Gabriella Balestra

Dr. Gabriella Balestra

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
SRSamanta Rosati
Samanta Rosati
GBGabriella Balestra
Gabriella Balestra
MKMarco KNAFLITZ
Marco KNAFLITZ
Human Activity Recognition (HAR) refers to an emerging area of interest for medical, military, and security applications. However, the identification of the features to be used for activity classification and recognition is still an open point. The aim of this study was to compare two different feature sets for HAR. Particularly, we compared a set including time, frequency, and time-frequency domain features widely used in literature (FeatSet_A) with a set of time-domain features derived by considering the physical meaning of the acquired signals (FeatSet_B). The comparison of the two sets were based on the performances obtained using four machine learning classifiers. Sixty-one healthy subjects were asked to perform seven different daily activities wearing a MIMU-based device. Each signal was segmented using a 5-s window and for each window, 222 and 221 variables were extracted for the FeatSet_A and FeatSet_B respectively. Each set was reduced using a Genetic Algorithm (GA) simultaneously performing feature selection and classifier optimization. Our results showed that Support Vector Machine achieved the highest performances using both sets (97.1% and 96.7% for FeatSet_A and FeatSet_B respectively). However, FeatSet_B allows to better understand alterations of the biomechanical behavior in more complex situations, such as when applied to pathological subjects.

7 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
NGNoemi Giordano
Noemi Giordano
SRSamanta Rosati
Samanta Rosati
GBGabriella Balestra
Gabriella Balestra
MKMarco KNAFLITZ
Marco KNAFLITZ
The home monitoring of patients affected by chronic heart failure (CHF) is of key importance in preventing acute episodes. Nevertheless, no wearable technological solution exists to date. A possibility could be offered by Cardiac Time Intervals extracted from simultaneous recordings of electrocardiographic (ECG) and phonocardiographic (PCG) signals. Nevertheless, the recording of a good-quality PCG signal requires accurate positioning of the stethoscope over the chest, which is unfeasible for a naïve user as the patient. In this work, we propose a solution based on multi-source PCG. We designed a flexible multi-sensor array to enable the recording of heart sounds by inexperienced users. The multi-sensor array is based on a flexible Printed Circuit Board mounting 48 microphones with a high spatial resolution, three electrodes to record an ECG and a Magneto-Inertial Measurement Unit. We validated the usability over a sample population of 42 inexperienced volunteers and found that all subjects could record signals of good to excellent quality. Moreover, we found that the multi-sensor array is suitable for use on a wide population of at-risk patients regardless of their body characteristics. Based on the promising findings of this study, we believe that the described device could enable the home monitoring of CHF patients soon.

28 April 2023 in IEEE Open Journal of Engineering in Medicine and Biology
Verified
Journal Article
Open access
JPJovana Panic
Jovana Panic
ADArianna Defeudis
Arianna Defeudis
GBGabriella Balestra
Gabriella Balestra
Valentina GianniniValentina Giannini
Valentina Giannini
SRSamanta Rosati
Samanta Rosati
Goal: Artificial intelligence applied to medical image analysis has been extensively used to develop non-invasive diagnostic and prognostic signatures. However, these imaging biomarkers should be largely validated on multi-center datasets to prove their robustness before they can be introduced into clinical practice. The main challenge is represented by the great and unavoidable image variability which is usually addressed using different pre-processing techniques including spatial, intensity and feature normalization. The purpose of this study is to systematically summarize normalization methods and to evaluate their correlation with the radiomics model performances through meta-analyses. This review is carried out according to the PRISMA statement: 4777 papers were collected, but only 74 were included. Two meta-analyses were carried out according to two clinical aims: characterization and prediction of response. Findings of this review demonstrated that there are some commonly used normalization approaches, but not a commonly agreed pipeline that can allow to improve performance and to bridge the gap between bench and bedside.

8 June 2024 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
YZYanhua Zhang
Yanhua Zhang
GBGabriella Balestra
Gabriella Balestra
KZKe Zhang
Ke Zhang
JWJingyu Wang
Jingyu Wang
SRSamanta Rosati
Samanta Rosati
Valentina GianniniValentina Giannini
Valentina Giannini

17 July 2023 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
Valentina GianniniValentina Giannini
Valentina Giannini
JPJovana Panic
Jovana Panic
DRDaniele Regge
Daniele Regge
GBGabriella Balestra
Gabriella Balestra
SRSamanta Rosati
Samanta Rosati
Radiomics-based systems could improve the management of oncological patients by supporting cancer diagnosis, treatment planning, and response assessment. However, one of the main limitations of these systems is the generalizability and reproducibility of results when they are applied to images acquired in different hospitals by different scanners. Normalization has been introduced to mitigate this issue, and two main approaches have been proposed: one rescales the image intensities (image normalization), the other the feature distributions for each center (feature normalization). The aim of this study is to evaluate how different image and feature normalization methods impact the robustness of 93 radiomics features acquired using a multicenter and multi-scanner abdominal Magnetic Resonance Imaging (MRI) dataset. To this scope, 88 rectal MRIs were retrospectively collected from 3 different institutions (4 scanners), and for each patient, six 3D regions of interest on the obturator muscle were considered. The methods applied were min-max, 1st-99th percentiles and 3-Sigma normalization, z-score standardization, mean centering, histogram normalization, Nyul-Udupa and ComBat harmonization. The Mann-Whitney U-test was applied to assess features repeatability between scanners, by comparing the feature values obtained for each normalization method, including the case in which no normalization was applied. Most image normalization methods allowed to reduce the overall variability in terms of intensity distributions, while worsening or showing unpredictable results in terms of feature robustness, except for the z-score, which provided a slight improvement by increasing the number of statistically similar features from 9/93 to 10/93. Conversely, feature normalization methods positively reduced the overall variability across the scanners, in particular, 3sigma, z_score and ComBat that increased the number of similar features (79/93). According to our results, it emerged that none of the image normalization methods was able to strongly increase the number of statistically similar features.

Verified
Journal Article
Open access
PDF file
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
SRSamanta Rosati
Samanta Rosati
SCSabrina De Cillis
Sabrina De Cillis
NGNoemi Giordano
Noemi Giordano
GVGabriele Volpi
Gabriele Volpi
FPFrancesco Porpiglia
Francesco Porpiglia
The aim of this study is to present a personalized predictive model (PPM) with a machine learning (ML) system that is able to identify and classify patients with suspected prostate cancer (PCa) following mpMRI. We extracted all the patients who underwent fusion biopsy (FB) from March 2014 to December 2019, while patients from August 2020 to April 2021 were included as a validation set. The proposed system was based on the following four ML methods: a fuzzy inference system (FIS), the support vector machine (SVM), k-nearest neighbors (KNN), and self-organizing maps (SOMs). Then, a system based on fuzzy logic (FL) + SVM was compared with logistic regression (LR) and standard diagnostic tools. A total of 1448 patients were included in the training set, while 181 patients were included in the validation set. The area under the curve (AUC) of the proposed FIS + SVM model was comparable with the LR model but outperformed the other diagnostic tools. The FIS + SVM model demonstrated the best performance, in terms of negative predictive value (NPV), on the training set (78.5%); moreover, it outperformed the LR in terms of specificity (92.1% vs. 83%). Considering the validation set, our model outperformed the other methods in terms of NPV (60.7%), sensitivity (90.8%), and accuracy (69.1%). In conclusion, we successfully developed and validated a PPM tool using the FIS + SVM model to calculate the probability of PCa prior to a prostate FB, avoiding useless ones in 15% of the cases.