Eskandari Razieh

Dr. Eskandari Razieh


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2023 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
EREskandari Razieh
Eskandari Razieh
Mohamad SawanMohamad Sawan
Mohamad Sawan
Brain-machine interfaces (BMI) are widely adopted in neuroscience investigations and neural prosthetics, with sensing channel counts constantly increasing. These Investigations place increasing demands for high data rates and low-power implantable devices despite high tissue losses. The Impulse radio ultra- wideband (IR-UWB), a revived wireless technology for short-range radios, has been widely used in various applications. Since the requirements and solutions are application-oriented, in this review paper we focus on neural recording implants with high-data rates and ultra-low power requirements. We examine in detail the working principle, design methodology, performance, and implementations of different architectures of IR-UWB transceivers in a quantitative manner to draw a deep comparison and extract the bottlenecks and possible solutions concerning the dedicated application. Our analysis shows that current solutions rely on enhanced or combined modulation techniques to improve link margin. An in-depth study of prior-art publications that achieved Gbps data rates concludes that edge-combination architecture and non-coherent detectors are remarkable for transmitter and receiver, respectively. Although the aim to minimize power and improve data rate - defined as energy efficiency (pJ/b) - extending communication distance despite high tissue losses and limited power budget, good narrow-band interference (NBI) tolerance coexisted in the same frequency band of UWB systems, and compatibility with energy harvesting designs are among the critical challenges remained unsolved. Furthermore, we expect that the combination of artificial intelligence (AI) and the inherent advantages of UWB radios will pave the way for future improvements in BMIs.

2 October 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
EREskandari Razieh
Eskandari Razieh
Mohamad SawanMohamad Sawan
Mohamad Sawan
In this article, we present a novel approach for designing a low-power, low-area impulse radio ultra-wideband (IR-UWB) noncoherent receiver capable of achieving a data rate of 100 Mbps. Our proposed receiver demonstrates the ability to demodulate ON-OFF keying pulse streams across the entire lower frequency band defined by the Federal Communication Commission for UWB applications. The key components of the proposed receiver include a reconfigurable differential two-stage low-noise amplifier, a fully differential squarer, narrow-band interface rejection filters, and variable gain baseband amplifiers. These circuits work cohesively to ensure efficient signal reception and processing. To validate the performance of the proposed receiver, we implemented the design using TSMC 40-nm CMOS process technology. A short-range communication including a 1.5 cm tissue layer is tested utilizing a typical upconversion UWB transmitter fabricated in the same technology. Remarkably, the proposed receiver achieves a data rate of 100 Mbps with an impressively low energy efficiency of 78.8 pJ/b and occupies an area of 0.705 $\textrm{mm}^{2}$. The compact size, remarkable energy efficiency, and high data rate capabilities of the proposed receiver meet the stringent requirements of neural recording implants.

31 January 2025 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
HHHadi Hayati
Hadi Hayati
SASaeed Ghaneei Aarani
Saeed Ghaneei Aarani
MKMousa Karimi
Mousa Karimi
EREskandari Razieh
Eskandari Razieh
Mohamad SawanMohamad Sawan
Mohamad Sawan
Benoit GosselinBenoit Gosselin
Benoit Gosselin
This paper presents an impulse radio ultra-wideband (IR-UWB) transmitter (TX) designed for miniature multi-channel neural recording platforms in freely moving laboratory animals. We introduce a 5-bit data-to-time modulation technique utilizing a 5-cell capacitive array. This approach minimizes the data rate’s dependency on pulse repetition frequency, while significantly reducing power dissipation and simplifying the TX’s architecture. Measurement results with the TX fabricated in TSMC 65-nm standard CMOS technology show that the proposed circuit provides a linear time change in the pulsewidth with a time step of 84 ps in average for every least significant bit in the input. Furthermore, the entire circuit consumes only 422 µW from a 0.65-V supply. The proposed TX achieves a significantly low energy consumption of 1.05 pJ/bit at 400 Mbps in a 0.5-m transmission range. The fabricated circuit occupies 0.255 mm2 of die area including pads.

