Takafumi Akamatsu

Dr. Takafumi Akamatsu

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2016 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
RTRuoming Tian
Ruoming Tian
CWChunlei Wan
Chunlei Wan
YWYifeng Wang
Yifeng Wang
QWQingshuo Wei
Qingshuo Wei
TITakao Ishida
Takao Ishida
KKKunihito Koumoto
Kunihito Koumoto
Solution-processed flexible TiS2/organic superlattice films may find applications in powering wearable electronics.

17 September 2013 in Sensors
Verified
Journal Article
Open access
PDF file
TATakafumi Akamatsu
Takafumi Akamatsu
TIToshio Itoh
Toshio Itoh
NINoriya Izu
Noriya Izu
Woosuck ShinWoosuck Shin
Woosuck Shin
Semiconductor-based gas sensors that use n-type WO3 or p-type Co3O4 powder were fabricated and their gas sensing properties toward NO2 or NO (0.5–5 ppm in air) were investigated at 100 °C or 200 °C. The resistance of the WO3-based sensor increased on exposure to NO2 and NO. On the other hand, the resistance of the Co3O4-based sensor varied depending on the operating temperature and the gas species. The chemical states of the surface of WO3 or those of the Co3O4 powder on exposure to 1 ppm NO2 and NO were investigated by diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy. No clear differences between the chemical states of the metal oxide surface exposed to NO2 or NO could be detected from the DRIFT spectra.

4 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
YSYuichi Sakumura
Yuichi Sakumura
YKYutaro Koyama
Yutaro Koyama
HTHiroaki Tokutake
Hiroaki Tokutake
THToyoaki Hida
Toyoaki Hida
KSKazuo Sato
Kazuo Sato
Woosuck ShinWoosuck Shin
Woosuck Shin
Monitoring exhaled breath is a very attractive, noninvasive screening technique for early diagnosis of diseases, especially lung cancer. However, the technique provides insufficient accuracy because the exhaled air has many crucial volatile organic compounds (VOCs) at very low concentrations (ppb level). We analyzed the breath exhaled by lung cancer patients and healthy subjects (controls) using gas chromatography/mass spectrometry (GC/MS), and performed a subsequent statistical analysis to diagnose lung cancer based on the combination of multiple lung cancer-related VOCs. We detected 68 VOCs as marker species using GC/MS analysis. We reduced the number of VOCs and used support vector machine (SVM) algorithm to classify the samples. We observed that a combination of five VOCs (CHN, methanol, CH3CN, isoprene, 1-propanol) is sufficient for 89.0% screening accuracy, and hence, it can be used for the design and development of a desktop GC-sensor analysis system for lung cancer.

10 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
TIToshio Itoh
Toshio Itoh
TMToshio Miwa
Toshio Miwa
ATAkihiro Tsuruta
Akihiro Tsuruta
TATakafumi Akamatsu
Takafumi Akamatsu
NINoriya Izu
Noriya Izu
YSYasuhiro Setoguchi
Yasuhiro Setoguchi
Various volatile organic compounds (VOCs) in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS) for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls), and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls). The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis.

1 October 2013 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
TIToshio Itoh
Toshio Itoh
TNTakaomi Nakashima
Takaomi Nakashima
TATakafumi Akamatsu
Takafumi Akamatsu
NINoriya Izu
Noriya Izu
Woosuck ShinWoosuck Shin
Woosuck Shin

9 May 2014 in Sensors
Verified
Journal Article
Open access
PDF file
NPNam-Hee Park
Nam-Hee Park
TATakafumi Akamatsu
Takafumi Akamatsu
TIToshio Itoh
Toshio Itoh
NINoriya Izu
Noriya Izu
Woosuck ShinWoosuck Shin
Woosuck Shin
A novel miniaturized calorimeter-type sensor device with a dual-catalyst structure was fabricated by integrating different catalysts on the hot (Pd/θ-Al2O3) and cold (Pt/α-Al2O3) ends of the device. The device comprises a calorimeter with a thermoelectric gas sensor (calorimetric-TGS), combining catalytic combustion and thermoelectric technologies. Its response for a model fuel gas of hydrogen and methane was investigated with various combustor catalyst compositions. The calorimetric-TGS devices detected H2, CH4, and a mixture of the two with concentrations ranging between 200 and 2000 ppm at temperatures of 100–400 °C, in terms of the calorie content of the gases. It was necessary to reduce the much higher response voltage of the TGS to H2 compared to CH4. We enhanced the H2 combustion on the cold side so that the temperature differences and response voltages to H2 were reduced. The device response to H2 combustion was reduced by 50% by controlling the Pt concentration in the Pt/α-Al2O3 catalyst on the cold side to 3 wt%.