Kok Beng Gan

Dr. Kok Beng Gan

Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, Kuala Selangor, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Ali F. AlmutairiAli F. Almutairi
Ali F. Almutairi
Kok Beng GanKok Beng Gan
Kok Beng Gan
NMNORBAHIAH BINTI MISRAN
NORBAHIAH BINTI MISRAN
Nowshad AminNowshad Amin
Nowshad Amin
Internet of Things (IoT) based healthcare system is now at the top peak because of its potentialities among all other IoT applications. Supporting sensors integrated with IoT healthcare can effectively analyze and gather the patients’ physical health data that has made the IoT based healthcare ubiquitously acceptable. A set of challenges including the continuous presence of the healthcare professionals and staff as well as the proper amenities in remote areas during emergency situations need to be addressed for developing a flexible IoT based healthcare system. Besides that, the human entered data are not as reliable as automated generated data. The development of the IoT based health monitoring system allows a personalized treatment in certain circumstances that helps to reduce the healthcare cost and wastage with a continuous improving outcome. We present an IoT based health monitoring system using the MySignals development shield with (Low power long range) LoRa wireless network system. Electrocardiogram (ECG) sensor, body temperature sensor, pulse rate, and oxygen saturation sensor have been used with MySignals and LoRa. Evaluating the performances and effectiveness of the sensors and wireless platform devices are also analyzed in this paper by applying physiological data analysis methodology and statistical analysis. MySignals enables the stated sensors to gather physical data. The aim is to transmit the gathered data from MySignals to a personal computer by implementing a wireless system with LoRa. The results show that MySignals is successfully interfaced with the ECG, temperature, oxygen saturation, and pulse rate sensors. The communication with the hyper-terminal program using LoRa has been implemented and an IoT based healthcare system is being developed in MySignals platform with the expected results getting from the sensors.

6 April 2020 in IEEE Access
Verified
Journal Article
Open access
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
MSMd Samsuzzaman Sobuz
Md Samsuzzaman Sobuz
Kok Beng GanKok Beng Gan
Kok Beng Gan
NMNORBAHIAH BINTI MISRAN
NORBAHIAH BINTI MISRAN
Nowshad AminNowshad Amin
Nowshad Amin
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
A gap coupled hexagonal split ring resonator (GCHSRR) based metamaterial is presented in this paper for S-band and X-band microwave applications with absorptance. This gap coupled hexagonal split ring resonator is the amendment of the typical split-ring resonator (SRR). Three interconnected hexagonal split ring resonators are applied with a stripline to increase the electrical length and coupling effect of the GCHSRR. SRR has an impact on the extraction of effective parameters such as permittivity, permeability and refractive index. The dimension of the proposed GCHSRR unit cell is 10×10 mm2, which is printed on low-cost FR4 material. The transmission frequency of the proposed GCHSRR unit cell ranges from 3.42 GHz to 3.73 GHz and 11.27 GHz to 11.91 GHz, which makes the metamaterial applicable for S-band and X-band microwave applications. The GCHSRR unit cell has a double negative regime of 7.92 GHz to 9.78 GHz with an effective negative refractive index regime of 6.30 GHz to 10.22 GHz and 11.97 GHz to 12.61 GHz. The effective medium ratio is 8.4, which implies the novelty of the proposed design. Moreover, the GCHSRR has high absorption peaks of 99%, 98%, and 81% at 4.27 GHz, 5.42 GHz, and 12.40 GHz, respectively. An 18×20 GCHSRR array structure is also designed and studied. The effective parameters and the effective medium ratio with a high absorptance make the proposed GCHSRR based metamaterial suitable for practical microwave applications.

18 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CHChang Soon Tony Hii
Chang Soon Tony Hii
Kok Beng GanKok Beng Gan
Kok Beng Gan
NZNasharuddin Bin Zainal
Nasharuddin Bin Zainal
NINorlinah Mohamed Ibrahim
Norlinah Mohamed Ibrahim
SAShahrul Azmin
Shahrul Azmin
HYHuay Woon You
Huay Woon You
Gait analysis is an essential tool for detecting biomechanical irregularities, designing personalized rehabilitation plans, and enhancing athletic performance. Currently, gait assessment depends on either visual observation, which lacks consistency between raters and requires clinical expertise, or instrumented evaluation, which is costly, invasive, time-consuming, and requires specialized equipment and trained personnel. Markerless gait analysis using 2D pose estimation techniques has emerged as a potential solution, but it still requires significant computational resources and human involvement, making it challenging to use. This research proposes an automated method for temporal gait analysis that employs the MediaPipe Pose, a low-computational-resource pose estimation model. The study validated this approach against the Vicon motion capture system to evaluate its reliability. The findings reveal that this approach demonstrates good (ICC(2,1) > 0.75) to excellent (ICC(2,1) > 0.90) agreement in all temporal gait parameters except for double support time (right leg switched to left leg) and swing time (right), which only exhibit a moderate (ICC(2,1) > 0.50) agreement. Additionally, this approach produces temporal gait parameters with low mean absolute error. It will be useful in monitoring changes in gait and evaluating the effectiveness of interventions such as rehabilitation or training programs in the community.

