Noemi Giordano

Dr. Noemi Giordano

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NGNoemi Giordano
Noemi Giordano
MKMarco KNAFLITZ
Marco KNAFLITZ
The auscultation of heart sounds has been for decades a fundamental diagnostic tool in clinical practice. Higher effectiveness can be achieved by recording the corresponding biomedical signal, namely the phonocardiographic signal, and processing it by means of traditional signal processing techniques. An unavoidable processing step is the heart sound segmentation, which is still a challenging task from a technical viewpoint—a limitation of state-of-the-art approaches is the unavailability of trustworthy techniques for the detection of heart sound components. The aim of this work is to design a reliable algorithm for the identification and the classification of heart sounds’ main components. The proposed methodology was tested on a sample population of 24 healthy subjects over 10-min-long simultaneous electrocardiographic and phonocardiographic recordings and it was found capable of correctly detecting and classifying an average of 99.2% of the heart sounds along with their components. Moreover, the delay of each component with respect to the corresponding R-wave peak and the delay among the components of the same heart sound were computed: the resulting experimental values are coherent with what is expected from the literature and what was obtained by other studies.

3 September 2021 in Prostate Cancer and Prostatic Diseases
Verified
Journal Article
Closed access
PDF file
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
SRSamanta Rosati
Samanta Rosati
SCSabrina De Cillis
Sabrina De Cillis
MVMarica Vagni
Marica Vagni
NGNoemi Giordano
Noemi Giordano
FPFrancesco Porpiglia
Francesco Porpiglia

30 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
NGNoemi Giordano
Noemi Giordano
SRSamanta Rosati
Samanta Rosati
MKMarco KNAFLITZ
Marco KNAFLITZ
The signal quality limits the applicability of phonocardiography at the patients’ domicile. This work proposes the signal-to-noise ratio of the recorded signal as its main quality metrics. Moreover, we define the minimum acceptable values of the signal-to-noise ratio that warrantee an accuracy of the derived parameters acceptable in clinics. We considered 25 original heart sounds recordings, which we corrupted by adding noise to decrease their signal-to-noise ratio. We found that a signal-to-noise ratio equal to or higher than 14 dB warrants an uncertainty of the estimate of the valve closure latencies below 1 ms. This accuracy is higher than that required by most clinical applications. We validated the proposed method against a public database, obtaining results comparable to those obtained on our sample population. In conclusion, we defined (a) the signal-to-noise ratio of the phonocardiographic signal as the preferred metric to evaluate its quality and (b) the minimum values of the signal-to-noise ratio required to obtain an uncertainty of the latency of heart sound components compatible with clinical applications. We believe these results are crucial for the development of home monitoring systems aimed at preventing acute episodes of heart failure and that can be safely operated by naïve users.

7 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
NGNoemi Giordano
Noemi Giordano
SRSamanta Rosati
Samanta Rosati
GBGabriella Balestra
Gabriella Balestra
MKMarco KNAFLITZ
Marco KNAFLITZ
The home monitoring of patients affected by chronic heart failure (CHF) is of key importance in preventing acute episodes. Nevertheless, no wearable technological solution exists to date. A possibility could be offered by Cardiac Time Intervals extracted from simultaneous recordings of electrocardiographic (ECG) and phonocardiographic (PCG) signals. Nevertheless, the recording of a good-quality PCG signal requires accurate positioning of the stethoscope over the chest, which is unfeasible for a naïve user as the patient. In this work, we propose a solution based on multi-source PCG. We designed a flexible multi-sensor array to enable the recording of heart sounds by inexperienced users. The multi-sensor array is based on a flexible Printed Circuit Board mounting 48 microphones with a high spatial resolution, three electrodes to record an ECG and a Magneto-Inertial Measurement Unit. We validated the usability over a sample population of 42 inexperienced volunteers and found that all subjects could record signals of good to excellent quality. Moreover, we found that the multi-sensor array is suitable for use on a wide population of at-risk patients regardless of their body characteristics. Based on the promising findings of this study, we believe that the described device could enable the home monitoring of CHF patients soon.

Verified
Journal Article
Open access
PDF file
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
SRSamanta Rosati
Samanta Rosati
SCSabrina De Cillis
Sabrina De Cillis
NGNoemi Giordano
Noemi Giordano
GVGabriele Volpi
Gabriele Volpi
FPFrancesco Porpiglia
Francesco Porpiglia
The aim of this study is to present a personalized predictive model (PPM) with a machine learning (ML) system that is able to identify and classify patients with suspected prostate cancer (PCa) following mpMRI. We extracted all the patients who underwent fusion biopsy (FB) from March 2014 to December 2019, while patients from August 2020 to April 2021 were included as a validation set. The proposed system was based on the following four ML methods: a fuzzy inference system (FIS), the support vector machine (SVM), k-nearest neighbors (KNN), and self-organizing maps (SOMs). Then, a system based on fuzzy logic (FL) + SVM was compared with logistic regression (LR) and standard diagnostic tools. A total of 1448 patients were included in the training set, while 181 patients were included in the validation set. The area under the curve (AUC) of the proposed FIS + SVM model was comparable with the LR model but outperformed the other diagnostic tools. The FIS + SVM model demonstrated the best performance, in terms of negative predictive value (NPV), on the training set (78.5%); moreover, it outperformed the LR in terms of specificity (92.1% vs. 83%). Considering the validation set, our model outperformed the other methods in terms of NPV (60.7%), sensitivity (90.8%), and accuracy (69.1%). In conclusion, we successfully developed and validated a PPM tool using the FIS + SVM model to calculate the probability of PCa prior to a prostate FB, avoiding useless ones in 15% of the cases.

1 July 2019
Verified
Conference Paper
Closed access
NGNoemi Giordano
Noemi Giordano
MKMarco Knaflitz
Marco Knaflitz
Phonocardiography (PCG) is a promising tool for the diagnosis and follow-up of cardiovascular diseases. To date it is available only in clinical settings, because it relies on an experienced examiner for the positioning of the electronic stethoscope. Making it possible for an unexperienced user to obtain high quality PCG signals would allow for developing instruments suitable for homecare purposes. In this work, we test the usage of three standardly positioned microphone probes. The aim is to compare two different approaches for enhancing the PCG signal quality, namely a) selecting the single source with the highest Signal-to-Noise Ratio (SNR) and b) combining the three sources through array signal processing techniques. Both approaches were tested on a sample population counting 24 healthy subjects. We found that the two approaches above give statistically different results (two-tailed paired t-test, p = 0.037) in terms of SNR of the enhanced signal. Specifically, selecting the single source with highest SNR gives, on average, the best results. Moreover, this approach is also associated with the lowest computational cost. Finally, for every subject of our sample population, we obtained SNR values higher than 12.5 dB on the enhanced signal, which we consider as sufficient for the application of heart sound segmentation and classification algorithms. We believe that this methodology allows for obtaining PCG signals of sufficient quality for the analysis of heart sounds, thus opening to the applicability of PCG in a homecare context.