1 January 2026 in IEEE Sensors Reviews
Verified
Journal Article
Open access
IAIbrahim Alkhalifa
Ibrahim Alkhalifa
EREskandari Razieh
Eskandari Razieh
Mohamad SawanMohamad Sawan
Mohamad Sawan
Khaled Nabil SalamaKhaled Nabil Salama
Khaled Nabil Salama
Electrochemical biosensors are widely used for their small size, rapid response, and versatility, with techniques, such as chronoamperometry (CA) and voltammetry, at the forefront. A potentiostat applies an excitation waveform and measures the current flowing through electrochemical biosensors. Traditional potentiostat architectures consist of a control amplifier, a current sensing circuit, and an analog-to-digital converter. Recent advances have introduced new circuit designs and techniques that enhance performance and extend the range of applications. We highlight in this article recent developments in single-mode potentiostat designs optimized for CA, cyclic voltammetry (CV), and fast-scan cyclic voltammetry (FSCV). We also explore the emerging class of digital potentiostats, discussing their advantages and limitations. In addition, multimodal potentiostat designs, capable of simultaneously implementing multiple techniques, such as CA, CV, FSCV, square wave voltammetry, and differential pulse voltammetry, are reviewed. The strengths, challenges, and potential applications of these systems are discussed. Finally, we present future research directions to address key challenges, such as multichannel high-throughput, drug delivery integration, CMOS/microfluidics packaging, and electrode biofouling, with the ultimate goal of enabling continuous in vivo monitoring.

6 July 2026 in Electronics
Verified
Journal Article
Open access
PDF file
WZWenjun Zou
Wenjun Zou
EREskandari Razieh
Eskandari Razieh
Jie YangJie Yang
Jie Yang
Mohamad SawanMohamad Sawan
Mohamad Sawan
We present in this paper an ultra-low-power impulse radio ultra-wideband (IR-UWB) transmitter intended for short-range, highly energy-efficient, and compact silicon-area applications, such as implantable brain–computer interfaces (iBCIs). The proposed transmitter features effective spectrum tunability, enabling independent adjustments to both the center frequency and −10 dB bandwidth. Fabricated in TSMC 40 nm CMOS technology, the chip occupies a core area of just 0.001 mm2. Experimental results demonstrate an energy efficiency of 2.45 pJ/b across a data rate range of 10 to 200 Mbps. The peak-to-peak output voltage amplitude is approximately 310 mV when driving a 50 Ω load. Furthermore, in vitro wireless measurements demonstrate reliable through-tissue transmission at an implantation depth of 18 mm and achieve a distance range exceeding 0.8 m.

11 December 2025 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
EREskandari Razieh
Eskandari Razieh
MNMoustafa Nawito
Moustafa Nawito
MKMostafa Katebi
Mostafa Katebi
Udo KraushaarUdo Kraushaar
Udo Kraushaar
HRHarald Richter
Harald Richter
Mohamad SawanMohamad Sawan
Mohamad Sawan
We present in this paper an implantable closed-loop neuromodulation prototype system for type 2 diabetes (T2D) management, which leverages pancreatic electrophysiology as both a sensing and therapeutic modality. Among candidate biomarkers, the fraction of plateau phase (FOPP) emerges as a robust indicator of glucose dynamics. Hence, the neural interface is optimized for low-power measurement of the electrical activity of the beta-cells with high accuracy in direct readout mode and long-term monitoring in FOPP mode. The experimental framework was established using a perfused pancreas model, first in mice and then optimized for rats, with glucose-dependent signals captured via a custom 16-channel neural interface. Results confirmed the feasibility of extracting FOPP in ex vivo settings, though signal complexity differed from isolated islets in vitro. Additionally, a fabricated 8-channel electrical stimulator with adjustable current levels and optimized charge balancing technique, demonstrated the capability to meet physiological requirements for beta-cell activation. While integration of AI-based classifiers for advanced FOPP–glucose correlation remains a future step, this study establishes the foundational experimental and technological evidence for a next-generation closed-loop neuromodulator.