Flora Silva

Dr. Flora Silva

Polytechnic Institute of Bragança, Bragança, Portugal
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Flora SilvaFlora Silva
Flora Silva
Ana Maria Antão-GeraldesAna Maria Antão-Geraldes
Ana Maria Antão-Geraldes
CZCarmem Zavattieri
Carmem Zavattieri
MAMaria João Almeida Pinto dos Santos Afonso
Maria João Almeida Pinto dos Santos Afonso
FFFlávio Freire
Flávio Freire
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
This study aimed to determine the water demand of a municipal swimming pool complex to propose water use efficiency measures. Concomitantly, the possibility of recycling and reusing the water from filter backwashing was evaluated. The pools consumed 25.6% of water, the filter backwashing 24.5%, and the showers 34.7%. Despite the current impossibility of reducing water consumption in pools and filter backwashing, it is feasible to promote more efficient use of water through reducing water consumption by adopting simple water-saving initiatives for showers, taps, and flushing cisterns. These were organized into three distinct scenarios: (a) flushing cistern volume adjustment and the replacement of washbasin and kitchen taps; (b) flushing cistern volume adjustment and shower replacement and (c) flushing cistern volume adjustment, shower, washbasin, and kitchen taps replacement. Under scenarios 1, 2, and 3, the water consumption reduction was 8.0, 13.2, and 20.4%, respectively. The initial investment for scenario 1 was €2290.5, €859.0 for scenario 2 and €3149.5 for scenario 3; the annual water bill reduction was €7115.4, €11,518.1, and €17,655.9, respectively. Therefore, the turnover of the investment was four (scenario 1), one (scenario 2), and three months (scenario 3). The filter washings attained the required standard for irrigation after being subjected to 15 h of sedimentation.

25 March 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Flora SilvaFlora Silva
Flora Silva
Cristina Sousa Coutinho CalheirosCristina Sousa Coutinho Calheiros
Cristina Sousa Coutinho Calheiros
GVGuilherme Valle
Guilherme Valle
PPPedro Pinto
Pedro Pinto
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
Ana Maria Antão-GeraldesAna Maria Antão-Geraldes
Ana Maria Antão-Geraldes
In the face of excessive soil sealing and the occurrence of heavy rainfall in short time periods leading to flooding, it is becoming increasingly urgent to implement public resilient stormwater drainage systems. Green roofs have several advantages at different levels, of which this paper highlights the ability to retain rainwater, to reduce problems with flooding in peaks of rainfall, and to increase in urban green infrastructure with all the benefits associated. In this sense, green roofs’ impact on the design of a public stormwater drainage system and their implications for urban stormwater management was analyzed when compared with conventional roofs. If green roofs are used on the buildings in the study urban area, which has about 2.1 ha and is located in rainfall region B of Portugal, then the weighted average runoff coefficient (Cm) for the study area is 0.59. This scenario leads to a reduction in the maximum flow rate of 15.89% compared to the use of conventional roofs, with a Cm of 0.70 for the same area. Thus, the use of green roofs instead of conventional roofs can have positive impacts on the surface runoff in urban areas and contribute to more sustainable urban drainage.

8 March 2021 in INTED Proceedings
Verified
Open access
PBPaula Maria Barros
Paula Maria Barros
Flora SilvaFlora Silva
Flora Silva
ECEliana Lessa Cordeiro
Eliana Lessa Cordeiro
INTED2021 Proceedings, with ISBN 978-84-09-27666-0 at IATED Digital Library

