84.6% and specificity of 84.6% from the ROC curve analysis. Conclusion: Diffusion-weighted MRI imaging with ADC value mapping acts as a sensitive diagnostic technique in the detection of active sacroiliitis in axial seronegative spondyloarthropathies and also helps in assessing the treatment response.
11 June 2025 in Indian Journal of Radiology and Imaging
Noncompaction cardiomyopathy (NCC) is a rare congenital cardiomyopathy caused by the arrest of endomyocardial morphogenesis, leading to prominent trabeculations and deep intertrabecular recesses. Emerging evidence suggests that noncompaction may also occur secondary to other myocardial pathologies or have a genetic basis. A 59-year-old male with no coronary risk factors presented with 1-year history of chest pain, palpitations, orthopnea, and fatigue. Clinical examination revealed atrial fibrillation, normal pulmonary findings, and no peripheral edema. Echocardiography showed inferior wall hypokinesia, grade I diastolic dysfunction, with ejection fraction of 48%. Cardiac magnetic resonance imaging (MRI) confirmed excessive myocardial trabeculations with reduced biventricular function. Petersen, Stacey, and Jacquier criteria established the diagnosis of biventricular noncompaction (BVNC), a rare form of NCC. The patient was managed with standard heart failure therapy. BVNC, while rare, poses diagnostic challenges and carries significant morbidity due to heart failure and arrhythmias. This case describes the importance of MRI for accurate diagnosis and tailored management in BVNC.
23 July 2026 in Indian Journal of Radiology and Imaging
Radiation protection is at a crossroads in the era of digital imaging. Although radiographic modalities have made tremendous leaps in diagnostic sensitivity, they have, in turn, added new challenges in guaranteeing proper protection against radiation. Inconsistencies in exposure protocols, lack of health worker awareness, and differing utilization of dose optimization aids still undermine the dictums of justification and ALARA (As Low As Reasonably Achievable). This commentary calls upon the radiology and medical imaging community to embrace a concerted approach to radiation safety, based on international standards and informed by strong education, technology, and policy infrastructures. Such concerted practice has the potential to harmonize safety culture across health care systems and enable imaging professionals to reduce patient and occupational exposure without diminishing diagnostic effectiveness.