Carlo Molardi

Dr. Carlo Molardi

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
KDKanat Dukenbayev
Kanat Dukenbayev
IKIlya Korolkov
Ilya Korolkov
Daria TishkevichDaria Tishkevich
Daria Tishkevich
Artem KozlovskiyArtem Kozlovskiy
Artem Kozlovskiy
STSergei Trukhanov
Sergei Trukhanov
CMCarlo Molardi
Carlo Molardi
Magnetic Fe3O4 nanoparticles (NPs) and their surface modification with therapeutic substances are of great interest, especially drug delivery for cancer therapy, including boron-neutron capture therapy (BNCT). In this paper, we present the results of boron-rich compound (carborane borate) attachment to previously aminated by (3-aminopropyl)-trimethoxysilane (APTMS) iron oxide NPs. Fourier transform infrared spectroscopy with Attenuated total reflectance accessory (ATR-FTIR) and energy-dispersive X-ray analysis confirmed the change of the element content of NPs after modification and formation of new bonds between Fe3O4 NPs and the attached molecules. Transmission (TEM) and scanning electron microscopy (SEM) showed Fe3O4 NPs’ average size of 18.9 nm. Phase parameters were studied by powder X-ray diffraction (XRD), and the magnetic behavior of Fe3O4 NPs was elucidated by Mössbauer spectroscopy. The colloidal and chemical stability of NPs was studied using simulated body fluid (phosphate buffer—PBS). Modified NPs have shown excellent stability in PBS (pH = 7.4), characterized by XRD, Mössbauer spectroscopy, and dynamic light scattering (DLS). Biocompatibility was evaluated in-vitro using cultured mouse embryonic fibroblasts (MEFs). The results show us an increasing of IC50 from 0.110 mg/mL for Fe3O4 NPs to 0.405 mg/mL for Fe3O4-Carborane NPs. The obtained data confirm the biocompatibility and stability of synthesized NPs and the potential to use them in BNCT.

1 July 2018 in Optical Fiber Technology
Verified
Journal Article
Closed access
DTDaniele Tosi
Daniele Tosi
ESEmiliano Schena
Emiliano Schena
CMCarlo Molardi
Carlo Molardi
SKSanzhar Korganbayev
Sanzhar Korganbayev

22 July 2019 in Optics Express
Verified
Journal Article
Open access
ABAidana Beisenova
Aidana Beisenova
AIAizhan Issatayeva
Aizhan Issatayeva
IIIulian Iordachita
Iulian Iordachita
Wilfried BlancWilfried Blanc
Wilfried Blanc
CMCarlo Molardi
Carlo Molardi
DTDaniele Tosi
Daniele Tosi
A novel approach for fiber optics 3D shape sensing, applicable to mini-invasive bio-medical devices, is presented. The approach exploits the optical backscatter reflectometry (OBR) and an innovative setup that permits the simultaneous spatial multiplexing of an optical fibers parallel. The result is achieved by means of a custom-made enhanced backscattering fiber whose core is doped with MgO-based nanoparticles (NP). This special NP-doped fiber presents a backscattering-level more than 40 dB higher with respect to a standard SMF-28. The fibers parallel is built to avoid overlap between NP-doped fibers belonging to different branches of the parallel, so that the OBR can distinguish the more intense backscattered signal coming from the NP-doped fiber. The system is tested by fixing, with epoxy glue, 4 NP-doped fibers along the length of an epidural needle. Each couple of opposite fibers senses the strain on a perpendicular direction. The needle is inserted in a custom-made phantom that simulates the spine anatomy. The 3D shape sensing is obtained by converting the measured strain in bending and shape deformation.

6 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ABAliya Bekmurzayeva
Aliya Bekmurzayeva
KDKanat Dukenbayev
Kanat Dukenbayev
MSMadina Shaimerdenova
Madina Shaimerdenova
IBIldar Bekniyazov
Ildar Bekniyazov
TATakhmina Ayupova
Takhmina Ayupova
Daniele TosiDaniele Tosi
Daniele Tosi
A biosensor based on an etched Fiber Bragg Grating (EFBG) for thrombin detection is reported. The sensing system is based on a Fiber Bragg Grating (FBG) with a Bragg wavelength of 1550 nm, wet-etched in hydrofluoric acid (HF) for ~27 min, to achieve sensitivity to a refractive index (RI) of 17.4 nm/RIU (refractive index unit). Subsequently, in order to perform a selective detection of thrombin, the EFBG has been functionalized with silane-coupling agent 3-(aminopropyl)triethoxysilane (APTES) and a cross-linker, glutaraldehyde, for the immobilization of thrombin-binding aptamer. The biosensor has been validated for thrombin detection in concentrations ranging from 10 nM to 80 nM. The proposed sensor presents advantages with respect to other sensor configurations, based on plasmonic resonant tilted FBG or Long Period Grating (LPG), for thrombin detection. Firstly, fabricating an EFBG only requires chemical etching. Moreover, the functionalization method used in this study (silanization) allows the avoidance of complicated and expensive fabrications, such as thin film sputtering or chemical vapor deposition. Due to their characteristics, EFBG sensors are easier to multiplex and can be used in vivo. This opens new possibilities for the detection of thrombin in clinical settings.

17 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Aizhan IssatayevaAizhan Issatayeva
Aizhan Issatayeva
ABAidana Beisenova
Aidana Beisenova
Daniele TosiDaniele Tosi
Daniele Tosi
CMCarlo Molardi
Carlo Molardi
Wearable light textiles are gaining widespread interest in application for measurement and monitoring of biophysical parameters. Fiber optic sensors, in particular Bragg Grating (FBG) sensors, can be a competitive method for monitoring of respiratory behavior for chest and abdomen regions since the sensors are able to convert physical movement into wavelength shift. This study aims to show the performance of elastic belts with integrated optical fibers during the breathing activities done by two volunteers. Additionally, the work aims to determine how the positions of the volunteers affect the breathing pattern detected by optical fibers. As a reference, commercial mobile application for sensing vibration is used. The obtained results show that the FBGs are able to detect chest and abdomen movements during breathing and consequently reconstruct the breathing pattern. The accuracy of the results varies for two volunteers but remains consistent.

20 July 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Daniele TosiDaniele Tosi
Daniele Tosi
CMCarlo Molardi
Carlo Molardi
MSMarzhan Sypabekova
Marzhan Sypabekova
Wilfried BlancWilfried Blanc
Wilfried Blanc
Optical Backscatter Reflectometry (OBR) is an advanced distributed sensing technique that makes use of optical fibers to detect and localize physical parameters, with spatial resolution below the millimeter. By tailoring the Rayleigh scattering properties of optical fibers, enhancing the backscattering contents, we can create 2 and 3-dimensional sensing networks that can extend OBR to multi-dimensional sensing, and even to biosensing. In this work, we provide a tutorial on distributed optical fiber sensors with enhanced backscattering, and on how to design sensing networks with these fibers; we also review the main applications and emerging topics.