Young Kim

Dr. Young Kim

Department of Software Convergence, Soonchunhyang University, Asan, Chungnam, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Changwon WangChangwon Wang
Changwon Wang
Young KimYoung Kim
Young Kim
Hangsik ShinHangsik Shin
Hangsik Shin
Se Dong MinSe Dong Min
Se Dong Min
Post-stroke gait dysfunction occurs at a very high prevalence. A practical method to quantitatively analyze the characteristics of hemiparetic gait is needed in both clinical and community settings. This study developed a 10-channeled textile capacitive pressure sensing insole (TCPSI) with a real-time monitoring system and tested its performance through hemiparetic gait pattern analysis. Thirty-five subjects (18 hemiparetic, 17 healthy) walked down a 40-m long corridor at a comfortable speed while wearing TCPSI inside the shoe. For gait analysis, the percentage of the plantar pressure difference (PPD), the step count, the stride time, the coefficient of variation, and the phase coordination index (PCI) were used. The results of the stroke patients showed a threefold higher PPD, a higher step count (41.61 ± 10.7), a longer average stride time on the affected side, a lower mean plantar pressure on the affected side, higher plantar pressure in the toe area and the lateral side of the foot, and a threefold higher PCI (hemi: 19.50 ± 13.86%, healthy: 5.62 ± 5.05%) compared to healthy subjects. This study confirmed that TCPSI is a promising tool for distinguishing hemiparetic gait patterns and thus may be used as a wearable gait function evaluation tool, the external feedback gait training device, and a simple gait pattern analyzer for both hemiparetic patients and healthy individuals.

26 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Changwon WangChangwon Wang
Changwon Wang
Young KimYoung Kim
Young Kim
DKDae Gyeom Kim
Dae Gyeom Kim
SLSeung-Hyun Lee
Seung-Hyun Lee
Se Dong MinSe Dong Min
Se Dong Min
Stair falls on construction sites are leading causes of fatal injuries, and the dangers for workers are greater because they usually carry heavy loads. Nevertheless, there are very few studies related to stair falls among construction workers. The purpose of this study was to detect near fall incidence during stair descent and analyze the changes in weight bearing and center of pressure. A total of 10 healthy males participated in this study. Three experimental conditions were set up to analyze stair falls: natural descent (E1), weighted descent (E2), and near fall-simulated descent (E3). While walking down the stairs, subjects wore a three-axis accelerometer sensor attached to a Smart Helmet and a pair of textile pressure sensors (insole) placed inside Smart Shoes. The collected data were analyzed for: (1) whole body balance, (2) plantar pressure distribution, (3) head tilt pattern, and (4) conformity between the helmet and insole sensors. The results showed that our proposed smart helmet and smart shoes have relatively good performance in terms of classifying the weight-shifting patterns in the head and the feet during stair descent. The results of this study may be helpful in detecting near falls of workers on construction sites.

30 November 2018 in Materials
Verified
Journal Article
Open access
PDF file
Changwon WangChangwon Wang
Changwon Wang
Young KimYoung Kim
Young Kim
Se Dong MinSe Dong Min
Se Dong Min
Spatiotemporal analysis of gait pattern is meaningful in diagnosing and prognosing foot and lower extremity musculoskeletal pathologies. Wearable smart sensors enable continuous real-time monitoring of gait, during daily life, without visiting clinics and the use of costly equipment. The purpose of this study was to develop a light-weight, durable, wireless, soft-material-based smart insole (SMSI) and examine its range of feasibility for real-time gait pattern analysis. A total of fifteen healthy adults (male: 10, female: 5, age 25.1 ± 2.64) were recruited for this study. Performance evaluation of the developed insole sensor was first executed by comparing the signal accuracy level between the SMSI and an F-scan. Gait data were simultaneously collected by two sensors for 3 min, on a treadmill, at a fixed speed. Each participant walked for four times, randomly, at the speed of 1.5 km/h (C1), 2.5 km/h (C2), 3.5 km/h (C3), and 4.5 km/h (C4). Step count from the two sensors resulted in 100% correlation in all four gait speed conditions (C1: 89 ± 7.4, C2: 113 ± 6.24, C3: 141 ± 9.74, and C4: 163 ± 7.38 steps). Stride-time was concurrently determined and R2 values showed a high correlation between the two sensors, in both feet (R2 ≥ 0.90, p < 0.05). Bilateral gait coordination analysis using phase coordination index (PCI) was performed to test clinical feasibility. PCI values of the SMSI resulted in 1.75 ± 0.80% (C1), 1.72 ± 0.81% (C2), 1.72 ± 0.79% (C3), and 1.73 ± 0.80% (C4), and those of the F-scan resulted in 1.66 ± 0.66%, 1.70 ± 0.66%, 1.67 ± 0.62%, and 1.70 ± 0.62%, respectively, showing the presence of a high correlation (R2 ≥ 0.94, p < 0.05). The insole developed in this study was found to have an equivalent performance to commercial sensors, and thus, can be used not only for future sensor-based monitoring device development studies but also in clinical setting for patient gait evaluations.

