Martin Larivière-Bastien

Dr. Martin Larivière-Bastien


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2024 in Proceedings of the Combustion Institute
Verified
Journal Article
Open access
PLPaule Lapeyre
Paule Lapeyre
NNNishant Sriram Narayanan
Nishant Sriram Narayanan
MLMartin Larivière-Bastien
Martin Larivière-Bastien
KDKyle J. Daun
Kyle J. Daun
In recent years, quantifying flare emissions has assumed new significance due to their impact on climate change and human health. Imaging Fourier transform spectrometers (IFTSs) operating over the infrared spectrum are a particularly promising avenue for this task since they can directly visualize the species column density contained within the entire flare plume via the absorption features of these species. These instruments generate a datacube of images, each pertaining to a unique wavelength. Spectroscopic and velocity submodels are then used to obtain the species mass flow rates needed to calculate the CE. This work compares the performance of mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) IFTSs for measuring the CE for flares at petrochemical refineries, and, for the first time, uses a LWIR IFTS to fingerprint the plume species and estimate the CE. While the detection spectrum of the MWIR camera includes prominent CO2 features, the limited dynamic range of the camera leads to lens flare artifacts from the combustion zone that bias quantification of this species in the plume, thereby affecting the CE estimates. Images from the LWIR camera, in contrast, are free of these artifacts, and the dynamic range is sufficient to measure both CO2 and unburned fuel, key to accurate CE estimates.

8 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
JSJames Stofel
James Stofel
KWKody A Wilson
Kody A Wilson
MLMartin Larivière-Bastien
Martin Larivière-Bastien
AFAnthony Franz
Anthony Franz
MDMichael Dexter
Michael Dexter
Capturing reliable hyperspectral imager data at a meaningful frame rate for explosions and other fast-changing scenes is not possible in the mid-wave infrared region under traditional sensor operating configurations and processing techniques, which typically have frame rates on the order of 0.5–2.0 Hz. To combat these shortcomings, the scene acquisition parameters were tailored for explosions and a new method for processing optical signatures of fast transient scenes with Fourier-transform infrared hyperspectral imagers was developed. For this technique, the instrument was first configured to collect asymmetric interferograms while optimizing the number of measurement points on the short side of the interferogram. Additionally, pixel-wise zero path distance offset and phase corrections were applied to the interferograms, a reduced spectral resolution of 8 cm−1 was selected, and the window size was narrowed to 32 × 64 pixels while using a lens with a wide field of view. The smooth offset correction for scene change artifacts was then applied in post-processing to address any remaining artifacts in the Fourier-transformed spectra. These procedures yielded a 29× increase in frame rate and significant improvements in spectra fidelity. This work makes reliable field calibrations and measurements of explosions with Fourier-transform infrared hyperspectral imagers more achievable than before.

13 September 2021 in Pomiary Automatyka Robotyka
Verified
Journal Article
Closed access
MKMariusz Kastek
Mariusz Kastek
KFKrzysztof Firmanty
Krzysztof Firmanty
BSBenjamin Saute
Benjamin Saute
PGPhilippe Gagnon
Philippe Gagnon
MLMartin Larivière-Bastien
Martin Larivière-Bastien
DPDaniel Pawelski
Daniel Pawelski
Detection, identification, and quantification of greenhouse gases is essential to ensure compliance with regulatory guidelines and mitigate damage associated with anthropogenic climate change. Passive infrared hyperspectral imaging technology is among the solutions that can detect, identify and quantify multiple greenhouse gases simultaneously. The Telops Hyper-Cam Airborne Platform is an established system for aerial thermal infrared hyperspectral measurements for gas survey applications. In support of the Hypercam, is developing a suite of hyperspectral imaging data processing algorithms that allow for gas detection, identification, and quantification in real-time. In the Fall of 2020, the Hyper-Cam-LW Airborne platform was flown above a validated SF6 gas release system to collect hyperspectral data for gas quantification analysis. This measurement campaign was performed to document performance of the Hyper-Cam gas quantification capabilities against known quantities of released gas.

8 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SMSina Talebi Moghaddam
Sina Talebi Moghaddam
MLMartin Larivière-Bastien
Martin Larivière-Bastien
MCMartin Chamberland
Martin Chamberland
KDKyle Daun
Kyle Daun
This study describes the development and evaluation of an algorithm for retrieving methane (CH4) column densities and emission rates from airborne long-wavelength infrared (LWIR) hyperspectral imagery. The algorithm was validated through controlled-release experiments conducted over both bare ground and snow-covered surfaces. Methane plumes were detected using k-means clustering-based segmentation integrated with a clutter-matched filter (CMF), while a modified autonomous atmospheric compensation (AAC) framework was used to account for the air mass between the plume and the sensor, as well as surface heterogeneities. Atmospheric estimates derived from this framework were incorporated into a spectroscopic inversion to retrieve CH4 column densities for each pixel, which were then combined with local wind measurements to obtain emission rate estimates. The results indicated a generally strong correlation between the inferred and actual emission rates; however, significant variability was observed in the inferred data. This variability can largely be attributed to several factors, including low thermal contrast in certain images, non-grey background emissivities, and notably, the wind speed values used to estimate emission rates. These findings emphasize the capability of airborne LWIR hyperspectral imaging as a scalable method for methane monitoring, while also highlighting the critical need for thorough characterization of uncertainties in emission retrieval processes.