Crude oil is an indispensable energy feedstock for daily activities, although some amounts of metallic porphyrins components with undesired characteristics have been identified. These constituents are assumed to originate from the geochemical process of chlorophyll and heme derivatives. In addition, their chemical structures have been thoroughly characterized using spectroscopy techniques, while several analytical methods were adopted in the detection and concentration quantification in the crude oils. The metallic porphyrins have several demerits, including the deactivation of used catalysts, contamination of the treated petrochemical products, and corrosion of the industrial equipment. Also, the removal process is considered challenging due to the strong interaction with the asphaltene fraction of crude oil. This review article, therefore, provides brief information on the origin, physicochemical properties, and possible removal technology of metallic porphyrins from crude oil samples. Besides, a better understanding of chemistry contributes a useful insight towards the development and establishment of better futuristic processing technology.
Pool boiling surface modification by pin fin array has demonstrated a practical but effective cooling enhancement. Whilst the main challenge is to determine the best configuration of the pin fin dimensions and positioning, it is known that the result varies among the working conditions. To obtain a more general formulation, it is utterly vital to obtain a deep understanding of the pool boiling mechanism during the phase-change process. This study aimed to analyze the role of pin fin array configuration on the pool boiling phenomenon by generating visualization and non-dimensional analysis. The results illustrated three different regimes occurring during the boiling process: natural convection, isolated bubble, and merged bubble. For all regimes, the average heat transfer performance was enhanced as the fin gap rose to 17% and 63% for circular and rectangular pin fins, respectively. Furthermore, Grashof (Gr) and Bond (Bo) numbers were calculated to quantitatively describe the effect on the bubble dynamics. From these approaches, it was found that the insulated bubble regime provides a better means of cooling by around 60% due to the better bubble dynamics.
This paper presents an experimental study on thermal behaviors of phase change material (PCM) during melting process in annulus cylinder. The inner cylinder was functioned as PCM storage, the outer cylinder was designed as shell, and both were made of acrylic. The PCM Storage was heated on its surface by circulating hot water as heat transfer fluid (HTF) in the shell. The variations of HTF temperature are 60, 65, 70°C and its mass flow rate is maintained at 4 liter per minutes. Thermal analysis of the melting process over time is given to provide more specific information of temperature contour change during the process. Solid–liquid melting process is shown by sequential photographs taken by the digital camera during the process in axial and radial direction. The results indicate that at the beginning of melting process, the heat transfer is dominated by conduction between inner wall of PCM storage and solid PCM. When the PCM has melt, convection holds important role in the heat transfer due to density gradient of the liquid PCM. Increasing of 5°C temperature is able to reduce about 34% of the total melting time.
JSJalan Pacar No. 8 Badan Perencanaan Pembangunan Kota Surabaya
Jalan Pacar No. 8 Badan Perencanaan Pembangunan Kota Surabaya
+3
In this research, cooling system optimization using thermal energy storage (TES) in shopping center buildings was investigated. Cooling systems in commercial buildings account for up to 50% of their total energy consumption. This incurs high electricity costs related to the tariffs determined by the Indonesian government with the price during peak hours up to twice higher than during off-peak hours. Considering the problem, shifting the use of electrical load away from peak hours is desirable. This may be achieved by using a cooling system with TES. In a TES system, a chiller produces cold water to provide the required cooling load and saves it to a storage tank. Heat loss in the storage tank has to be considered because greater heat loss requires additional chiller capacity and investment costs. Optimization of the cooling system was done by minimizing the combination of chiller capacity, cooling load and heat loss using simplex linear programming. The results showed that up to 20% electricity cost savings can be achieved for a standalone shopping center building.
Performance of stratified thermal energy storage tank is strongly influenced by separation layer between the hot and cool water stored in the tank. This separation layer is evaluated from water temperature inside of the tank. However, difficulty in converting the temperature distribution into performance parameters has been found. In this research, determination of performance parameters from the temperature distribution is investigated. The temperature distributions are obtained from experimental data simulating charging cycle in hot stratified thermal energy storage tank with varies charging flow rates. Determination of the performance parameters are carried out based on temperature distribution utilizing Sigmoid Dose Response formulation. The results show that significant parameter namely thermocline thickness, cumulative cooling capacity and half-cycle Figure of Merit are precisely determined during the charging cycle. Moreover, the parameters growth is also capable to be evaluated precisely in the charging step. The research results proved the ability of SDR formulation for determining the performance parameter in stratified thermal energy storage tank. It his highlighted that the SDR formulation offers advantage of determination performance parameter accurately.