1 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JHJong Gab Ho
Jong Gab Ho
Young KimYoung Kim
Young Kim
Se Dong MinSe Dong Min
Se Dong Min
Center of pressure refers to the centroid of the ground reaction force vector detected underneath the walking foot, which is a summary measure representing body segment movements during human locomotion. In this study, we developed a cost-effective, lightweight insole-type textile capacitive sensor (I-TCPs) to analyze plantar pressure (PP) distribution and center of pressure (COP) trajectory. To test the accuracy of I-TCPs, the measured pressure data was compared with that of F-scan. The sensor performance test was divided into a static baseline test and a dynamic gait experiment, both at two different gait speeds self-selected by the subjects. Static gait results showed that I-TCPs were capable of recognizing PP segments at different gait speeds. Dynamic gait results showed an average RMSE of 1.29 ± 0.47 mm in COPx (mediolateral shift) and 12.55 ± 5.08 mm in COPy (anteroposterior shift) at a comfortable gait speed. The COP correlation between I-TCPs and F-scan was 0.54 ± 0.09 in COPx and 0.92 ± 0.04 in COPy in comfortable gait speed conditions, in which COPy values presented a stronger correlation. RMSE and correlation in fast gait speed conditions also showed similar results. The findings of this study can be the basis for future research, including rehabilitation engineering, developing ICT devices, and creating smart wearable sensors to improve quality of life for patients and healthy individuals.

14 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
VCVantha Chhoeum
Vantha Chhoeum
Young KimYoung Kim
Young Kim
Se Dong MinSe Dong Min
Se Dong Min
The lower limb joints might be affected by different shoe types and gait speeds. Monitoring joint angles might require skill and proper technique to obtain accurate data for analysis. We aimed to estimate the knee joint angle using a textile capacitive sensor and artificial neural network (ANN) implementing with three shoe types at two gait speeds. We developed a textile capacitive sensor with a simple structure design and less costly placing in insole shoes to measure the foot plantar pressure for building the deep learning models. The smartphone was used to video during walking at each condition, and Kinovea was applied to calibrate the knee joint angle. Six ANN models were created; three shoe-based ANN models, two speed-based ANN models, and one ANN model that used datasets from all experiment conditions to build a model. All ANN models at comfortable and fast gait provided a high correlation efficiency (0.75 to 0.97) with a mean relative error lower than 15% implement for three testing shoes. And compare the ANN with A convolution neural network contributes a similar result in predict the knee joint angle. A textile capacitive sensor is reliable for measuring foot plantar pressure, which could be used with the ANN algorithm to predict the knee joint angle even using high heel shoes.

7 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
XGXIN GUO
XIN GUO
Young KimYoung Kim
Young Kim
XNXueli Ning
Xueli Ning
Se Dong MinSe Dong Min
Se Dong Min
The Transformer model has received significant attention in Human Activity Recognition (HAR) due to its self-attention mechanism that captures long dependencies in time series. However, for Inertial Measurement Unit (IMU) sensor time-series signals, the Transformer model does not effectively utilize the a priori information of strong complex temporal correlations. Therefore, we proposed using multi-layer convolutional layers as a Convolutional Feature Extractor Block (CFEB). CFEB enables the Transformer model to leverage both local and global time series features for activity classification. Meanwhile, the absolute position embedding (APE) in existing Transformer models cannot accurately represent the distance relationship between individuals at different time points. To further explore positional correlations in temporal signals, this paper introduces the Vector-based Relative Position Embedding (vRPE), aiming to provide more relative temporal position information within sensor signals for the Transformer model. Combining these innovations, we conduct extensive experiments on three HAR benchmark datasets: KU-HAR, UniMiB SHAR, and USC-HAD. Experimental results demonstrate that our proposed enhancement scheme substantially elevates the performance of the Transformer model in HAR.