Bo Li

Dr. Bo Li

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
BLBo Li
Bo Li
YHYiwei Hao
Yiwei Hao
HZHanlin Zhu
Hanlin Zhu
YDYu Dai
Yu Dai
XKXinxin Kong
Xinxin Kong
WZWenxi Zhang
Wenxi Zhang
We propose a compact heterodyne point-diffraction interferometer (PDI) based on dual-cascaded acousto-optic modulators (AOM), that featuring adjustable contrast and high repeatability. The novel dual-cascaded AOM module integrates the functions of frequency shifting, beam splitting, and contrast modulation. The incident beam is split into two parallel beam pairs with a frequency difference. Beams are evenly arranged around the optical axis of a focusing lens so they enter the diffraction pinhole together. By modulating the AOMs' input RF power, the interference contrast can be flexibly adjusted. Compared with traditional configurations, this system is not only more compact but also capable of measuring larger-aperture and higher-mass components. Simulation and experimental results verify the feasibility of the proposed PDI, achieving a measurement repeatability of less than 0.6 nm (RMS).

20 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BLBo Li
Bo Li
YHYiwei Hao
Yiwei Hao
HZHanlin Zhu
Hanlin Zhu
XKXinxin Kong
Xinxin Kong
ZWZhou Wu
Zhou Wu
WZWenXi Zhang
WenXi Zhang
Conventional pinhole point-diffraction interferometers (PPDIs) owe their popularity to a simple configuration, but that same configuration limits both the usable measurement aperture and the load the phase shifter can carry. Here, we propose a heterodyne phase-shifting point-diffraction interferometer (HPDI) based on dual-cascaded acousto-optic modulators (AOMs), which removes both limitations while keeping the configuration compact. The dual-cascaded AOM module integrates the functions of frequency shifting, beam splitting, and contrast modulation. By modulating its input RF power, the interference contrast can be flexibly adjusted. Simulation and experimental results verify the feasibility of the proposed HPDI, which achieves a measurement repeatability of 0.045 nm (RMS, with piston, tilt, and defocus removed) and agrees with an absolute shift-rotation calibration to within 3.3 nm (RMS).

14 October 2026 in Optics Letters
Verified
Journal Article
Closed access
PDF file
BLBo Li
Bo Li
YHYiwei Hao
Yiwei Hao
WZWenXi Zhang
WenXi Zhang
XKXinxin Kong
Xinxin Kong
ZWZhou Wu
Zhou Wu
We introduce what we believe to be a novel crosstalk-removal algorithm to eliminate phase errors in dual-beam point-diffraction interferometry. The method establishes a generalized four-beam interference error model. By using Fourier-carrier least-squares fitting and an iterative optimization based on micro-perturbation, crosstalk-induced error can be effectively eliminated. To the best of our knowledge, no relevant study on mitigating such four-beam interference errors has been previously reported.