21 February 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
AHAmran Hossain
Amran Hossain
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Tawsifur RahmanTawsifur Rahman
Tawsifur Rahman
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
ATAnas Tahir
Anas Tahir
MSMohamed S. Soliman
Mohamed S. Soliman
Automated brain tumor segmentation from reconstructed microwave (RMW) brain images and image classification is essential for the investigation and monitoring of the progression of brain disease. The manual detection, classification, and segmentation of tumors are extremely time-consuming but crucial tasks due to the tumor’s pattern. In this paper, we propose a new lightweight segmentation model called MicrowaveSegNet (MSegNet), which segments the brain tumor, and a new classifier called the BrainImageNet (BINet) model to classify the RMW images. Initially, three hundred (300) RMW brain image samples were obtained from our sensors-based microwave brain imaging (SMBI) system to create an original dataset. Then, image preprocessing and augmentation techniques were applied to make 6000 training images per fold for a 5-fold cross-validation. Later, the MSegNet and BINet were compared to state-of-the-art segmentation and classification models to verify their performance. The MSegNet has achieved an Intersection-over-Union (IoU) and Dice score of 86.92% and 93.10%, respectively, for tumor segmentation. The BINet has achieved an accuracy, precision, recall, F1-score, and specificity of 89.33%, 88.74%, 88.67%, 88.61%, and 94.33%, respectively, for three-class classification using raw RMW images, whereas it achieved 98.33%, 98.35%, 98.33%, 98.33%, and 99.17%, respectively, for segmented RMW images. Therefore, the proposed cascaded model can be used in the SMBI system.

29 August 2013 in SpringerPlus
Verified
Journal Article
Open access
PDF file
DADhifaf Azeez
Dhifaf Azeez
MAMohd Alauddin Mohd Ali
Mohd Alauddin Mohd Ali
Kok Beng GanKok Beng Gan
Kok Beng Gan
ISIsmail Saiboon
Ismail Saiboon
Unexpected disease outbreaks and disasters are becoming primary issues facing our world. The first points of contact either at the disaster scenes or emergency department exposed the frontline workers and medical physicians to the risk of infections. Therefore, there is a persuasive demand for the integration and exploitation of heterogeneous biomedical information to improve clinical practice, medical research and point of care. In this paper, a primary triage model was designed using two different methods: an adaptive neuro-fuzzy inference system (ANFIS) and artificial neural network (ANN).When the patient is presented at the triage counter, the system will capture their vital signs and chief complains beside physiology stat and general appearance of the patient. This data will be managed and analyzed in the data server and the patient’s emergency status will be reported immediately. The proposed method will help to reduce the queue time at the triage counter and the emergency physician’s burden especially duringdisease outbreak and serious disaster. The models have been built with 2223 data set extracted from the Emergency Department of the Universiti Kebangsaan Malaysia Medical Centre to predict the primary triage category. Multilayer feed forward with one hidden layer having 12 neurons has been used for the ANN architecture. Fuzzy subtractive clustering has been used to find the fuzzy rules for the ANFIS model. The results showed that the RMSE, %RME and the accuracy which evaluated by measuring specificity and sensitivity for binary classificationof the training data were 0.14, 5.7 and 99 respectively for the ANN model and 0.85, 32.00 and 96.00 respectively for the ANFIS model. As for unseen data the root mean square error, percentage the root mean square error and the accuracy for ANN is 0.18, 7.16 and 96.7 respectively, 1.30, 49.84 and 94 respectively for ANFIS model. The ANN model was performed better for both training and unseen data than ANFIS model in term of generalization. It was therefore chosen as the technique to develop the primary triage prediction model. This primary triage model will be combined with the secondary triage prediction model to produce the final triage category as a tool to assist the medical officer in the emergency department.

28 April 2009 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Kok Beng GanKok Beng Gan
Kok Beng Gan
EZEdmond Zahedi
Edmond Zahedi
MAMohd. Alauddin Mohd Ali
Mohd. Alauddin Mohd Ali
In obstetrics, fetal heart rate (FHR) detection remains the standard for intrapartum assessment of fetal well-being. In this paper, a low-power (<55 mW) optical technique is proposed for transabdominal FHR detection using near-infrared photoplesthysmography (PPG). A beam of IR-LED (890 nm) propagates through to the maternal abdomen and fetal tissues, resulting in a mixed signal detected by a low-noise detector situated at a distance of 4 cm. Low-noise amplification and 24-bit analog-to-digital converter resolution ensure minimum effect of quantization noise. After synchronous detection, the mixed signal is processed by an adaptive filter to extract the fetal signal, whereas the PPG from the mother's index finger is the reference input. A total of 24 datasets were acquired from six subjects at 37 plusmn 2 gestational weeks. Results show a correlation coefficient of 0.96 (p-value < 0.001) between the proposed optical and ultrasound FHR, with a maximum error of 4%. Assessment of the effect of probe position on detection accuracy indicates that the probe should be close to fetal tissues, but not necessarily restricted to head or buttocks.