Yuhan Guo

Mr. Yuhan Guo


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2026 in Mathematics
Verified
Journal Article
Open access
PDF file
BHBogu Huang
Bogu Huang
YWYibo Wang
Yibo Wang
YGYuhan Guo
Yuhan Guo
WYWentao Yang
Wentao Yang
YWYuxuan Wu
Yuxuan Wu
YHYanxin Hu
Yanxin Hu
Although the weak-grid stability of grid-following inverters has been widely studied, traditional SCR-based assessment mainly describes grid strength and does not directly quantify the minimum SCR required for stable operation under a specified active-power command. This paper uses a critical-SCR-oriented operating-boundary evaluation to compare the control-dependent dynamic stability requirement with the physical steady-state feasibility limit. It proposes a channel-specific impedance-reshaping extension that retains the PLL-related q-q and d-q compensation paths and adds a voltage-loop-related q-d compensation path. The added path reduces the control-induced dynamic critical SCR, thereby allowing stable operation at lower SCR than with the original control structure. Firstly, the steady-state critical SCR is derived from the steady-state power-transfer relation under a specified active-power command to define the physical feasibility lower bound, and the dynamic critical SCR is identified using a scanning procedure based on the generalized Nyquist criterion. The resulting control-induced SCR gap quantifies the additional grid-strength requirement introduced by the control dynamics. Secondly, a simplified d-q admittance representation is used to relate established PLL-related and voltage-loop-related coupling effects to the corresponding compensation paths. Thirdly, the proposed channel-specific impedance-reshaping design is used to mitigate these effects while retaining the selected voltage-loop bandwidth, and an anti-drift correction is further introduced to improve implementation robustness. Frequency-domain analysis and time-domain simulations validate the dynamic critical-SCR evaluation, while hardware-in-the-loop experiments demonstrate the real-time operation of the proposed controller. The results show that it moves the dynamic critical-SCR boundary close to the steady-state physical boundary and improves the weak-grid stability margin. The hardware-in-the-loop results further confirm bounded operation under SCR and frequency steps.

6 August 2026 in Mathematics
Verified
Journal Article
Open access
PDF file
WYWentao Yang
Wentao Yang
YWYibo Wang
Yibo Wang
YGYuhan Guo
Yuhan Guo
RZRunze Zhang
Runze Zhang
Converter-dominated power systems increasingly require flexible resources that can support frequency while preserving a physically interpretable energy trajectory. Thermal-energy-storage (TES)-based virtual energy storage systems (VESSs) can shift electrical demand within thermal-energy and comfort constraints, and have therefore attracted extensive interest. However, existing studies commonly coordinate requested or normalized power without fully connecting it to actuator execution and the electrical-to-thermal energy path. Command-level sharing cannot be directly equated with executed physical power, and controller storage cannot be combined with joule-valued hardware energy without dimensional separation. Therefore, this paper proposes a physically coupled and energy-traceable virtual asynchronous machine (VAM) control method for TES-based VESSs. First, a loss-resolved averaged model establishes the point-of-common-coupling (PCC)–converter–DC-link–actuator–TES physical chain and separates the hardware Hamiltonian from the dimensionless control Lyapunov function. Second, a neighbor-coupled marginal controller is embedded in a command–projection–execution chain so that frequency regulation and weighted sharing are evaluated using the executed service. Third, a constraint-handling mechanism combines directional headroom gating, actuator saturation and ramp limits, thermal comfort bounds, and request-inactive state reset to maintain executable trajectories under the declared constraints. Simulations under a sustained 120kW disturbance show that primary-only control retains a −0.08883Hz steady-state offset, whereas the proposed nominal case restores frequency. In the constrained case, the 30 s terminal trend remains above the prescribed limit, while both terminal windows of the 60 s run satisfy the restoration criterion; the final-window mean error and dimensionless eligible-unit sharing spread are −6.317×10−5Hz and 6.564×10−5, respectively. The model-internal electrical–thermal balance achieves a dimensionless relative RMS residual of 6.2361×10−8. Because the PCC voltage/current pair is reconstructed from the same power source, this residual quantifies model-internal consistency rather than independent measured closure. These results demonstrate constrained frequency restoration, executed-power coordination, and energy traceability within the averaged-model scope.

10 August 2026 in Mathematics
Verified
Journal Article
Open access
PDF file
WYWentao Yang
Wentao Yang
YWYibo Wang
Yibo Wang
BHBogu Huang
Bogu Huang
YGYuhan Guo
Yuhan Guo
YWYuxuan Wu
Yuxuan Wu
This paper develops a measurable unified electric–thermal energy indicator for converter-dominated microgrids, containing virtual synchronous generator (VSG) and virtual asynchronous machine (VAM) dynamics. The principal contribution comprises the scalar energy indicator HΣ and its normalized margin ηstab; together, they combine active-power–frequency, reactive-power–voltage, thermal-flow, current-boundary, and electric–thermal coupling information obtained from point-of-common-coupling measurements and thermal states. A bounded event-triggered thermal–electric action is used only as a secondary demonstration of how the indicator can support current-constrained coordination; it is not proposed as a replacement for the inner VSG controller. Local positive-definiteness, dissipation, invariant-sublevel-set, and two-time-scale conditions are derived in an explicitly defined operating domain. The framework was evaluated in a three-phase Simulink/Simscape model using a 26-run matrix of disturbance and parameter cases, together with three severe-case baselines and four reduced-order channel-isolation cases. For voltage-sag depths of 5–20%, the event increase in HΣ/Hcrit rose from 0.137 to 0.385. In the severe 20% combined case, bounded coordination increased the minimum margin from 0.048 to 0.138, with 0.0897 kWh of heat-load reduction; however, its trajectory was identical to that of the matched current-threshold trigger, so no controller-performance superiority is claimed. Omitting Hqv, Hth, Hlim and Hcpl eliminated 100.0%, 99.7%, 90.8% and 87.3%, respectively, of the corresponding event-window sensitivity. Under deep-current saturation, the limiter gain fell to 0.466 and ηstab reached zero, numerically identifying a boundary beyond which the local stability guarantee must not be extrapolated.