High-precision, low-temperature-sensitive microelectromechanical system (MEMS) capacitive accelerometers are widely used in aerospace, automotive, and navigation systems. An analytical study of the temperature drift of bias (TDB) and temperature drift of scale factor (TDSF) for an asymmetric comb capacitive accelerometer is presented in this paper. A five-layer model is established for the equivalent expansion ratio in the TDB and TDSF formulas, and the results calculated by the weighted average of thickness and elasticity modulus method are closest to the results of the numerical simulation. The analytical formulas of TDB and TDSF for an asymmetric structure are obtained. For an asymmetric structure, TDB is only related to thermal deformation and fabrication error. Additionally, half of the fixed electrode distance is not included in the expressions of and for asymmetric structures, thus resulting in the TDSF of the asymmetric structure being smaller compared to a symmetric structure with the same structural parameters. The TDSF of the symmetric structure is [−200.2 ppm/°C, −261.6 ppm/°C], while the results of the asymmetric structure are [−11.004 ppm/°C, −72.404 ppm/°C] under the same set of parameters. The parameters of the optimal asymmetric structure are obtained for fabrication guidance using numerical methods. In the experiment, the TDSF and TDB of the packaged structure and the non-packaged structure are compared, and a significant effect of the package on the signal output is found. The TDB is reduced from 3000 to 60 μg/°C, while the TDSF is reduced from 3000 to 140 ppm/°C.
Silicon carbide (SiC) is currently the preferred material for micro-electromechanical system (MEMS) sensors used in extreme environments and it has been applied in many high-temperature piezoresistive sensors. However, there has been a lack of accumulated data and references for research on the characteristics of the 4H-SiC substrate and thin-film resistors used in high-temperature environments. Consequently, the effect of temperature on the sensor in high-temperature environments cannot be evaluated in advance at the design stage. In this study, the mechanical characteristics of a 4H-SiC substrate and the thin-film resistor resistivity were examined based on the temperature error model of a typical MEMS piezoresistive sensor and the temperature function models were established, which could be used to analyze the temperature effect of the sensors under high temperature conditions. All the test data were integrated into a typical physical chip including a 4H-SiC substrate and thin-film resistors. The simulation results of the device exhibited a high consistency with the test results, the largest average error being only 4.53%, verifying the correctness and validity of the test data. This study proposed the data models for the temperature characteristics of 4H-SiC materials, providing powerful support for the design and development of high-temperature MEMS sensors.
In recent years, the analysis and improvement of temperature characteristics of Si-based capacitive accelerometers has received considerable research attention in the field of Microelectromechanical system (MEMS) sensors. Generally, the influence of temperature on the accelerometers can be mitigated by optimizing the structural design and compensating the output signal. Herein, the output characteristics of an accelerometer designed with asymmetrically arranged combs were analyzed under various temperatures. The purpose of this paper is to improve the temperature drift of scale factor (TDSF) of MEMS capacitive accelerometer, using the asymmetric layout structure to improve the TDSF fundamentally, and the least square method to achieve temperature compensation efficiently. The variations in the TDSF were compared for the symmetric and asymmetric structures. In addition, we modeled the accelerometer with an asymmetric structure for simulations to analyze the errors resulting from the electrostatic torsion phenomenon induced by the asymmetric structure. Moreover, a temperature compensation model was developed for the scale factor of the accelerometer, which was validated and verified with the data obtained from simulations and experiment. Furthermore, an accelerometer based on silicon on insulator was fabricated and tested to verify the simulation results and the compensation effects. According to the results, the scale factor of the studied accelerometer was 171.83 mV g−1 and the average value of the TDSF was 83.56 ppm °C−1 Overall, the experimental results were almost consistent with the simulation results. Under the asymmetric layout, the scale-factor stability improvement of the accelerometer could reach up to 86.96%, and the error caused by electrostatic torsion was ∼2.93%, which is relatively negligible. After compensation, the range and standard deviation of the scale factor of the accelerometer with respect to temperature were reduced by 94.46% and 95.69%, respectively, and the average value of TDSF was reduced by 95.90%, which verified the effectiveness of the compensation model.
Monitoring the fluid pressure within microchannels is crucial for the research of microfluidics and the development of microfluidic devices. Existing pressure sensors embedded within silicon microchannels commonly require drilling holes on the wall surface to install tap lines, which not only alters the microchannel structure but also makes the measurement susceptible to interference from factors such as residual bubbles. In addition, existing methods may also have drawbacks such as poor stability, complex testing systems, assembly difficulties, and low processing reliability. This paper presents a capacitive pressure sensor that can be seamlessly embedded in silicon microchannels for monitoring of dynamic pressure. The sensor has minimal impact on microchannel morphology, making it suitable for pressure measurement in microchannels of various shapes. The manufacturing of the sensor based on MEMS technology is simplified by the application of adhesive bonding. The sensor can monitor microchannel dynamic pressure within 0-120 kPa. The response and recovery times of 68 ms and 79 ms, respectively, highlight the sensor’s excellent dynamic capabilities. Moreover, its stable response over 500 pressure square wave cycles, coupled with the consistency of the response calibration on day 1 and day 63, affirm the sensor’s exceptional stability. Its successful application for the measurement of liquid pressure at various locations within microchannels further attests to its efficacy. These attributes underscore the significant potential of the sensor in the study of the microscale flow.
In this study, a 3D coil embedded in a silicon substrate including densely distributed through-silicon vias (TSVs) was fabricated via a rapid metal powder sintering process. The filling and sintering methods for microdevices were evaluated, and the effects of powder types were compared. The parameters influencing the properties and processing speed were analyzed. The results showed that the pre-alloyed powder exhibited the best uniformity and stability when the experiment used two or more types of powders to avoid the segregation effect. The smaller the particle diameter, the better the inductive performance will be. The entire structure can be sintered near the melting point of the alloy, and increasing the temperature increases strength, while resulting in low resistivity. Finally, an 800-µm-high coil was fabricated. This process does not need surface metallization and seed layer formation. The forming process involves only sintering instead of slowly growing copper with a tiny current. Therefore, this process has advantages, such as a process time of 7 h, corresponding to an 84% reduction compared to current electroplating processes (45 h), and a 543% efficiency improvement. Thus, this process is more efficient, controllable, stable, and suitable for mass production of devices with flexible dimensions.