Samanta Rosati

Dr. Samanta Rosati

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
SRSamanta Rosati
Samanta Rosati
GBGabriella Balestra
Gabriella Balestra
MKMarco KNAFLITZ
Marco KNAFLITZ
Human Activity Recognition (HAR) refers to an emerging area of interest for medical, military, and security applications. However, the identification of the features to be used for activity classification and recognition is still an open point. The aim of this study was to compare two different feature sets for HAR. Particularly, we compared a set including time, frequency, and time-frequency domain features widely used in literature (FeatSet_A) with a set of time-domain features derived by considering the physical meaning of the acquired signals (FeatSet_B). The comparison of the two sets were based on the performances obtained using four machine learning classifiers. Sixty-one healthy subjects were asked to perform seven different daily activities wearing a MIMU-based device. Each signal was segmented using a 5-s window and for each window, 222 and 221 variables were extracted for the FeatSet_A and FeatSet_B respectively. Each set was reduced using a Genetic Algorithm (GA) simultaneously performing feature selection and classifier optimization. Our results showed that Support Vector Machine achieved the highest performances using both sets (97.1% and 96.7% for FeatSet_A and FeatSet_B respectively). However, FeatSet_B allows to better understand alterations of the biomechanical behavior in more complex situations, such as when applied to pathological subjects.

1 January 2017 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
SRSamanta Rosati
Samanta Rosati
Valentina AgostiniValentina Agostini
Valentina Agostini
MKMarco Knaflitz
Marco Knaflitz
GBGabriella Balestra
Gabriella Balestra
Human gait is characterized by a large stride-to-stride variability of the muscle activation patterns (onset-offset timings). For this reason prolonged walking sessions lasting several minutes are analyzed. To interpret correctly the electromyographic (EMG) data collected during gait, it is important to group strides sharing similar EMG activation patterns. The aim of this work is to present and validate a method, based on hierarchical clustering, able to group strides showing homogeneous onset-offset activation intervals. Results show that the variability of the onset-offset timing is significantly reduced after clustering, for all of the five lower limb muscles considered to test this method. A by-product of the clustering procedure is the possibility to define and extract the principal activations of a muscle during gait. We define principal activations those activations that are necessary for the specific muscle contribution to the biomechanical function of walking. This concept may be useful whenever the dynamic performance of the muscle has to be compared in subsequent times, such as in patient's follow-up or when the performance of a specific subject is to be compared to that of a group of selected subjects. The contribution presented in this work could be beneficial in implementing a personalized medicine approach to rehabilitation. Clinical gait analysis, enriched by hierarchical clustering of EMG patterns as well as by the quantitative assessment of muscles principal activations, could greatly contribute to the design of therapeutic treatments tailored on the patient's needs

1 September 2020 in International Journal of Cancer
Verified
Journal Article
Closed access
PDF file
Valentina GianniniValentina Giannini
Valentina Giannini
SRSamanta Rosati
Samanta Rosati
ADArianna Defeudis
Arianna Defeudis
GBGabriella Balestra
Gabriella Balestra
LVLorenzo Vassallo
Lorenzo Vassallo
DRDaniele Regge
Daniele Regge

7 March 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
CCC. Castagneri
C. Castagneri
Valentina AgostiniValentina Agostini
Valentina Agostini
SRSamanta Rosati
Samanta Rosati
GBG. Balestra
G. Balestra
MKM. Knaflitz
M. Knaflitz
Gait asymmetry is typically evaluated using spatio-temporal or joint kinematics parameters. Only a few studies addressed the problem of defining an asymmetry index directly based on muscle activity, extracting parameters from surface electromyography (sEMG) signals. Moreover, no studies used the extraction of the muscle principal activations (activations that are necessary for accomplishing a specific motor task) as the base to construct an asymmetry index, less affected by the variability of sEMG patterns. The aim of this study is to define a robust index to quantitative assess the asymmetry of muscle activations during locomotion, based on the extraction of the principal activations. SEMG signals were analyzed combining Statistical Gait Analysis (SGA) and a clustering algorithm that allows for obtaining the muscle principal activations. We evaluated the asymmetry levels of four lower limb muscles in: (1) healthy subjects of different ages (children, adults, and elderly); (2) different populations of orthopedic patients (adults with megaprosthesis of the knee after bone tumor resection, elderly subjects after total knee arthroplasty and elderly subjects after total hip arthroplasty); and (3) neurological patients (children with hemiplegic cerebral palsy and elderly subjects affected by idiopathic Normal Pressure Hydrocephalus). The asymmetry index obtained for each pathological population was then compared to that of age-matched controls. We found asymmetry levels consistent with the expected impact of the different pathologies on muscle activation during gait. This suggests that the proposed index can be successfully used in clinics for an objective assessment of the muscle activation asymmetry during locomotion.

30 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
NGNoemi Giordano
Noemi Giordano
SRSamanta Rosati
Samanta Rosati
MKMarco KNAFLITZ
Marco KNAFLITZ
The signal quality limits the applicability of phonocardiography at the patients’ domicile. This work proposes the signal-to-noise ratio of the recorded signal as its main quality metrics. Moreover, we define the minimum acceptable values of the signal-to-noise ratio that warrantee an accuracy of the derived parameters acceptable in clinics. We considered 25 original heart sounds recordings, which we corrupted by adding noise to decrease their signal-to-noise ratio. We found that a signal-to-noise ratio equal to or higher than 14 dB warrants an uncertainty of the estimate of the valve closure latencies below 1 ms. This accuracy is higher than that required by most clinical applications. We validated the proposed method against a public database, obtaining results comparable to those obtained on our sample population. In conclusion, we defined (a) the signal-to-noise ratio of the phonocardiographic signal as the preferred metric to evaluate its quality and (b) the minimum values of the signal-to-noise ratio required to obtain an uncertainty of the latency of heart sound components compatible with clinical applications. We believe these results are crucial for the development of home monitoring systems aimed at preventing acute episodes of heart failure and that can be safely operated by naïve users.

7 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
NGNoemi Giordano
Noemi Giordano
SRSamanta Rosati
Samanta Rosati
GBGabriella Balestra
Gabriella Balestra
MKMarco KNAFLITZ
Marco KNAFLITZ
The home monitoring of patients affected by chronic heart failure (CHF) is of key importance in preventing acute episodes. Nevertheless, no wearable technological solution exists to date. A possibility could be offered by Cardiac Time Intervals extracted from simultaneous recordings of electrocardiographic (ECG) and phonocardiographic (PCG) signals. Nevertheless, the recording of a good-quality PCG signal requires accurate positioning of the stethoscope over the chest, which is unfeasible for a naïve user as the patient. In this work, we propose a solution based on multi-source PCG. We designed a flexible multi-sensor array to enable the recording of heart sounds by inexperienced users. The multi-sensor array is based on a flexible Printed Circuit Board mounting 48 microphones with a high spatial resolution, three electrodes to record an ECG and a Magneto-Inertial Measurement Unit. We validated the usability over a sample population of 42 inexperienced volunteers and found that all subjects could record signals of good to excellent quality. Moreover, we found that the multi-sensor array is suitable for use on a wide population of at-risk patients regardless of their body characteristics. Based on the promising findings of this study, we believe that the described device could enable the home monitoring of CHF patients soon.