Changwon Wang

Prof. Changwon Wang

Soonchunhyang University

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSungHun Kim
SungHun Kim
Changwon WangChangwon Wang
Changwon Wang
Se Dong MinSe Dong Min
Se Dong Min
SLSeung-Hyun Lee
Seung-Hyun Lee
In the Korean construction industry, legal and institutional safety management improvements are continually being pursued. However, there was a 4.5% increase in the number of workers’ deaths at construction sites in 2017 compared to the previous year. Failure to wear safety helmets seems to be one of the major causes of the increase in accidents, and so it is necessary to develop technology to monitor whether or not safety helmets are being used. However, the approaches employed in existing technical studies on this issue have mainly involved the use of chinstrap sensors and have been limited to the problem of whether or not safety helmets are being worn. Meanwhile, improper wearing, such as when the chinstrap and harness fixing of the safety helmet are not properly tightened, has not been monitored. To remedy this shortcoming, a sensing safety helmet with a three-axis accelerometer sensor attached was developed in this study. Experiments were performed in which the sensing data were classified whether the safety helmet was being worn properly, not worn, or worn improperly during construction workers’ activities. The results verified that it is possible to differentiate among wearing status of the proposed safety helmet with a high accuracy of 97.0%.

12 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Changwon WangChangwon Wang
Changwon Wang
Young KimYoung Kim
Young Kim
Hangsik ShinHangsik Shin
Hangsik Shin
Se Dong MinSe Dong Min
Se Dong Min
Post-stroke gait dysfunction occurs at a very high prevalence. A practical method to quantitatively analyze the characteristics of hemiparetic gait is needed in both clinical and community settings. This study developed a 10-channeled textile capacitive pressure sensing insole (TCPSI) with a real-time monitoring system and tested its performance through hemiparetic gait pattern analysis. Thirty-five subjects (18 hemiparetic, 17 healthy) walked down a 40-m long corridor at a comfortable speed while wearing TCPSI inside the shoe. For gait analysis, the percentage of the plantar pressure difference (PPD), the step count, the stride time, the coefficient of variation, and the phase coordination index (PCI) were used. The results of the stroke patients showed a threefold higher PPD, a higher step count (41.61 ± 10.7), a longer average stride time on the affected side, a lower mean plantar pressure on the affected side, higher plantar pressure in the toe area and the lateral side of the foot, and a threefold higher PCI (hemi: 19.50 ± 13.86%, healthy: 5.62 ± 5.05%) compared to healthy subjects. This study confirmed that TCPSI is a promising tool for distinguishing hemiparetic gait patterns and thus may be used as a wearable gait function evaluation tool, the external feedback gait training device, and a simple gait pattern analyzer for both hemiparetic patients and healthy individuals.

26 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Changwon WangChangwon Wang
Changwon Wang
Young KimYoung Kim
Young Kim
DKDae Gyeom Kim
Dae Gyeom Kim
SLSeung-Hyun Lee
Seung-Hyun Lee
Se Dong MinSe Dong Min
Se Dong Min
Stair falls on construction sites are leading causes of fatal injuries, and the dangers for workers are greater because they usually carry heavy loads. Nevertheless, there are very few studies related to stair falls among construction workers. The purpose of this study was to detect near fall incidence during stair descent and analyze the changes in weight bearing and center of pressure. A total of 10 healthy males participated in this study. Three experimental conditions were set up to analyze stair falls: natural descent (E1), weighted descent (E2), and near fall-simulated descent (E3). While walking down the stairs, subjects wore a three-axis accelerometer sensor attached to a Smart Helmet and a pair of textile pressure sensors (insole) placed inside Smart Shoes. The collected data were analyzed for: (1) whole body balance, (2) plantar pressure distribution, (3) head tilt pattern, and (4) conformity between the helmet and insole sensors. The results showed that our proposed smart helmet and smart shoes have relatively good performance in terms of classifying the weight-shifting patterns in the head and the feet during stair descent. The results of this study may be helpful in detecting near falls of workers on construction sites.

