Yibo Wang

Dr. Yibo Wang

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
Rui WangRui Wang
Rui Wang
YWYibo Wang
Yibo Wang
PZPinjia Zhang
Pinjia Zhang
Qiuye SunQiuye Sun
Qiuye Sun
Yonghao GuiYonghao Gui
Yonghao Gui
Peng WangPeng Wang
Peng Wang
As the number of inverter-interfaced distributed generators (IIDGs) increases, the decrease in the inertia of the microgrid affects the stability of microgrid voltage and current. The virtual synchronous generator (VSG) control method simulates the output characteristics of the synchronous machine to improve the inertia and damping of the microgrid. However, low-frequency oscillations can occur in systems with multi-VSGs connected in parallel, primarily when operating in island mode. Therefore, this article develops the small-signal state-space model for multi-inverters based on VSG and analyses the robust stability region (RSR) of the control parameters. Firstly, an extensible small-signal state-space model is established and simplified in the dq axis, which is a necessary preprocessing for the subsequent stability analysis. Secondly, the guardian map method based on bialternate product operation is constructed, and the RSR is established through translation mapping and rotation mapping. Therefore, the solution of RSR is transformed into the problem of identifying the Hurwitz matrix. Finally, the simulations and experiments verify that the calculated region can ensure stable operation during startup and meet the requirement to suppress low-frequency oscillations. The method of solving RSR proposed in this paper provides a basis for selecting controller parameters in practical engineering.

30 March 2024 in Mathematics
Verified
Journal Article
Open access
PDF file
YWYibo Wang
Yibo Wang
FCFutao Chen
Futao Chen
WJWei Jia
Wei Jia
Rui WangRui Wang
Rui Wang
Large-scale wind farms incorporating doubly-fed induction generators (DFIGs) are considered a promising direction for modern energy supply systems due to their role in reducing dependence on fossil energy sources. However, the dynamic interactions between DFIGs and AC grids sometimes lead to sub-synchronous oscillation (SSO) that threatens the safe and stable operation of wind power systems. Therefore, it is essential to develop a mathematical model and design an algorithm to quantitatively design the control parameters. Such algorithms are helpful in preventing or mitigating system stability problems coming from wind power connected to the grid and reducing damage to power equipment. The traditional state-space model is mainly established to determine the stable operating point and analyze the influence of parameters on the system operating mode. However, this method does not provide the selection area for the system parameters. To address this shortcoming, this paper introduces a modular state-space model for DFIGs containing series compensation lines and proposes an algorithm for calculating the parameter selection area based on the Guardian map method. First, a detailed modular state-space model based on the virtual synchronous generator (VSG) control is established. The modular model helps to reflect the relationship between state variables and focuses on describing the operating state of DFIGs in wind farms. Second, this paper focuses on the influence of VSG control parameters and compensation capacitance on SSO. It aims to clarify the role of the series compensation level and control parameters on SSO based on VSG control. Then, an algorithm for the parameter selection area based on the Guardian map is proposed and the area of the VSG-controlled DFIG is obtained. Finally, the accuracy and validity of the algorithm are verified by time domain simulation in MATLAB/Simulink and HIL experiment.

29 July 2025 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
YWYibo Wang
Yibo Wang
Rui WangRui Wang
Rui Wang
Qiuye SunQiuye Sun
Qiuye Sun
MLMing-Jia Li
Ming-Jia Li
pinjia zhangpinjia zhang
pinjia zhang
Peng WangPeng Wang
Peng Wang
The solar thermoelectric module (STEM) serves as a versatile interface for the conversion between thermal and electrical energy. It typically operates in two modes: thermoelectric heater (TEH) and thermoelectric generator (TEG). However, traditional control methods, such as the virtual synchronous generator (VSG), primarily focus on power balance in TEG mode. The potential of STEM in TEH mode for grid regulation is often overlooked. Therefore, this paper proposes a novel control strategy for STEM to achieve power balance during both power generation and load operation. Firstly, a thermodynamic model of the STEM considering the Thomson effect and external heat exchange is developed. Secondly, this paper develops a unified equivalent circuit based on the thermodynamic models and rated operating parameters of TEG and TEH. The equivalent circuit supports the bidirectional operation of the STEM. Moreover, a source–load seamless-switching control strategy for STEM is proposed, using VSG in TEG mode and the virtual asynchronous machine (VAM) in TEH mode. This enables STEM to achieve real-time power balance under all working modes. Finally, six operating scenarios are set for the proposed strategy, and the performance and effectiveness are verified through simulation and hardware-in-the-loop (HIL) experiments.

