Michael Dexter

Prof. Dr. Michael Dexter

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2025 in Applied Optics
Verified
Journal Article
Closed access
PDF file
APAnil K. Patnaik
Anil K. Patnaik
MDMichael Dexter
Michael Dexter
KFKyle D. Frische
Kyle D. Frische
BKBenjamin M. Knight
Benjamin M. Knight
NTNathaniel Tamminga
Nathaniel Tamminga
ECEnam Chowdhury
Enam Chowdhury
Ultra-intense laser and plasma interactions with their ability to accelerate particles reaching relativistic speed are exciting from a fundamental high-field physics perspective. Such relativistic laser-plasma interaction (RLPI) offers a plethora of critical applications for energy, space, and defense enterprise. At AFIT’s Extreme Light Laboratory (ELL), we have demonstrated such RLPI employing a table-top ∼10mJ, 40 fs laser pulses at a kHz repetition rate that produce different types of secondary radiations via target normal sheath acceleration (TNSA). With our recent demonstration of laser-driven fusion, the secondary radiations generated are neutrons, x-ray emission, and MeV energy electrons and protons—all at a kHz rate. To achieve the high repetition rate, we developed the enabling kHz-repetition-rate-compatible liquid targets in the form of microjets, droplets, and submicron-thick sheets. These targets, combined with high repetition rate diagnostics, enable a unique, real-time feedback loop between the experimental inputs (laser and target parameters) and generated sources (x-rays, electrons, ions, etc.) to develop machine learning (ML)-based control of mixed radiation. The goal of this paper is to provide an overview of the capabilities of ELL, describe the diagnostics and characteristics of the secondary radiation, data analysis, and quasi-real-time ML functionality of this platform that have been developed over the last decade and a half.

1 June 2025 in APL Machine Learning
Verified
Journal Article
Open access
NTNathaniel Tamminga
Nathaniel Tamminga
SFScott Feister
Scott Feister
KFKyle D. Frische
Kyle D. Frische
RDRonak Desai
Ronak Desai
JSJoseph Snyder
Joseph Snyder
APAnil K. Patnaik
Anil K. Patnaik
Ultra-intense laser–matter interactions are often difficult to predict from first principles because of the complexity of plasma processes and the many degrees of freedom relating to the laser and target parameters. An important approach to controlling and optimizing ultra-intense laser interactions involves gathering large datasets and using these data to train statistical and machine learning models. In this paper, we describe experimental efforts to accelerate electrons and protons to ∼MeV energies with this goal in mind. These experiments involve a 1 kHz repetition rate ultra-intense laser system with ∼10 mJ per shot, a peak intensity near 5 × 1018 W/cm2, and a “liquid leaf” target. Improvements to the data acquisition capabilities of this laser system greatly aided this investigation. Generally, we find that the trained models were very effective in controlling the numbers of MeV electrons ejected. The models were less successful at shifting the energy range of ejected electrons. Simultaneous control of the numbers of ∼MeV electrons and the energy range will be the subject of future experimentation using this platform.

19 March 2025 in Applied Optics
Verified
Journal Article
Closed access
KWKody A Wilson
Kody A Wilson
CRCovadonga Diaz Ruiz
Covadonga Diaz Ruiz
SYShannon R. Young
Shannon R. Young
MDMichael Dexter
Michael Dexter
AFAnthony Franz
Anthony Franz
Fourier transform spectroscopy is commonly used to measure spectra because of its accuracy and versatility. When the irradiance changes in the field of view (FOV), the spectra are contaminated by the scene change artifacts (SCAs). SCAs caused by an oscillatory obscuration affecting multiple target spectra were examined through simulations and experiments. This work demonstrates that SCAs are hundreds of times larger than the spectra. These SCAs are dependent on the oscillation phase and appear in the real and imaginary parts of the spectra. The recombobulate correction method (RCM) is introduced, which removes SCAs by separating interferogram points into target and background interferograms. RCM demonstrated a 99% reduction in spectral SCAs. Future work will address other non-oscillatory SCAs.

30 April 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
ASAaron Michael Schinder
Aaron Michael Schinder
SYShannon Young
Shannon Young
BSBryan Jeffrey Steward
Bryan Jeffrey Steward
MDMichael Dexter
Michael Dexter
AKAndrew Kondrath
Andrew Kondrath
RDRicardo Davila
Ricardo Davila
This paper describes the creation of a fast, deterministic, 3D fractal cloud renderer for the AFIT Sensor and Scene Emulation Tool (ASSET). The renderer generates 3D clouds by ray marching through a volume and sampling the level-set of a fractal function. The fractal function is distorted by a displacement map, which is generated using horizontal wind data from a Global Forecast System (GFS) weather file. The vertical windspeed and relative humidity are used to mask the creation of clouds to match realistic large-scale weather patterns over the Earth. Small-scale detail is provided by the fractal functions which are tuned to match natural cloud shapes. This model is intended to run quickly, and it can run in about 700 ms per cloud type. This model generates clouds that appear to match large-scale satellite imagery, and it reproduces natural small-scale shapes. This should enable future versions of ASSET to generate scenarios where the same scene is consistently viewed from both GEO and LEO satellites from multiple perspectives.

17 January 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
KWKody A Wilson
Kody A Wilson
MDMichael Dexter
Michael Dexter
Benjamin AkersBenjamin Akers
Benjamin Akers
AFAnthony Franz
Anthony Franz
Fourier-transform spectrometers are widely used for spectral measurements. Changes in the field of view during measurement introduce oscillations into the measured spectra known as scene-change artifacts. Field-of-view changes also introduce uncertainty about which target the measured spectrum represents. Though scene-change artifacts are often present in dynamic data, their significance is disputed in the current literature. This work presents a theoretical framework and experimental validation for scene-change artifacts. Field-of-view changes introduce variable interferogram offsets, which standard processing techniques assume are constant. The error between the interferogram offset and its estimate is Fourier-transformed, yielding scene-change artifacts, often confused with noise, in the calibrated spectrum. Previous theoretical models ignored the effect of the interferogram offset in generating SCAs, leading to an underestimation of the scene-change artifact significance. Smooth offset correction removes these artifacts by estimating the variable interferogram offset using locally weighted scatter-plot smoothing. Updating the interferogram offset estimate resulted in the same accuracy expected for static conditions. The resulting spectra resemble the zero path difference spectra, similar to earlier theoretical predictions. These results indicate that Fourier-transform spectroscopy accuracy with variable scenes can be significantly improved with minor modifications to data processing.

15 May 2025 in Applied Optics
Verified
Journal Article
Closed access
CCCollin A. Crego
Collin A. Crego
TSTyler R. Smith
Tyler R. Smith
SYShannon R. Young
Shannon R. Young
MDMichael Dexter
Michael Dexter
AFAnthony Franz
Anthony Franz
Fourier-transform (FT) spectrometer data must be calibrated using at least two reference sources to yield a target temperature. An experiment was performed with an ABB MR304 FTIR spectrometer to determine the best calibration method for data from its MCT (mercury–cadmium–telluride) and InSb (indium–antimonide) detectors at temperatures well above the reference temperatures (extrapolation), as well as to analyze the effects of mesh screens on the detector behavior and calibration quality. Four datasets were collected and plotted on radiance versus instrument response plots to analyze the detector behaviors and to test how well lower temperature points predicted higher temperature points with linear and quadratic fitting. It was determined that the MCT detector is quadratic for low wavenumbers at a low signal but otherwise linear, and that the InSb detector is linear for all wavenumbers. It was concluded that (1) mesh screens have a detrimental effect on calibration quality and (2) linear calibration is the better method for calibration, including extrapolation.