Bolun Zhang

Prof. Dr. Bolun Zhang


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
BZBolun Zhang
Bolun Zhang
Feng ZhangFeng Zhang
Feng Zhang
To satisfy the electricity demands and further improve the cooling performance of scramjets, the supercritical CO2 Brayton cycle is adopted as a promising cooling and power supplying scheme. However, with the extremely high heat flux level of MW/m2, a cooling channel featuring a rectangular cross-section with non-uniform heat flow and different positions of the heated wall relative to the direction of gravity make the flow and heat transfer characteristics of supercritical CO2 within scramjet cooling channel extremely complex. In this study, the effects of different angles of the heated wall normal direction relative to the direction of gravity (θ) on the flow and heat transfer behavior of supercritical CO2 within a scramjet cooling channel are comprehensively investigated. The results show that the spanwise heat transfer coefficient on the heated wall decreases while on the opposite wall it increases as θ increases. Moreover, the overall heat transfer performance is insensitive to variations in θ, but the heat transfer characteristics on different walls are sensitive to variations in θ. Moreover, the cases with lower θ provide better heat transfer performance for the heated wall, which is more significant for scramjet cooling due to having the highest heat load. In detail, the averaged HTC on the HW of θ = 180 deg for G = 900 kg/(m2s) is reduced by 11.79% in comparison to that of θ = 0 deg, while it is enhanced by 18.70%, 6.39% and 6.39% for the OW, LW and RW, respectively.

17 July 2026 in Aerospace
Verified
Journal Article
Open access
PDF file
BZBolun Zhang
Bolun Zhang
JXJun Xia
Jun Xia
To push the specific impulse and power output of the thrust-controlled solid rocket motor (TCSRM) even higher, the solid-propellant flame temperature is driven to 3000–3600 K. That level of thermal assault subjects the pintle to extreme heat flux and aggressive erosion, a combination that directly undercuts motor reliability. An effective cooling strategy for the pintle is therefore mandatory. Here, a film-cooling scheme is deployed for thermal protection of the pintle, and a comprehensive study on the transient aero-thermal characteristics of pintle film cooling is carried out to demonstrate how it outperforms the uncooled baseline in extending pintle survival and to reveal the effects of the blowing ratio and pintle moving speed on the performance. The results indicate that the film cooling contributes to improving the pintle cooling performance. As pintle velocity increases, the absolute velocity component of the coolant jet parallel to the mainstream velocity decreases. This causes the relative angle between the coolant jet and mainstream to increase, leading to a stronger interaction between the coolant jet and mainstream. Accordingly, except under low-blowing-ratio conditions, the time-averaged film-cooling effectiveness declines as the pintle velocity increases. Moreover, there is an optimum blowing ratio to achieve the highest time-averaged film-cooling effectiveness.

17 August 2026 in Energies
Verified
Journal Article
Open access
PDF file
BZBolun Zhang
Bolun Zhang
JXJun Xia
Jun Xia
This investigation introduces a conceptual configuration for an innovative combined cooling and power (CCP) arrangement that harnesses waste thermal energy from a supercritical carbon dioxide (sCO2) power loop through integration with a cascading transcritical CO2 cycle coupled with a lithium bromide–water vapor absorption chiller (tCO2/LiBr-H2O VAR). A systematic comparative assessment of thermodynamic behavior and exergoeconomic characteristics was executed across three configurations: the newly proposed CCP scheme, a hybrid sCO2/tCO2 power system, and a conventional standalone sCO2 engine. Parametric sensitivity analyses were conducted to evaluate how various operating parameters influence overall system effectiveness, while particle swarm optimization (PSO) was employed to determine the optimal exergetic efficiency peaks and minimum unit product costs for each architecture. Findings demonstrate that the proposed CCP topology delivers exergy efficiency enhancements of 8.46% and 1.65% relative to the standalone sCO2 configuration and the combined sCO2/tCO2 arrangement, respectively. Correspondingly, reductions in total product unit costs reach 2.80% and 0.80% for the same comparisons. These outcomes confirm that employing a cascading tCO2/LiBr-H2O VAR subsystem as the bottoming cycle represents a compelling solution for cooling and power production.

27 July 2026 in Processes
Verified
Journal Article
Open access
PDF file
JXJun Xia
Jun Xia
BZBolun Zhang
Bolun Zhang
XHXiao-Ping Hu
Xiao-Ping Hu
For unshrouded turbine blades, the high-speed tip clearance leakage flow induced by the pressure gradient on the pressure and suction surface sides significantly increases the thermal load in the turbine blade tip regions. Film cooling technology is an effective measure for reducing the external heat transfer temperature at the blade tips. Novel cooling strategies for the turbine blade tip are introduced to reduce adiabatic wall temperature. Here, the spatial distribution of film cooling effectiveness and the associated flow physics of the rib-slot and trapezoidal-slot tip configurations are investigated numerically and experimentally under transonic conditions. Film cooling effectiveness on the tip is quantified using the pressure-sensitive paint technique. Density ratios of 1.5 and 2.0 are considered, with tip clearances set at 0.7% and 1.5% of the blade height and the cascade exit Mach number set at 1.05. Both the trapezoidal-slot and rib-slot tip cooling approaches are capable of establishing complete film coverage over the tip surface. The rib-slot configuration delivers markedly higher effectiveness values over the mid-chord and trailing-edge regions relative to the trapezoidal-slot design. Conversely, the trapezoidal-slot scheme improves tip aerodynamic performance compared with the rib-slot arrangement, with the benefit being most pronounced in the larger clearance setting.