Bruce Bernacki

Bruce Bernacki


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Journal of Applied Remote Sensing
Verified
Journal Article
Open access
PDF file
TMTanya L. Myers
Tanya L. Myers
TJTimothy J. Johnson
Timothy J. Johnson
NGNeal B. Gallagher
Neal B. Gallagher
BBBruce Bernacki
Bruce Bernacki
TBToya N. Beiswenger
Toya N. Beiswenger
TDTyler O. Danby
Tyler O. Danby
In the last few decades, hyperspectral imaging (HSI) has evolved as a method for remote detection with many applications, including identification of plants, earthen materials, and natural events, such as fire or volcanic eruption.1 – 3 Typically, the spectral data within an individual pixel are exploited by comparing the reflected/emitted energy of the target substance(s) (as mitigated by intervening atmosphere) with those materials’ spectral characteristics, which are compiled in a separate spectral library.4,5 Many materials have been studied with HSI and some even studied in multiple phases; much of the early HSI work focused on gas-phase detection6,7 and a few studies also reported liquid-phase detection.8 – 10 More recent HSI studies, however, have focused on detection of solid materials, typically using reflected visible or near-infrared wavelengths.11,12 The solid-phase studies have grown at an exponential pace, particularly for vegetation13 – 15 as well as for rocks, minerals, and other geological specimens.11,16 – 19 To support these geological studies, the ASTER spectral library database, for example, has grown to include over 2300 spectra for a wide variety of materials including minerals, rocks, vegetation, soils, and manmade materials covering the wavelength range 0.4 to 15.4  μm.20 Thermal infrared (TIR) or longwave infrared (LWIR) sensors can measure known spectral features that correspond to the fundamental vibrational frequencies of interatomic bonds within common rock-forming minerals. Only a few of the geologically-based studies, however, have used TIR wavelengths, and these include the very early laboratory studies of Hunt and Salisbury, who showed that igneous,17 sedimentary,18 and metamorphic19 species, particularly sedimentary species such as silicates and carbonates,18 are readily detected by infrared reflectance spectroscopy. Many HSI studies followed in the 1980s and 1990s21 including, e.g., the first TIR imaging studies by Kahle et al.22 as well as several others. In many of these pioneering works, it was noted that minerals containing anion chemical moieties such as silicates,23 carbonates,24 phosphates,25 sulfates,26 or cations such as ammonium or uranyl27,28 are all known to display characteristically strong emission/reflectance features in the LWIR between 7 and 13  μm, making them amenable to such TIR detection.

2 June 2020 in Optical Engineering
Verified
Journal Article
Open access
PDF file
BBBruce Bernacki
Bruce Bernacki
TJTimothy J. Johnson
Timothy J. Johnson
TMTanya L. Myers
Tanya L. Myers
Spectroscopy, especially infrared absorption and reflectance spectroscopy, is a valuable tool to remotely detect and identify unknown gases,1 – 4 solids,5 – 7 and liquids.8,9 Identification of unknown spectra from library endmembers makes use of techniques such as matched filtering, generalized least squares, and mixture-tuned matched filtering.10 In all of these methods, it is necessary to have a spectrum of the unknown material in the library for reliable identification. Spectral libraries exist for the three phases of matter, with solid materials typically characterized using reflectance spectroscopy, and gases and liquids identified predominantly using absorption spectroscopy.10,11 Unlike gases, the ability to detect solids and liquids under various environmental conditions using spectroscopic techniques can be challenging since morphological phenomena such as layer thickness,12 substrate composition,13,14 or particle size15,16 are all known to affect the infrared reflectance, emission, and transmission spectra. Generating a spectral library with all the different morphological conditions would require an infinite number of measurements; modeling the solid or liquid spectrum to account for the different morphological conditions is thus preferred but requires both the real (n) and imaginary (k) optical constants of the complex refractive index where n∼=n(v)+ik(v).