16 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Flora SilvaFlora Silva
Flora Silva
Cristina Sousa Coutinho CalheirosCristina Sousa Coutinho Calheiros
Cristina Sousa Coutinho Calheiros
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
JLJorge Lopes
Jorge Lopes
Ana Maria Antão-GeraldesAna Maria Antão-Geraldes
Ana Maria Antão-Geraldes
Given the high annual water consumption for non-potable uses (1112.08 m3, 65%) of an industrial building with a large roof area (4638 m2) located in the Northeast of Portugal, this study aims to evaluate the technical and financial feasibility of a rainwater harvesting system for these uses, considering the existing conventional roof (scenario 1) and adapting a green roof to the existing roof (scenario 2). This evaluation was based on the impact of the two scenarios on the building’s water savings. Under scenarios 1 and 2, the expected water savings were 64.47% and 59.43%, respectively. Therefore, the expected reduction in the annual water bill was €3867.07 + VAT (scenario 1) and €3564.63 + VAT (scenario 2). For scenario 1, considering a reservoir with 70 m3 for non-potable purposes, such as washing the building’s floor and use in industrial machines, and an initial investment of €41,109.13 + VAT, the single payback will be 11.29 years. The single payback for scenario 2 largely exceeded the lifetime of the green roof. However, as they are considered interesting solutions to reduce the negative externalities of industrial settlements, financial incentives could be proposed for the implementation of the green roof in this typology of buildings.

27 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ana Maria Antão-GeraldesAna Maria Antão-Geraldes
Ana Maria Antão-Geraldes
GOGabriel Ohara
Gabriel Ohara
MAMaria João Almeida Pinto dos Santos Afonso
Maria João Almeida Pinto dos Santos Afonso
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
Flora SilvaFlora Silva
Flora Silva
This research is focused on the water usage patterns in two student residences—one for male students (Residence I) and the other for female students (Residence II). Surveys and measurements of flushing cisterns, taps, and shower flows were conducted to understand water use behaviors. Scenario 1 proposed replacing washbasin and kitchen taps and installing flow reducers in showers, while Scenario 2 combined Scenario 1 with a rainwater harvesting system for recharging flush cisterns. Showers were found to be the most water-consuming devices, accounting for 46% and 61.41% of water consumption in Residences I and II, respectively, followed by kitchen taps (31.51% in Residence I and 11.52% in Residence II). The flushing cistern consumption was 7.02% in Residence I and 13.22% in Residence II. The implementation of Scenario 1 anticipates a 13% reduction in total water consumption in Residence I and a 10% reduction in Residence II. The reduction in hot water consumption would result in a decrease in annual electricity consumption by 27.8% and 23.06% in Residence I and II, respectively. With the implementation of Scenario 2, the total potential water savings for Residence I could increase to 19.98%, and for Residence II, it could rise to 23.17%. The proposed measures aim to enhance water sustainability in these buildings and can be replicated elsewhere.

18 March 2023 in Hydrology
Verified
Journal Article
Open access
PDF file
Ana Maria Antão-GeraldesAna Maria Antão-Geraldes
Ana Maria Antão-Geraldes
MPMatheus Pinto
Matheus Pinto
MAMaria João Almeida Pinto dos Santos Afonso
Maria João Almeida Pinto dos Santos Afonso
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
Cristina Sousa Coutinho CalheirosCristina Sousa Coutinho Calheiros
Cristina Sousa Coutinho Calheiros
Flora SilvaFlora Silva
Flora Silva
This study aimed to determine the water demand of a Municipal Market building to propose water use efficiency measures. The flushing cisterns have the highest water consumption (63.15%), followed by washbasins, restaurant and coffee shop taps, and hairdresser’s showerhead (31.64%). Therefore, the implementation of two main categories of solutions: reducing water consumption through the adoption of efficient devices and installing a rainwater harvesting system (RWHS) when drinking water quality is not required, was evaluated. These solutions were organized in four distinct scenarios: (1) Flushing cistern replacement by dual-flush ones; (2) washbasins, restaurant, coffee shop taps, and hairdresser showerhead replacement; (3) scenario 1 combined to a RWHS for recharging the replaced flushing cisterns and (4) combining scenarios 3 and 4. Under scenarios 1, 2, 3, and 4, the expected water consumption reduction was 28.36%, 17.06%, 57.36%, and 74.41%, respectively. As a result, the annual water bill reduction was €3835.81 (scenario 1), €2307.07 (scenario 2), €7757.65 (scenario 3), and €10,064.73 (scenario 4). Furthermore, to ensure the harvested rainwater attains the required standard for recharge flushing cisterns, it is advisable to dispose of the first-flush rainwater collected after a long dry period.