Kody A Wilson

Mr. Kody A Wilson


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2022 in The Journal of the Astronautical Sciences
Verified
Journal Article
Closed access
PDF file
EAEthan M. Albrecht
Ethan M. Albrecht
AJAudra M. Jensen
Audra M. Jensen
EJErik G. Jensen
Erik G. Jensen
KWKody A Wilson
Kody A Wilson
MPMichael K. Plummer
Michael K. Plummer
CSCasey P. Schuetz-Christy
Casey P. Schuetz-Christy

19 March 2025 in Applied Optics
Verified
Journal Article
Closed access
KWKody A Wilson
Kody A Wilson
CRCovadonga Diaz Ruiz
Covadonga Diaz Ruiz
SYShannon R. Young
Shannon R. Young
MDMichael Dexter
Michael Dexter
AFAnthony Franz
Anthony Franz
Fourier transform spectroscopy is commonly used to measure spectra because of its accuracy and versatility. When the irradiance changes in the field of view (FOV), the spectra are contaminated by the scene change artifacts (SCAs). SCAs caused by an oscillatory obscuration affecting multiple target spectra were examined through simulations and experiments. This work demonstrates that SCAs are hundreds of times larger than the spectra. These SCAs are dependent on the oscillation phase and appear in the real and imaginary parts of the spectra. The recombobulate correction method (RCM) is introduced, which removes SCAs by separating interferogram points into target and background interferograms. RCM demonstrated a 99% reduction in spectral SCAs. Future work will address other non-oscillatory SCAs.

17 January 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
KWKody A Wilson
Kody A Wilson
MDMichael Dexter
Michael Dexter
Benjamin AkersBenjamin Akers
Benjamin Akers
AFAnthony Franz
Anthony Franz
Fourier-transform spectrometers are widely used for spectral measurements. Changes in the field of view during measurement introduce oscillations into the measured spectra known as scene-change artifacts. Field-of-view changes also introduce uncertainty about which target the measured spectrum represents. Though scene-change artifacts are often present in dynamic data, their significance is disputed in the current literature. This work presents a theoretical framework and experimental validation for scene-change artifacts. Field-of-view changes introduce variable interferogram offsets, which standard processing techniques assume are constant. The error between the interferogram offset and its estimate is Fourier-transformed, yielding scene-change artifacts, often confused with noise, in the calibrated spectrum. Previous theoretical models ignored the effect of the interferogram offset in generating SCAs, leading to an underestimation of the scene-change artifact significance. Smooth offset correction removes these artifacts by estimating the variable interferogram offset using locally weighted scatter-plot smoothing. Updating the interferogram offset estimate resulted in the same accuracy expected for static conditions. The resulting spectra resemble the zero path difference spectra, similar to earlier theoretical predictions. These results indicate that Fourier-transform spectroscopy accuracy with variable scenes can be significantly improved with minor modifications to data processing.

18 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
KWKody A Wilson
Kody A Wilson
MDMichael Dexter
Michael Dexter
Benjamin AkersBenjamin Akers
Benjamin Akers
AFAnthony Franz
Anthony Franz
Fourier-transform spectroscopy is a widely used technique for determining the spectral and thermal properties of a target. However, target temperature variations during measurement can compromise the spectral accuracy. Temperature fluctuations induce oscillations superimposed on the target spectrum. These oscillations, referred to as scene-change artifacts, degrade the spectral accuracy. The literature is divided, with theoretical predictions suggesting negligible artifacts and growing experimental evidence reporting significant artifacts. This paper presents a theory and experimental validation of scene-change artifacts originating from target temperature variations. Traditionally, the interferogram offset is assumed to be constant, an invalid assumption for a changing scene. The error is subsequently Fourier-transformed, producing scene-change artifacts. Accurately estimating the truth spectrum is often challenging. To address this, we propose the signal-to-scene-change-artifact ratio, a metric that quantifies the impact of scene-change artifacts without knowledge of the truth spectrum. The artifacts will be eliminated by estimating the interferogram offset using smooth offset correction. Furthermore, the interferogram offset enables determination of the target’s temperature with a greater accuracy and an increased temporal resolution compared to using the spectra. These results will demonstrate that a smooth offset correction can improve the spectrum and temperature accuracy on thermally variant targets when measured with a Fourier-transform spectrometer.

12 May 2015
Verified
Conference Paper
Closed access
PDF file
HKHans G. Korth
Hans G. Korth
KWKody A Wilson
Kody A Wilson
KGKevin C. Gross
Kevin C. Gross
MHMichael R. Hawks
Michael R. Hawks
TZTimothy W. C. Zens
Timothy W. C. Zens

8 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
JSJames Stofel
James Stofel
KWKody A Wilson
Kody A Wilson
MLMartin Larivière-Bastien
Martin Larivière-Bastien
AFAnthony Franz
Anthony Franz
MDMichael Dexter
Michael Dexter
Capturing reliable hyperspectral imager data at a meaningful frame rate for explosions and other fast-changing scenes is not possible in the mid-wave infrared region under traditional sensor operating configurations and processing techniques, which typically have frame rates on the order of 0.5–2.0 Hz. To combat these shortcomings, the scene acquisition parameters were tailored for explosions and a new method for processing optical signatures of fast transient scenes with Fourier-transform infrared hyperspectral imagers was developed. For this technique, the instrument was first configured to collect asymmetric interferograms while optimizing the number of measurement points on the short side of the interferogram. Additionally, pixel-wise zero path distance offset and phase corrections were applied to the interferograms, a reduced spectral resolution of 8 cm−1 was selected, and the window size was narrowed to 32 × 64 pixels while using a lens with a wide field of view. The smooth offset correction for scene change artifacts was then applied in post-processing to address any remaining artifacts in the Fourier-transformed spectra. These procedures yielded a 29× increase in frame rate and significant improvements in spectra fidelity. This work makes reliable field calibrations and measurements of explosions with Fourier-transform infrared hyperspectral imagers more achievable than before.