12 September 2022 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
TMTanya L. Myers
Tanya L. Myers
BBBruce Bernacki
Bruce Bernacki
MWMichael J. Wilhelm
Michael J. Wilhelm
KJKarissa L. Jensen
Karissa L. Jensen
TJTimothy J. Johnson
Timothy J. Johnson
ABAshley Bradley
Ashley Bradley
This paper investigates the accuracy of deriving the composite optical constants of binary mixtures from only the complex indices of refraction of the neat materials. These optical constants enable the reflectance spectra of the binary mixtures to be modeled for multiple scenarios (e.g., different substrates, thicknesses, volume ratios), which is important for contact and standoff chemical detection. Using volume fractions, each mixture's complex index of refraction was approximated via three different mixing rules. To explore the impact of intermolecular interactions, these predictions are tested by experimental measurements for two representative sets of binary mixtures: (1) tributyl phosphate combined with n-dodecane, a non-polar medium, to represent mixtures which primarily interact via dispersion forces and (2) tributyl phosphate and 1-butanol to represent mixtures with polar functional groups that can also interact via dipole–dipole interactions, including hydrogen bonding. The residuals and the root-mean-square error between the experimental and calculated index values are computed and demonstrate that for miscible liquids in which the average geometry of the cross-interactions can be considered isotropic (e.g., dispersion), the refractive indices of the mixtures can be modeled using composite n and k values derived from volume fractions of the neat liquids. Conversely, in spectral regions where the geometry of the cross-interactions is more restricted and anisotropic (e.g., hydrogen bonding), the calculated n and k values vary from the measured values. The impact of these interactions on the reflectance spectra are then compared by modeling a thin film of the binary mixtures on an aluminum substrate using both the measured and the mathematically computed indices of refraction.

26 December 2012 in Optical Engineering
Verified
Journal Article
Open access
PDF file
MPMark C. Phillips
Mark C. Phillips
BBBruce Bernacki
Bruce Bernacki
Using infrared hyperspectral imaging, microscopy of small particles of the explosives compounds RDX, tetryl, and PETN with near diffraction-limited performance is demonstrated. The custom microscope apparatus includes an external cavity quantum cascade laser illuminator scanned over its tuning range of 9.13 to 10.53 μm in 4 s, coupled with a microbolometer focal plane array to record infrared transmission images. The hyperspectral microscopy technique is used to study the infrared absorption spectra of individual explosives particles, and demonstrate subnanogram detection limits.

26 October 2020 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
MPMark C. Phillips
Mark C. Phillips
SHSivanandan S. Harilal
Sivanandan S. Harilal
JYJeremy Yeak
Jeremy Yeak
RJR. Jason Jones
R. Jason Jones
SWSonia Wharton
Sonia Wharton
BBBruce Bernacki
Bruce Bernacki
A swept-wavelength external cavity quantum cascade laser (ECQCL) is used to perform standoff detection of combustion gases in a plume generated from an outdoor high-explosive (HE) open detonation. The swept-ECQCL system was located at a standoff distance of 830 m from a 41 kg charge of LX-14 (polymer-bonded high explosive) and was used to measure the infrared transmission/absorption through the post-detonation plume as it propagated through the beam path. The swept-ECQCL was operated continuously to record broadband absorption spectra at a 200 Hz rate over a spectral range from 2050 to 2230 cm−1 (4.48–4.88 μm). Fitting of measured spectra was used to determine time-resolved column densities of CO, CO2, H2O, and N2O. Analysis of visible video imagery was used to provide timing correlations and to estimate plume dimensions, from which gas mixing ratios were estimated. Measured emission factors and modified combustion efficiency show good agreement with previously reported values.

6 August 2024 in Optics Express
Verified
Journal Article
Closed access
SLSchuyler P. Lockwood
Schuyler P. Lockwood
BBBruce Bernacki
Bruce Bernacki
MWMichael J. Wilhelm
Michael J. Wilhelm
TMTanya L. Myers
Tanya L. Myers
TBTracy J. Baker
Tracy J. Baker
TJTimothy J. Johnson
Timothy J. Johnson
The effects of light scattering and refraction play significantly different roles for aerosols than for bulk materials, making it challenging to identify aerosolized chemicals using traditional spectral methods or spectral reference libraries. Due to a potentially infinite number of particle morphologies, sizes, and compositions, constructing a database of laboratory-measured aerosol spectra is not a practical solution. Here, as an alternative approach, the measured n/k optical vectors of two example organic materials (diethyl phthalate and D-mannitol) are used in combination with particle absorption / scattering theory (Mie theory and FDTD) and the Beer-Lambert law to generate a series of synthetic infrared transmission / scattered light spectra. The synthetic spectra show significant differences versus simple slab transmission spectra, even for small changes in particle size (e.g., 5 vs. 10 µm) for both single particles and ensembles, potentially serving as useful reference data for aerosol sensing. For spherical single particles with diameters of 1 to 10 µm, FDTD simulations predict changes in the magnitudes of spectral shifts and the shapes of the peaks vs. particle size with only small deviations from Mie theory predictions, yet reliably capture the direction of the shifts. Typical spectral peak shifts in the longwave infrared correspond to Δλ ∼0.20 µm (∼34 cm-1) when compared to corresponding slab transmission spectra. Additionally, synthetic spectra generated from the n/k values derived using two different methods (KBr pellet transmission and single-angle reflectance) are compared using the Mie theory model.