Maria João Almeida Pinto dos Santos Afonso

Dr. Maria João Almeida Pinto dos Santos Afonso


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Flora SilvaFlora Silva
Flora Silva
Ana Maria Antão-GeraldesAna Maria Antão-Geraldes
Ana Maria Antão-Geraldes
CZCarmem Zavattieri
Carmem Zavattieri
MAMaria João Almeida Pinto dos Santos Afonso
Maria João Almeida Pinto dos Santos Afonso
FFFlávio Freire
Flávio Freire
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
This study aimed to determine the water demand of a municipal swimming pool complex to propose water use efficiency measures. Concomitantly, the possibility of recycling and reusing the water from filter backwashing was evaluated. The pools consumed 25.6% of water, the filter backwashing 24.5%, and the showers 34.7%. Despite the current impossibility of reducing water consumption in pools and filter backwashing, it is feasible to promote more efficient use of water through reducing water consumption by adopting simple water-saving initiatives for showers, taps, and flushing cisterns. These were organized into three distinct scenarios: (a) flushing cistern volume adjustment and the replacement of washbasin and kitchen taps; (b) flushing cistern volume adjustment and shower replacement and (c) flushing cistern volume adjustment, shower, washbasin, and kitchen taps replacement. Under scenarios 1, 2, and 3, the water consumption reduction was 8.0, 13.2, and 20.4%, respectively. The initial investment for scenario 1 was €2290.5, €859.0 for scenario 2 and €3149.5 for scenario 3; the annual water bill reduction was €7115.4, €11,518.1, and €17,655.9, respectively. Therefore, the turnover of the investment was four (scenario 1), one (scenario 2), and three months (scenario 3). The filter washings attained the required standard for irrigation after being subjected to 15 h of sedimentation.

27 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ana Maria Antão-GeraldesAna Maria Antão-Geraldes
Ana Maria Antão-Geraldes
GOGabriel Ohara
Gabriel Ohara
MAMaria João Almeida Pinto dos Santos Afonso
Maria João Almeida Pinto dos Santos Afonso
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
Flora SilvaFlora Silva
Flora Silva
This research is focused on the water usage patterns in two student residences—one for male students (Residence I) and the other for female students (Residence II). Surveys and measurements of flushing cisterns, taps, and shower flows were conducted to understand water use behaviors. Scenario 1 proposed replacing washbasin and kitchen taps and installing flow reducers in showers, while Scenario 2 combined Scenario 1 with a rainwater harvesting system for recharging flush cisterns. Showers were found to be the most water-consuming devices, accounting for 46% and 61.41% of water consumption in Residences I and II, respectively, followed by kitchen taps (31.51% in Residence I and 11.52% in Residence II). The flushing cistern consumption was 7.02% in Residence I and 13.22% in Residence II. The implementation of Scenario 1 anticipates a 13% reduction in total water consumption in Residence I and a 10% reduction in Residence II. The reduction in hot water consumption would result in a decrease in annual electricity consumption by 27.8% and 23.06% in Residence I and II, respectively. With the implementation of Scenario 2, the total potential water savings for Residence I could increase to 19.98%, and for Residence II, it could rise to 23.17%. The proposed measures aim to enhance water sustainability in these buildings and can be replicated elsewhere.

1 September 2025 in Clean Technologies
Verified
Journal Article
Open access
PDF file
IAInês Santos Afonso
Inês Santos Afonso
CDCristina Duarte
Cristina Duarte
MAMaria João Almeida Pinto dos Santos Afonso
Maria João Almeida Pinto dos Santos Afonso
ARAntónio E Ribeiro
António E Ribeiro
Joana AmaralJoana Amaral
Joana Amaral
João RibeiroJoão Ribeiro
João Ribeiro
Olive mill wastewaters (OMWW) generated during olive oil extraction represent a significant environmental challenge due to their high organic matter content, acidic pH, phenolic content, and toxicity. Their composition varies widely depending on the extraction method and remains difficult to treat, particularly for small-scale producers lacking access to complex infrastructure. This study evaluates the combined effect of the extraction system (traditional vs. three-phase continuous) and filtration level (single vs. double) on the physicochemical and biological properties of OMWW. The methodologies employed included the analysis of water content, density, fatty acid composition, acidity, pH, total solids, chemical and biochemical oxygen demand, and biodegradability. The results indicate that traditional systems consistently produced OMWW with higher organic matter and phenolic loads, while filtration moderately reduced antioxidant potential and acidity, especially in traditional systems. The use of simple, low-cost filtration materials proved effective in improving effluent clarity and could serve as a practical pre-treatment option. This approach offers an accessible strategy for small producers aiming to valorise OMWW or reduce environmental impact. However, the study was conducted at the laboratory scale, and the long-term behaviour of filtered OMWW under real operating conditions remains to be evaluated.

18 March 2023 in Hydrology
Verified
Journal Article
Open access
PDF file
Ana Maria Antão-GeraldesAna Maria Antão-Geraldes
Ana Maria Antão-Geraldes
MPMatheus Pinto
Matheus Pinto
MAMaria João Almeida Pinto dos Santos Afonso
Maria João Almeida Pinto dos Santos Afonso
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
Cristina Sousa Coutinho CalheirosCristina Sousa Coutinho Calheiros
Cristina Sousa Coutinho Calheiros
Flora SilvaFlora Silva
Flora Silva
This study aimed to determine the water demand of a Municipal Market building to propose water use efficiency measures. The flushing cisterns have the highest water consumption (63.15%), followed by washbasins, restaurant and coffee shop taps, and hairdresser’s showerhead (31.64%). Therefore, the implementation of two main categories of solutions: reducing water consumption through the adoption of efficient devices and installing a rainwater harvesting system (RWHS) when drinking water quality is not required, was evaluated. These solutions were organized in four distinct scenarios: (1) Flushing cistern replacement by dual-flush ones; (2) washbasins, restaurant, coffee shop taps, and hairdresser showerhead replacement; (3) scenario 1 combined to a RWHS for recharging the replaced flushing cisterns and (4) combining scenarios 3 and 4. Under scenarios 1, 2, 3, and 4, the expected water consumption reduction was 28.36%, 17.06%, 57.36%, and 74.41%, respectively. As a result, the annual water bill reduction was €3835.81 (scenario 1), €2307.07 (scenario 2), €7757.65 (scenario 3), and €10,064.73 (scenario 4). Furthermore, to ensure the harvested rainwater attains the required standard for recharge flushing cisterns, it is advisable to dispose of the first-flush rainwater collected after a long dry period.