Armando Viviano Razionale

Prof. Armando Viviano Razionale

Department of Civil and Industrial Engineering, University of Pisa
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2011 in ISPRS Journal of Photogrammetry and Remote Sensing
Verified
Journal Article
Closed access
Fabio BrunoFabio Bruno
Fabio Bruno
GBGianfranco Bianco
Gianfranco Bianco
MMM. Muzzupappa
M. Muzzupappa
SBSandro Barone
Sandro Barone
Armando Viviano RazionaleArmando Viviano Razionale
Armando Viviano Razionale

10 May 2020 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Francesco TamburrinoFrancesco Tamburrino
Francesco Tamburrino
Vincenzo D'AntòVincenzo D'Antò
Vincenzo D'Antò
Rosaria BucciRosaria Bucci
Rosaria Bucci
GBGiulio Alessandri Bonetti
Giulio Alessandri Bonetti
SBSandro Barone
Sandro Barone
Armando Viviano RazionaleArmando Viviano Razionale
Armando Viviano Razionale
The use of metal-free thermoplastic materials plays a key role in the orthodontic digital workflow due to the increasing demand for clear aligner treatments. Three thermoplastic polymers commonly used to fabricate clear aligners, namely Duran®, Biolon® and Zendura®, were investigated to evaluate the effect of thermoforming (T.), storage in artificial saliva (S.A.S.) and their combination on their mechanical properties. Elastic modulus and yield stress of the specimens were characterized. Each material was characterized for each condition through tensile tests (ISO527-1). The results showed that thermoforming does not lead to a significant decrease in yield stress, except for Zendura® that showed about a 30% decrease. An increase of the elastic modulus of Duran® and Zendura®, instead, was observed after thermoforming. The same increase was noticed for the yield stress of Duran®. For S.A.S. specimens, the elastic modulus generally decreases compared to supplier condition (A.S.) and simply thermoformed material. A decrease of yield stress, instead, is significant for Zendura®. The results demonstrated that the impact of the operating conditions on the mechanical properties can vary according to the specific polymer. To design reliable and effective orthodontic treatments, the materials should be selected after their mechanical properties are characterized in the simulated intraoral environment.

9 September 2019 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
Rosaria BucciRosaria Bucci
Rosaria Bucci
Roberto RongoRoberto Rongo
Roberto Rongo
CLCarmine Levatè
Carmine Levatè
AMAmbra Michelotti
Ambra Michelotti
SBSandro Barone
Sandro Barone
Vincenzo D'AntòVincenzo D'Antò
Vincenzo D'Antò
Background: Clear aligners (CA) are among the most chosen orthodontic therapies for patients who require an invisible treatment. Previous studies showed that the thermoforming process and the complexity of the intraoral environment might alter the properties of these devices. The aim of the current prospective clinical study was to assess the thickness changes of the CA after 10 days of intraoral use. The secondary aim was to assess the reproducibility of the thermoforming process, in terms of aligner thickness. Materials and methods: CA from 18 consecutive patients (13 women, 5 men, mean age 28.8 ± 9.6 years) were investigated. Before intraoral exposure (T0), the thickness of the unused CA was measured at different occlusal points on a 3D model with a dedicated software (Geomagic Qualify 2013; 3D Systems, Rock Hill, SC, USA). Two CA configurations were studied: passive maxillary aligner (P—no tooth movement; no shape for attachments) and active maxillary aligner (A—tooth movement; shape for attachments and divot). The used aligners were returned after 10 days (T1) and the thickness measurements were repeated. A Student’s t test for paired data (T1 vs. T0) was applied to compare the thicknesses of used and unused devices (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014). Furthermore, to study the reproducibility of the thermoforming process, P and A aligners were thermoformed twice, and the thicknesses of the two unused thermoformed devices were compared by means of Student’s t test for paired data (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014) and Dahlberg’s error. Results: The thermoforming process showed good reproducibility for both aligner configurations, with a maximum Dahlberg’s error of 0.13 mm. After intraoral use, the thickness of P showed some statistically significant, but not clinically relevant, thickness changes as compared to the unused aligners, while A did not show any significant changes. Conclusion: Considering the thickness changes, the thermoforming process is reliable both with active and passive aligner configurations. Also, the CA examined show good thickness stability after physiological intraoral ageing in a population of healthy adults.

