Malik S. Malik

Dr. Malik S. Malik


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2023 in Journal of Engineering
Verified
Journal Article
Open access
PDF file
MJMajid Faissal Jassim
Majid Faissal Jassim
YLYousif Jabbar Lafta
Yousif Jabbar Lafta
MMMalik S. Malik
Malik S. Malik
Carbonfiber-reinforced polymer (CFRP) composites are frequently utilized in the repair and reinforcement of reinforced concrete members because they are more corrosion-resistant, durable, and flexible than commonly used materials like steel plates. Many studies have demonstrated that the use of CFRP as an internal strengthening material has a substantial impact on the shear capacity of RC beams. This research looks into the possibility of using FRP material as an externally bonded reinforcement to increase the shear strength of RC beams. Because shear improvement and mode of failure are based on the right configuration of the CFRP sheets, the experimental work consisted of eight RC beams with various types, orientations, and configurations of CFRP sheets. All beams were examined under two-point bending. The test results show that the CFRP sheet significantly improved the beam’s shear strength and ductility and that it is advantageous to orient the FRP at 45 degrees to the beam’s longitudinal axis.

11 October 2022 in Journal of Engineering
Verified
Journal Article
Open access
PDF file
MAMazin Diwan Abdullah
Mazin Diwan Abdullah
MMMalik S. Malik
Malik S. Malik
This paper examines the effectiveness of pure torsional loads on hollow reinforced concrete high-strengthened beams. Engineers need to know how much twist a structural member generates when exposed to torsional loads to design it properly. This is done through an experimental investigation of the torsional behavior of reinforced concrete (RC) beams using twelve hollow rectangular beams with varying parameters, such as the spacing of the stirrups, the influence of the steel fiber fraction, and the main reinforcement amount. Four values of fiber volume fractions (0, 0.5, 0.75, and 1), three spacings of transverse reinforcements (60,100, and 150 mm), and various longitudinal reinforcements (8Ф12mm, 6Ф12mm, and 4Ф12mm) have been used. The tested beams had the same length (1000mm), cross-sections, concrete mixture, and quality control. In the hollow beams, the interior dimensions were 180mm180mm, while the exterior dimensions were 300mm300mm. Torsional loads were applied to all the beams using custom-built test equipment. This study highlighted that the structural characteristics of hollow RC beams could be improved by increasing the fiber volume, lowering the stirrup spacing, and increasing the longitudinal reinforcement. Torsion moments rose by 132 when the fractional volume of fiber was increased from 0 to 1, while they rose by 71.27 when the longitudinal reinforcement was increased from 4 to 8bars for beams with fractional volumes of fiber of 0.5 percent and the same transverse reinforcement ratios.

1 January 2024 in Open Engineering
Verified
Journal Article
Open access
PDF file
YLYousif Jabbar Lafta
Yousif Jabbar Lafta
MMMalik S. Malik
Malik S. Malik
MJMajid Faissal Jassim
Majid Faissal Jassim
The external composite material bonding is an effective and practical method for flexural strengthening of reinforced concrete (RC) beams, providing a large opportunity to develop high-performance and cost-effective structures. Numerous uses exist for carbon fiber-reinforced polymer (CFRP) materials as RC-member strengthening methods. However, issues with bonding and de-bonding continue to be a barrier to this technique's accomplishment. In this research, the CFRP sheets were integrated as an external strengthening material to evaluate their contribution to the flexural performance and so determine how well the CFRP sheets are being used. The experimental work includes one control beam and ten RC beams with CFRP sheets as external strengthening. All beams have the same dimensions: a length of 1.7 m and a sectional area of 20 cm × 25 cm. Experimental tests were carried out with varying CFRP types, lengths, numbers, and arrangements. Each beam’s performance was evaluated in terms of failure mode, ultimate load capacity, ultimate deflection, and a load–deflection curve. The findings demonstrate the effectiveness of CFRP strengthening by demonstrating a considerable improvement in the majority of the study variables. Furthermore, the CFRP strengthening offered an exterior crack-arresting mechanism.

1 January 2023 in Open Engineering
Verified
Journal Article
Open access
PDF file
FJFardous N. Jassim
Fardous N. Jassim
SHShaimaa H. Humood
Shaimaa H. Humood
MMMalik S. Malik
Malik S. Malik
TAThatalula Q. Alshareef
Thatalula Q. Alshareef
The management of groundwater recharge success and sustainability depends on many site characteristics. It is essential to integrate the maps of site’s suitability and characteristics to identify suitable areas. The purpose of this study is to use a geographic information system (GIS) to find potential places for a project using managed aquifer recharge (MAR) in the eastern Wasit province, Iraq. Data for four effective criteria, terrain slope, Soil type/texture, drainage density, and hydrogeological efficiency, were collected, and a categorization map for each GIS criterion was subsequently created. The four steps are performed to identify this site: defining the problem, screening for the suitable areas, after the suitability map, and after the screening; the suitability mapping is divided into two zones: suitable zone and unsuitable zone. The results indicate that the site suitability for conducting aquifer recharge was classified into five categories, i.e., very high, high, moderate, low, and very low potentiality. These areas cover 26.83, 34.71, 24.98, 11.56, and 1.79%, respectively. GIS is widely acknowledged as an efficient approach for choosing MAR sites. This approach gives a better reference for analyzing suitable sites and the potential implications of applying MAR in an aquifer in similar water-stressed areas.

31 October 2024 in Mathematical Modelling of Engineering Problems
Verified
Journal Article
Open access
MMMalik S. Malik
Malik S. Malik
AAAli K. Al-Asadi
Ali K. Al-Asadi
MAMazen D. Abdullah
Mazen D. Abdullah
AKAhmed Fadhil Kadhim
Ahmed Fadhil Kadhim

Verified
Journal Article
Open access
PDF file
MZMustafa Shareef Zewair
Mustafa Shareef Zewair
AHAhid Hamoodi
Ahid Hamoodi
MMMalik S. Malik
Malik S. Malik
KNKadhim Zuboon Naser
Kadhim Zuboon Naser
This study presents an experimental investigation of reinforced concrete T-beams strengthened using ultra-high-performance concrete (UHPC) with steel plates, and in some cases, UHPC with a geotextile layer. Ten reinforced concrete specimens with the same internal reinforcement but different strengthening methods were tested. These included a control specimen and nine strengthened specimens. Four of the strengthened specimens had grooves in the wooden formwork before pouring to secure the strengthening composite plates inside it, four had it directly attached to the RC beam surface, and the last had vertical lines 10 mm deep to enhance bonding. The external composite plate consisted of four types: the first type included a composite of UHPC and steel plates as strips with 220 × 150 mm at 105 mm, while the remaining types consisted of a plate along the shear zones made of UHPC with steel, geotextiles, or steel and geotextiles. This study also included increasing the number of steel plate layers and the direction of strengthening placement. The results showed that all the strengthened beams failed in flexure, unlike the control specimen, which failed in shear. The strengthening systems improved the load-bearing capacity and overall structural behavior of the tested beams. Among the investigated specimens, beam IR-2S90SS, strengthened with two layers of steel plates, showed the highest improvement, achieving a 39.2% increase in ultimate load compared to the control beam. Debonding was observed in some specimens and was identified as one of the governing failure mechanisms. Overall, the investigated strengthening techniques demonstrated their effectiveness in improving the structural performance of reinforced T-beams.