Michal Kuchař

Dr. Michal Kuchař

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2009 in Forensic Science International
Verified
Journal Article
Closed access
OROlga Rejtarová
Olga Rejtarová
PHPetr Hejna
Petr Hejna
TSTomáš Soukup
Tomáš Soukup
MKMichal Kuchař
Michal Kuchař

5 August 2024 in International journal of legal medicine
Verified
Journal Article
Open access
PDF file
MKMichal Kuchař
Michal Kuchař
AKAnežka Pilmann Kotěrová
Anežka Pilmann Kotěrová
AMAlexander Morávek
Alexander Morávek
FSFrédéric Santos
Frédéric Santos
KMKatarína Martinková
Katarína Martinková
JBJaroslav Brůžek
Jaroslav Brůžek
Thanks to technical progress and the availability of virtual data, sex estimation methods as part of a biological profile are undergoing an inevitable evolution. Further reductions in subjectivity, but potentially also in measurement errors, can be brought by approaches that automate the extraction of variables. Such automatization also significantly accelerates and facilitates the specialist’s work. The aim of this study is (1) to apply a previously proposed algorithm (Kuchař et al. 2021) to automatically extract 10 variables used for the DSP2 sex estimation method, and (2) to test the robustness of the new automatic approach in a current heterogeneous population. For the first aim, we used a sample of 240 3D scans of pelvic bones from the same individuals, which were measured manually for the DSP database. For the second aim a sample of 108 pelvic bones from the New Mexico Decedent Image Database was used. The results showed high agreement between automatic and manual measurements with rTEM below 5% for all dimensions except two. The accuracy of final sex estimates based on all 10 variables was excellent (error rate 0.3%). However, we observed a higher number of undetermined individuals in the Portuguese sample (25% of males) and the New Mexican sample (36.5% of females). In conclusion, the procedure for automatic dimension extraction was successfully applied both to a different type of data and to a heterogeneous population.

3 August 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PHPetr Henyš
Petr Henyš
MKMichal Kuchař
Michal Kuchař
PHPetr Hájek
Petr Hájek
NHNiels Hammer
Niels Hammer
A new metric for the quantitative and qualitative evaluation of bone stiffness is introduced. It is based on the spectral decomposition of stiffness matrix computed with finite element method. The here proposed metric is defined as an amplitude rescaled eigenvalues of stiffness matrix. The metric contains unique information on the principal stiffness of bone and reflects both bone shape and material properties. The metric was compared with anthropometrical measures and was tested for sex sensitivity on pelvis bone. Further, the smallest stiffness of pelvis was computed under a certain loading condition and analyzed with respect to sex and direction. The metric complements anthropometrical measures and provides a unique information about the smallest bone stiffness independent from the loading configuration and can be easily computed by state-of-the-art subject specified finite element algorithms.

5 June 2026 in International journal of legal medicine
Verified
Journal Article
Open access
MKMichal Kuchař
Michal Kuchař
AMAlexander Morávek
Alexander Morávek
AKAnežka Pilmann Kotěrová
Anežka Pilmann Kotěrová
Eugénia CunhaEugénia Cunha
Eugénia Cunha
TJTomáš Janoušek
Tomáš Janoušek
Background: Biological sex estimation is a cornerstone of the forensic biological profile, and the adult pelvis remains the most informative skeletal region due to pronounced sexual dimorphism. At the same time, three-dimensional documentation of skeletal evidence is rapidly expanding beyond computed tomography and laboratory scanners toward inexpensive, accessible approaches such as photogrammetry—with mobile phone cameras. While the reliability of photogrammetry for osteological documentation has been supported, most established pelvic sexing approaches still assume measurements in absolute units or rely on expert scoring of morphological traits. Methods: We propose and validate a scale-free workflow for sex estimation from unscaled 3D pelvic models. The final approach is based on within-specimen log-ratios of seven collected pelvic measurements rather than on absolute units. Model development used a pooled reference dataset of 2,321 known-sex os coxae from documented dry-bone and CT-derived sources, and external implementation testing targeted unscaled photogrammetric pelvic models acquired under realistic conditions ( n = 103). Results: In the Coimbra photogrammetric subset, the final scale-free model achieved 97.1% binary accuracy, 97.1% balanced accuracy, and an area under curve of 0.997. Under conservative strict thresholds, 90.3% of cases received a definitive classification, all of which were correct, while the remaining 9.7% were retained as indeterminate. Conclusions: Scale-free pelvic sex estimation supports the forensic use of unscaled photogrammetric 3D bone models in situations where reliable external calibration is unavailable. The method does not replace standard calibrated osteometry, but it provides a practical and defensible alternative for low-cost digital documentation, remote analysis, and triage-oriented forensic workflows.

29 April 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
PHPetr Henyš
Petr Henyš
MKMichal Kuchař
Michal Kuchař
PHPetr Hájek
Petr Hájek
NHNiels Hammer
Niels Hammer
A new metric for the quantitative and qualitative evaluation of bone stiffness is introduced. It is based on the spectral decomposition of stiffness matrix computed with finite element method. The here proposed metric is defined as an amplitude rescaled eigenvalues of stiffness matrix. The metric contains unique information on the principal stiffness of bone and reflects both bone shape and material properties. The metric was compared with anthropometrical measures and was tested for sex sensitivity on pelvis bone. Further, the smallest stiffness of pelvis was computed under a certain loading condition and analyzed with respect to sex and direction. The metric complements anthropometrical measures and provides a unique information about the smallest bone stiffness independent from the loading configuration and can be easily computed by state-of-the-art subject specified finite element algorithms.

7 October 2026 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
MKMichal Kuchař
Michal Kuchař
AMAlexander Morávek
Alexander Morávek
NHNiels Hammer
Niels Hammer
PHPetr Henyš
Petr Henyš
Walking, posture and childbirth all depend on the pelvic ring, yet human pelvic dimorphism is usually interpreted from static birth-canal dimensions. We asked whether sex differences in pelvic function are explained by overall size and static pelvimetry or by available mechanical deformation pathways. We analysed 278 anatomically standardized lumbopelvic finite-element models built from clinical computed tomography scans. In each model, modal decomposition separated pelvic deformation into a shared, ranked set of pathways, allowing us to compare pathway stiffness, load recruitment and sensitivity to ligamentous and cartilaginous constraints. Overall pelvic size accounted for much of the baseline stiffness spectrum, confirming a strong size-dependent component. However, size- and age-adjusted sex differences remained: male pelves showed approximately 20% higher eigenvalues than female pelves in modes 2 and 9. Loading probes showed a common backbone in both sexes during habitual support, whereas inlet opening revealed a different response organization, with female pelves distributing deformation across a broader, coordinated set and a higher effective number of participating modes. The principal inlet-opening pathway was most sensitive to the pubic symphysis and anterior sacroiliac ligamentous constraints. Pelvic dimorphism, therefore, lies not only in canal shape, but in the organization of mechanical pathways that balance support with deformation.