1 November 2019 in The Angle Orthodontist
Verified
Journal Article
Closed access
SMStefano Martina
Stefano Martina
RRRoberto Rongo
Roberto Rongo
Rosaria BucciRosaria Bucci
Rosaria Bucci
Armando Viviano RazionaleArmando Viviano Razionale
Armando Viviano Razionale
Rosa VallettaRosa Valletta
Rosa Valletta
Vincenzo D'AntòVincenzo D'Antò
Vincenzo D'Antò
Objectives: To investigate the in vitro cytotoxicity of different thermoplastic materials for clear aligners on human primary gingival fibroblasts (HGFs). Materials and Methods: Four materials for clear aligners were considered in this study: Duran (Scheu-Dental GmbH, Iserlohn, Germany), Biolon (Dreve Dentamid GmbH, Unna, Germany), Zendura (Bay Materials LLC, Fremont, CA, USA), and SmartTrack (Align Technology, San Jose, CA, USA). Three out of four materials (Duran, Biolon, Zendura) were assessed as thermoformed and nonthermoformed, whereas the SmartTrack was assessed only as thermoformed. The samples were placed at 37°C in airtight test tubes containing Dulbecco's Modified Eagle's Medium (DMEM; 0.1 mg/mL) for 14 days. The cell viability of HGFs cultured with this medium was assessed by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. Data were analyzed by means of one-way and two-way analysis of variance and post hoc tests (α = 0.05). Results: Each material exhibited a slight cytotoxic effect after 14 days. The highest cytotoxicity level on HGFs was achieved by Biolon (64.6% ± 3.3 of cell viability), followed by Zendura (74.4% ± 2.3 of cell viability), SmartTrack (78.8% ± 6.3 of cell viability), and finally Duran (84.6% ± 4 of cell viability), which was the least cytotoxic. In the comparison between nonthermoformed and thermoformed materials for Duran, Biolon, and Zendura, the thermoformed materials showed the highest level of cytotoxicity ( P < .001). Conclusions: Under the experimental conditions of this study, all the materials for clear aligners presented a slight cytotoxicity. Biolon was the most cytotoxic and the thermoforming process increased the cytotoxicity of the materials.

4 March 2021 in Virtual and Physical Prototyping
Verified
Journal Article
Closed access
Francesco TamburrinoFrancesco Tamburrino
Francesco Tamburrino
SBSandro Barone
Sandro Barone
Alessandro PaoliAlessandro Paoli
Alessandro Paoli
Armando Viviano RazionaleArmando Viviano Razionale
Armando Viviano Razionale
The potential of additive manufacturing to produce optimised and customized polymeric parts is often impaired by poor surface finish, low mechanical properties, and insufficient dimensional accuracy. Post-processing treatments are usually adopted to address these issues. Scientific community and industrial actors are engaged in the development and use of post-processing to enhance the performance and widen the range of application of polymeric components manufactured by additive technologies. The present work aims to provide an exhaustive classification and discussion of the post-processing treatments, as well as an extensive literature review of the approaches proposed within the scientific community. A holistic view of post-processing is provided, including a discussion of the benefits associated with each technique as well as its side effects. This work is intended to support the selection of the most appropriate post-processing by considering multiple aspects such as the material, part geometry, processing time, costs, and treatment specificity.

21 October 2016 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SBSandro Barone
Sandro Barone
Alessandro PaoliAlessandro Paoli
Alessandro Paoli
Armando Viviano RazionaleArmando Viviano Razionale
Armando Viviano Razionale
RSR. Savignano
R. Savignano
Transparent and removable aligners represent an effective solution to correct various orthodontic malocclusions through minimally invasive procedures. An aligner‐based treatment requires patients to sequentially wear dentition‐mating shells obtained by thermoforming polymeric disks on reference dental models. An aligner is shaped introducing a geometrical mismatch with respect to the actual tooth positions to induce a loading system, which moves the target teeth toward the correct positions. The common practice is based on selecting the aligner features (material, thickness, and auxiliary elements) by only considering clinician's subjective assessments.In this article, a computational design and engineering methodology has been developed to reconstruct anatomical tissues, to model parametric aligner shapes, to simulate orthodontic movements, and to enhance the aligner design. The proposed approach integrates computer‐aided technologies, from tomographic imaging to optical scanning, from parametric modeling to finite element analyses, within a 3‐dimensional digital framework.The anatomical modeling provides anatomies, including teeth (roots and crowns), jaw bones, and periodontal ligaments, which are the references for the down streaming parametric aligner shaping. The biomechanical interactions between anatomical models and aligner geometries are virtually reproduced using a finite element analysis software. The methodology allows numerical simulations of patient‐specific conditions and the comparative analyses of different aligner configurations.In this article, the digital framework has been used to study the influence of various auxiliary elements on the loading system delivered to a maxillary and a mandibular central incisor during an orthodontic tipping movement. Numerical simulations have shown a high dependency of the orthodontic tooth movement on the auxiliary element configuration, which should then be accurately selected to maximize the aligner's effectiveness.