30 November 2018 in Materials
Verified
Journal Article
Open access
PDF file
Changwon WangChangwon Wang
Changwon Wang
Young KimYoung Kim
Young Kim
Se Dong MinSe Dong Min
Se Dong Min
Spatiotemporal analysis of gait pattern is meaningful in diagnosing and prognosing foot and lower extremity musculoskeletal pathologies. Wearable smart sensors enable continuous real-time monitoring of gait, during daily life, without visiting clinics and the use of costly equipment. The purpose of this study was to develop a light-weight, durable, wireless, soft-material-based smart insole (SMSI) and examine its range of feasibility for real-time gait pattern analysis. A total of fifteen healthy adults (male: 10, female: 5, age 25.1 ± 2.64) were recruited for this study. Performance evaluation of the developed insole sensor was first executed by comparing the signal accuracy level between the SMSI and an F-scan. Gait data were simultaneously collected by two sensors for 3 min, on a treadmill, at a fixed speed. Each participant walked for four times, randomly, at the speed of 1.5 km/h (C1), 2.5 km/h (C2), 3.5 km/h (C3), and 4.5 km/h (C4). Step count from the two sensors resulted in 100% correlation in all four gait speed conditions (C1: 89 ± 7.4, C2: 113 ± 6.24, C3: 141 ± 9.74, and C4: 163 ± 7.38 steps). Stride-time was concurrently determined and R2 values showed a high correlation between the two sensors, in both feet (R2 ≥ 0.90, p < 0.05). Bilateral gait coordination analysis using phase coordination index (PCI) was performed to test clinical feasibility. PCI values of the SMSI resulted in 1.75 ± 0.80% (C1), 1.72 ± 0.81% (C2), 1.72 ± 0.79% (C3), and 1.73 ± 0.80% (C4), and those of the F-scan resulted in 1.66 ± 0.66%, 1.70 ± 0.66%, 1.67 ± 0.62%, and 1.70 ± 0.62%, respectively, showing the presence of a high correlation (R2 ≥ 0.94, p < 0.05). The insole developed in this study was found to have an equivalent performance to commercial sensors, and thus, can be used not only for future sensor-based monitoring device development studies but also in clinical setting for patient gait evaluations.

8 November 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
SKSungHun Kim
SungHun Kim
Changwon WangChangwon Wang
Changwon Wang
Se Dong MinSe Dong Min
Se Dong Min
SLSeung-Hyun Lee
Seung-Hyun Lee
In the Korean construction industry, legal and institutional safety management improvements are continually being pursued. However, there was a 4.5% increase in the number of workers’ deaths at construction sites in 2017 compared to the previous year. Failure to wear safety helmets seems to be one of the major causes of the increase in accidents, and so it is necessary to develop technology to monitor whether or not safety helmets are being used. However, the approaches employed in existing technical studies on this issue have mainly involved the use of chinstrap sensors and have been limited to the problem of whether or not safety helmets are being worn. Meanwhile, improper wearing, such as when the chinstrap and harness fixing of the safety helmet are not properly tightened, has not been monitored. To remedy this shortcoming, a sensing safety helmet with a three-axis accelerometer sensor attached was developed in this study. Experiments were performed in which the sensing data were classified whether the safety helmet was being worn properly, not worn, or worn improperly during construction workers’ activities. The results verified that it is possible to differentiate among wearing status of the proposed safety helmet with a high accuracy of 97.0%

23 November 2016 in Lecture Notes in Electrical Engineering
Verified
Book Chapter
Closed access
PDF file
Changwon WangChangwon Wang
Changwon Wang
SLSangjoon Lee
Sangjoon Lee
JHJonggab Ho
Jonggab Ho
YNYeji Na
Yeji Na
Se Dong MinSe Dong Min
Se Dong Min