Mustafa Shareef Zewair

Dr. Mustafa Shareef Zewair


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MZMustafa Shareef Zewair
Mustafa Shareef Zewair
AHAhid Hamoodi
Ahid Hamoodi
MMMalik S. Malik
Malik S. Malik
KNKadhim Zuboon Naser
Kadhim Zuboon Naser
This study presents an experimental investigation of reinforced concrete T-beams strengthened using ultra-high-performance concrete (UHPC) with steel plates, and in some cases, UHPC with a geotextile layer. Ten reinforced concrete specimens with the same internal reinforcement but different strengthening methods were tested. These included a control specimen and nine strengthened specimens. Four of the strengthened specimens had grooves in the wooden formwork before pouring to secure the strengthening composite plates inside it, four had it directly attached to the RC beam surface, and the last had vertical lines 10 mm deep to enhance bonding. The external composite plate consisted of four types: the first type included a composite of UHPC and steel plates as strips with 220 × 150 mm at 105 mm, while the remaining types consisted of a plate along the shear zones made of UHPC with steel, geotextiles, or steel and geotextiles. This study also included increasing the number of steel plate layers and the direction of strengthening placement. The results showed that all the strengthened beams failed in flexure, unlike the control specimen, which failed in shear. The strengthening systems improved the load-bearing capacity and overall structural behavior of the tested beams. Among the investigated specimens, beam IR-2S90SS, strengthened with two layers of steel plates, showed the highest improvement, achieving a 39.2% increase in ultimate load compared to the control beam. Debonding was observed in some specimens and was identified as one of the governing failure mechanisms. Overall, the investigated strengthening techniques demonstrated their effectiveness in improving the structural performance of reinforced T-beams.

Verified
Journal Article
Open access
PDF file
AKAtared Salah Kawoosh
Atared Salah Kawoosh
AHAhid Hamoodi
Ahid Hamoodi
MZMustafa Shareef Zewair
Mustafa Shareef Zewair
KNKadhim Zuboon Naser
Kadhim Zuboon Naser
Punching shear failure in reinforced concrete RC slabs is one of the most significant and detrimental failure modes due to its sudden nature and its dependence on a complex interaction between concrete strength, the reinforcement, and the loading conditions. In recent years, there has been increasing interest in utilizing sustainable cementitious materials and steel fibers as a way of enhancing structural performance and improving the durability of concrete. The study aims to assess the structural behavior of RC slabs utilizing a partial cement substitution with limestone powder (LP) and granulated blast-furnace slag (GBFS), with the addition of steel fibers. Twelve RC slabs were examined under uniform concentric loading to analyze cracking behavior, load–deflection relationship, stiffness variation, and ultimate punching shear strength. The results demonstrated that using limestone powder (LP) had a significant impact on the crack distribution pattern and resulted in a slight reduction in initial stiffness, with the load-bearing capacity decreasing to approximately 55.8% of the control mixture at high replacement ratios. Due to a slower hydraulic reaction than with other mixtures, increasing additional granulated blast-furnace slag resulted in a decrease in crack resistance and relative deformation. With a load-bearing capacity of approximately 92.9% of the control mixture, a tertiary mixture of limestone powder and granulated blast-furnace slag (GBFS) demonstrated a better balance in structural behavior, leading to improved crack control while maintaining a sufficient level of load-bearing capacity. The steel fibers also significantly contributed to enhanced post-cracking behavior by decreasing crack width and improving the stress redistribution mechanism within the RC slab. This led to increased punching shear resistance and enhanced energy absorption, with the ultimate load increased to 119 kN compared to the control mixture. Overall, the findings show that combining sustainable cementitious materials with steel fibers can effectively improve punching shear performance and enhance the efficiency and durability of reinforced concrete.

20 July 2026 in Fibers
Verified
Journal Article
Open access
PDF file
AHAhid Hamoodi
Ahid Hamoodi
ZAZaid Alzaidi
Zaid Alzaidi
MZMustafa Shareef Zewair
Mustafa Shareef Zewair
MMMalik S. Malik
Malik S. Malik
An experimental study was conducted to investigate the flexural behavior of continuous beams strengthened with precast concrete plates. Ten rectangular concrete beams with a cross-section of 210 × 150 mm and a total length of 2400 mm were tested under four-point loads. One specimen, without any strengthening, acted as the control, while the remaining nine were strengthened at both the positive and negative moment zones. The variables in this study were: strengthening plate thickness, length, type of bonding (epoxy or mechanical connector), bonding method (surface bonding or 10 mm grooving), type of concrete used (UHPC, SFRC, or SIFCON), and finally, the steel fiber ratio. The failure mode, cracking modes, ultimate load, load–deflection curve, stiffness and ductility were analyzed. The results showed the effectiveness of the strengthening methods, as they improved the flexural strength of the beams by 15.7% to 53%, as well as their stiffness by 15% to 173.8%, and reduced crack propagation. Also, decreasing the thickness and length of plates reduced the flexural strength by 7.28% and 23.5%, respectively. When the bonding methods were compared, the beam with mechanical bonding showed 5.7% more flexural strength than the one using epoxy. However, it was noted that all cracks in the strengthening plates were located at the bolt positions. Additionally, the use of SIFCON plates enhanced flexural strength more than UHPC and SFRC plates. However, for the SFRC plate, increasing the steel fiber content from 1.5% to 2% improved the strength by 1.2%, but this high percentage also caused cracking in the SFRC plate due to the inhomogeneity of the concrete mixture. As for the initial stiffness, the sample in which epoxy was used showed the highest value, with an increase of 173.8%, due to the uniform bonding at the connection surface. Finally, it was observed that the reference beam had the highest ductility due to the high ultimate displacement resulting from the numerous cracks that occurred in the beam, which were reduced in the strengthened beams.