Monitoring the fluid pressure within microchannels is crucial for the research of microfluidics and the development of microfluidic devices. Existing pressure sensors embedded within silicon microchannels commonly require drilling holes on the wall surface to install tap lines, which not only alters the microchannel structure but also makes the measurement susceptible to interference from factors such as residual bubbles. In addition, existing methods may also have drawbacks such as poor stability, complex testing systems, assembly difficulties, and low processing reliability. This paper presents a capacitive pressure sensor that can be seamlessly embedded in silicon microchannels for monitoring of dynamic pressure. The sensor has minimal impact on microchannel morphology, making it suitable for pressure measurement in microchannels of various shapes. The manufacturing of the sensor based on MEMS technology is simplified by the application of adhesive bonding. The sensor can monitor microchannel dynamic pressure within 0-120 kPa. The response and recovery times of 68 ms and 79 ms, respectively, highlight the sensor’s excellent dynamic capabilities. Moreover, its stable response over 500 pressure square wave cycles, coupled with the consistency of the response calibration on day 1 and day 63, affirm the sensor’s exceptional stability. Its successful application for the measurement of liquid pressure at various locations within microchannels further attests to its efficacy. These attributes underscore the significant potential of the sensor in the study of the microscale flow.
Pressure measurement in microchannels is crucial for understanding fluid flow behavior and advancing microfluidic device development. However, the micrometer-scale dimensions of microchannels impose significant constraints on the size and sensitivity of embedded pressure sensors, making insufficient sensitivity a primary challenge in pressure measurement. This study proposes a strategy to enhance the sensitivity of capacitive pressure sensors embedded in microchannels by controlling the reference pressure. Firstly, by analyzing the nonlinear output of conventional circular capacitive pressure sensors operating in the normal mode, the sensitivity characteristics of the sensors are determined as the theoretical basis for the proposed strategy. Subsequently, based on this foundation, the core concept of the strategy is developed: adjusting the reference pressure to maintain the pressure difference across the pressure-sensing diaphragm within the range that ensures the required sensitivity for measurement. And the unknown pressure to be measured is determined by subtracting the reference pressure from the measured pressure difference. Finally, a demonstration experiment is conducted to measure gas pressure fluctuations (0–0.10 kPa and 0–0.05 kPa, gauge pressure) and liquid sinusoidal pulsating flows with Reynolds numbers of 55–111, 111–166, and 166–222. The experimental results demonstrate that by controlling the reference pressure, the sensor sensitivity is 7.48 to 9.64 times that achieved under conventional atmospheric reference pressure conditions, effectively validating the feasibility and effectiveness of the proposed strategy.
MEMS capacitive pressure sensors are one of the major classes of pressure sensors. However, in the non-contact operating mode, their sensitivity often varies nonlinearly with the applied pressure, which increases the difficulty and workload of sensitivity evaluation at multiple pressure points during the design stage. In this study, a normalized sensitivity analysis framework for MEMS capacitive pressure sensors is established based on the large-deflection governing equations. Within this framework, the nonlinear relationship between normalized sensitivity and normalized pressure is characterized by five dimensionless parameters. The results show that, when these dimensionless parameters are identical, sensors with different combinations of structural and material parameters collapse onto nearly identical normalized sensitivity-pressure characteristic curves, with an average relative deviation not exceeding 0.05% in the verification cases. In addition, the effects of each dimensionless parameter on the nonlinear behavior of the characteristic curves are further analyzed. The proposed framework provides a unified and systematic analytical basis for sensitivity comparison, performance evaluation, and structural optimization of MEMS capacitive pressure sensors.