28 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
CGCailian Gu
Cailian Gu
YWYibo Wang
Yibo Wang
WWWeisheng Wang
Weisheng Wang
YGYang Gao
Yang Gao
Aiming at the problems of power flow fluctuation and voltage exceeding standard caused by high permeability distributed power supply access, this paper proposes a load state perception early warning method for distribution networks. Firstly, the random behavior characteristics and voltage early warning mechanisms of power supply and load in distribution networks are analyzed, the dynamic model of distribution networks based on complex network theory is established, and the risk index of voltage exceeding limits under the conditions of high permeability distributed power supply access is put forward. Secondly, the random power flow of distribution networks based on the Monte Carlo method is studied by sampling and analyzing the dynamic model of distribution networks. Then, the risk calculation and safety assessment of voltage exceeding limits are carried out on the currently extracted model, and the risk control strategy of distribution network operation is put forward. Finally, an improved IEEE30-node distribution network topology is proposed. Through simulation analysis, it is proven that the load situation awareness early warning method of distribution networks can effectively predict, improve the security of distribution networks, and provide timely early warning information for maintenance personnel.

12 August 2026 in Mathematics
Verified
Journal Article
Open access
PDF file
BHBogu Huang
Bogu Huang
YWYibo Wang
Yibo Wang
YGYuhan Guo
Yuhan Guo
WYWentao Yang
Wentao Yang
YWYuxuan Wu
Yuxuan Wu
YHYanxin Hu
Yanxin Hu
Although the weak-grid stability of grid-following inverters has been widely studied, traditional SCR-based assessment mainly describes grid strength and does not directly quantify the minimum SCR required for stable operation under a specified active-power command. This paper uses a critical-SCR-oriented operating-boundary evaluation to compare the control-dependent dynamic stability requirement with the physical steady-state feasibility limit. It proposes a channel-specific impedance-reshaping extension that retains the PLL-related q-q and d-q compensation paths and adds a voltage-loop-related q-d compensation path. The added path reduces the control-induced dynamic critical SCR, thereby allowing stable operation at lower SCR than with the original control structure. Firstly, the steady-state critical SCR is derived from the steady-state power-transfer relation under a specified active-power command to define the physical feasibility lower bound, and the dynamic critical SCR is identified using a scanning procedure based on the generalized Nyquist criterion. The resulting control-induced SCR gap quantifies the additional grid-strength requirement introduced by the control dynamics. Secondly, a simplified d-q admittance representation is used to relate established PLL-related and voltage-loop-related coupling effects to the corresponding compensation paths. Thirdly, the proposed channel-specific impedance-reshaping design is used to mitigate these effects while retaining the selected voltage-loop bandwidth, and an anti-drift correction is further introduced to improve implementation robustness. Frequency-domain analysis and time-domain simulations validate the dynamic critical-SCR evaluation, while hardware-in-the-loop experiments demonstrate the real-time operation of the proposed controller. The results show that it moves the dynamic critical-SCR boundary close to the steady-state physical boundary and improves the weak-grid stability margin. The hardware-in-the-loop results further confirm bounded operation under SCR and frequency steps.

6 August 2026 in Mathematics
Verified
Journal Article
Open access
PDF file
WYWentao Yang
Wentao Yang
YWYibo Wang
Yibo Wang
YGYuhan Guo
Yuhan Guo
RZRunze Zhang
Runze Zhang
Converter-dominated power systems increasingly require flexible resources that can support frequency while preserving a physically interpretable energy trajectory. Thermal-energy-storage (TES)-based virtual energy storage systems (VESSs) can shift electrical demand within thermal-energy and comfort constraints, and have therefore attracted extensive interest. However, existing studies commonly coordinate requested or normalized power without fully connecting it to actuator execution and the electrical-to-thermal energy path. Command-level sharing cannot be directly equated with executed physical power, and controller storage cannot be combined with joule-valued hardware energy without dimensional separation. Therefore, this paper proposes a physically coupled and energy-traceable virtual asynchronous machine (VAM) control method for TES-based VESSs. First, a loss-resolved averaged model establishes the point-of-common-coupling (PCC)–converter–DC-link–actuator–TES physical chain and separates the hardware Hamiltonian from the dimensionless control Lyapunov function. Second, a neighbor-coupled marginal controller is embedded in a command–projection–execution chain so that frequency regulation and weighted sharing are evaluated using the executed service. Third, a constraint-handling mechanism combines directional headroom gating, actuator saturation and ramp limits, thermal comfort bounds, and request-inactive state reset to maintain executable trajectories under the declared constraints. Simulations under a sustained 120kW disturbance show that primary-only control retains a −0.08883Hz steady-state offset, whereas the proposed nominal case restores frequency. In the constrained case, the 30 s terminal trend remains above the prescribed limit, while both terminal windows of the 60 s run satisfy the restoration criterion; the final-window mean error and dimensionless eligible-unit sharing spread are −6.317×10−5Hz and 6.564×10−5, respectively. The model-internal electrical–thermal balance achieves a dimensionless relative RMS residual of 6.2361×10−8. Because the PCC voltage/current pair is reconstructed from the same power source, this residual quantifies model-internal consistency rather than independent measured closure. These results demonstrate constrained frequency restoration, executed-power coordination, and energy traceability within the averaged-model scope.