Bogu Huang

Mr. Bogu Huang


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2026 in Mathematics
Verified
Journal Article
Open access
PDF file
BHBogu Huang
Bogu Huang
YWYibo Wang
Yibo Wang
YGYuhan Guo
Yuhan Guo
WYWentao Yang
Wentao Yang
YWYuxuan Wu
Yuxuan Wu
YHYanxin Hu
Yanxin Hu
Although the weak-grid stability of grid-following inverters has been widely studied, traditional SCR-based assessment mainly describes grid strength and does not directly quantify the minimum SCR required for stable operation under a specified active-power command. This paper uses a critical-SCR-oriented operating-boundary evaluation to compare the control-dependent dynamic stability requirement with the physical steady-state feasibility limit. It proposes a channel-specific impedance-reshaping extension that retains the PLL-related q-q and d-q compensation paths and adds a voltage-loop-related q-d compensation path. The added path reduces the control-induced dynamic critical SCR, thereby allowing stable operation at lower SCR than with the original control structure. Firstly, the steady-state critical SCR is derived from the steady-state power-transfer relation under a specified active-power command to define the physical feasibility lower bound, and the dynamic critical SCR is identified using a scanning procedure based on the generalized Nyquist criterion. The resulting control-induced SCR gap quantifies the additional grid-strength requirement introduced by the control dynamics. Secondly, a simplified d-q admittance representation is used to relate established PLL-related and voltage-loop-related coupling effects to the corresponding compensation paths. Thirdly, the proposed channel-specific impedance-reshaping design is used to mitigate these effects while retaining the selected voltage-loop bandwidth, and an anti-drift correction is further introduced to improve implementation robustness. Frequency-domain analysis and time-domain simulations validate the dynamic critical-SCR evaluation, while hardware-in-the-loop experiments demonstrate the real-time operation of the proposed controller. The results show that it moves the dynamic critical-SCR boundary close to the steady-state physical boundary and improves the weak-grid stability margin. The hardware-in-the-loop results further confirm bounded operation under SCR and frequency steps.

17 September 2026 in Processes
Verified
Journal Article
Open access
PDF file
ZZZhijie Zeng
Zhijie Zeng
XLXiaoqing Lin
Xiaoqing Lin
DCDawei Chen
Dawei Chen
BHBogu Huang
Bogu Huang
HZHaiqiao Zhao
Haiqiao Zhao
The stable operation of doubly fed induction generator (DFIG) systems under weak-grid and off-nominal-frequency conditions is important for reliable wind-power integration. However, the phase-locked loop (PLL) dynamics can degrade DFIG impedance and damping, while conventional single-PLL reshaping may suffer from compensation drift under grid-frequency deviations and often relies on a high-pass filter. Therefore, this paper proposes an integrated Double-PLL-Based impedance-reshaping strategy for DFIG systems. Firstly, a complete DFIG admittance model incorporating the rotor-side converter, grid-side converter, DC link, and PLL dynamics is established to identify the critical coupling channel responsible for the adverse impedance characteristics. Secondly, a supplementary rotor-current compensation path is constructed to directly reshape the adverse impedance characteristics and improve system damping. Thirdly, the relative phase angle between the main and auxiliary PLLs is used to generate a frequency-adaptive compensation signal, thereby avoiding continuous compensation drift under persistent frequency deviations and reducing reliance on a dedicated high-pass filter. In this complete strategy, the compensation path directly performs impedance reshaping, while the Double-PLL-Based implementation provides frequency adaptation. Finally, generalized Nyquist analysis and MATLAB/Simulink simulations demonstrate improved impedance matching and oscillation suppression under the considered weak-grid and continuous-frequency-deviation conditions, while hardware-in-the-loop (HIL) experiments corroborate the robustness under PLL-parameter variations.

10 August 2026 in Mathematics
Verified
Journal Article
Open access
PDF file
WYWentao Yang
Wentao Yang
YWYibo Wang
Yibo Wang
BHBogu Huang
Bogu Huang
YGYuhan Guo
Yuhan Guo
YWYuxuan Wu
Yuxuan Wu
This paper develops a measurable unified electric–thermal energy indicator for converter-dominated microgrids, containing virtual synchronous generator (VSG) and virtual asynchronous machine (VAM) dynamics. The principal contribution comprises the scalar energy indicator HΣ and its normalized margin ηstab; together, they combine active-power–frequency, reactive-power–voltage, thermal-flow, current-boundary, and electric–thermal coupling information obtained from point-of-common-coupling measurements and thermal states. A bounded event-triggered thermal–electric action is used only as a secondary demonstration of how the indicator can support current-constrained coordination; it is not proposed as a replacement for the inner VSG controller. Local positive-definiteness, dissipation, invariant-sublevel-set, and two-time-scale conditions are derived in an explicitly defined operating domain. The framework was evaluated in a three-phase Simulink/Simscape model using a 26-run matrix of disturbance and parameter cases, together with three severe-case baselines and four reduced-order channel-isolation cases. For voltage-sag depths of 5–20%, the event increase in HΣ/Hcrit rose from 0.137 to 0.385. In the severe 20% combined case, bounded coordination increased the minimum margin from 0.048 to 0.138, with 0.0897 kWh of heat-load reduction; however, its trajectory was identical to that of the matched current-threshold trigger, so no controller-performance superiority is claimed. Omitting Hqv, Hth, Hlim and Hcpl eliminated 100.0%, 99.7%, 90.8% and 87.3%, respectively, of the corresponding event-window sensitivity. Under deep-current saturation, the limiter gain fell to 0.466 and ηstab reached zero, numerically identifying a boundary beyond which the local stability guarantee must not be extrapolated.