Increasing the image quality of positron emission tomography (PET) is an essential topic in the PET community. For instance, thin-pixelated crystals have been used to provide high spatial resolution images but at the cost of sensitivity and manufacture expense. In this paper, we proposed an approach to enhance the PET image resolution and noise property for PET scanners with large pixelated crystals. To address the problem of coarse blurred sinograms with large parallax errors associated with large crystals, we developed a data-driven, single-image superresolution (SISR) method for sinograms, based on the novel deep residual convolutional neural network (CNN). Unlike the CNN-based SISR on natural images, periodically padded sinogram data and dedicated network architecture were used to make it more efficient for PET imaging. Moreover, we included the transfer learning scheme in the approach to process cases with poor labeling and small training data set. The approach was validated via analytically simulated data (with and without noise), Monte Carlo simulated data, and pre-clinical data. Using the proposed method, we could achieve comparable image resolution and better noise property with large crystals of bin sizes 4 × of thin crystals with a bin size from 1 × 1 mm 2 to 1.6 × 1.6 mm 2 . Our approach uses external PET data as the prior knowledge for training and does not require additional information during inference. Meanwhile, the method can be added into the normal PET imaging framework seamlessly, thus potentially finds its application in designing low-cost high-performance PET systems.
13 December 2018 in IEEE Transactions on Instrumentation and Measurement
We present a nonuniform multiphase (NUMP) method to construct a high-resolution time-to-digital converter (TDC) for low-cost field-programmable gate array (FPGA) devices. The NUMP method involves a system clock being passed through a series of delay elements to generate multiple clocks with different phase shifts. The phases of the rising and falling edges of all the clocks are sorted in order and the states of all the clocks are latched when a hit signal arrives. The sizes of the time bins (and precision) of the NUMP method are not limited by the uniformity and minimum value of the time delays of the delay lines. In theory, any delay sources with small jitters in an FPGA, not just very fine carry chains, can be used in the NUMP method to delay and randomize the clocks. Thus, the NUMP method can achieve excellent TDC timing resolutions in low-cost FPGAs without very fine delay lines. We implemented four NUMP TDC channels in a low-cost FPGA device (an Altera Cyclone V 5CEBA4F23C7N). The performance of the four NUMP TDCs was evaluated using both internal and external pulses. The root mean square (rms) for the timing resolution measured using the internal and the external pulses with short-time intervals (less than 1 ns) was 2.3 and 5.2 ps, respectively. A 14.1-ps rms timing resolution was measured at a time interval of 517 ns. The NUMP method is suitable for applications that require a number of high-performance TDC channels in a low-cost FPGA.
Positron emission tomography (PET) is widely used in the diagnosis of tumors, cardiovascular system diseases, and neurological diseases. Scintillation crystals are an important part of PET scanners; they can convert γ photons into fluorescent photons to obtain their energy, time, and position information. Currently, an important research goal in PET is to find scintillation crystals with better performance. In this work, the principle of scintillation crystals is introduced, and the properties and requirements of scintillation crystals in different PET scanners are analyzed. At present, Lu2(1−x)Y2xSiO5 (LYSO) is the scintillation crystal with the best comprehensive properties. LaBr3 performs even better regarding the timing characteristics and light output; however, LaBr3 has not been used in any PET scanner because of its deliquescence. Detectors made of Gd3(Ga, Al)5O12 (GAGG) exhibit a high depth of interaction (DOI) resolution and have considerable application potential. The application fields of PET are constantly expanding, and its future development aims to achieve high spatial resolution and high sensitivity, which require scintillation crystals with better performance.
The performance of radiation detectors used in positron-emission tomography (PET) is determined by the intrinsic properties of the scintillators, the geometry and surface treatment of the scintillator crystals and the electrical and optical characteristics of the photosensors. Experimental studies were performed to assess the timing resolution and energy resolution of detectors constructed with samples of different scintillator materials (LaBr3, CeBr3, LFS, LSO, LYSO: Ce, Ca and GAGG) that were fabricated into different shapes with various surface treatments. The saturation correction of SiPMs was applied for tested detectors based on a Tracepro simulation. Overall, we tested 28 pairs of different forms of scintillators to determine the one with the best CTR and light output. Two common high-performance silicon photomultipliers (SiPMs) provided by SensL (J-series, 6 mm) or AdvanSiD (NUV, 6 mm) were used for photodetectors. The PET detector constructed with 6 mm CeBr3 cubes achieved the best CTR with a FWHM of 74 ps. The 4 mm co-doped LYSO: Ce, Ca pyramid crystals achieved 88.1 ps FWHM CTR. The 2 mm, 4 mm and 6 mm 0.2% Ce, 0.1% Ca co-doped LYSO cubes achieved 95.6 ps, 106 ps and 129 ps FWHM CTR, respectively. The scintillator crystals with unpolished surfaces had better timing than those with polished surfaces. The timing resolution was also improved by using certain geometric factors, such as a pyramid shape, to improve light transportation in the scintillator crystals.
15 November 2018 in IEEE Transactions on Instrumentation and Measurement
Reading out from large-scale silicon photomultiplier (SiPM) arrays is a fundamental technical obstacle blocking the application of revolutionary SiPM technologies in nuclear imaging systems. Typically, it requires using dedicated application-specific integrated circuits (ASICs) that need a long iterative process, special expertise, and tools to develop. The pico-positron emission tomography (Pico-PET) electronics system is an advanced 100-channel readout system based on 1-bit sigma-delta modulation and a field-programmable gate array (FPGA). It is compact (6 × 6 × 0.8 cm 3 in size), consumes little power (less than 3W), and is constructed with off-the-shelf low-cost components. In experimental studies, the Pico-PET system demonstrates excellent and consistent performance. In addition, it has some unique features that are essential for nuclear imaging systems, such as its ability to measure V-I curves, breakdown voltages, and the dark currents of 100 SiPMs accurately, simultaneously, and in real time. The flexibility afforded by FPGAs allows multiple-channel clustering and intelligent triggering for different detector designs. These highly sought-after features are not offered by any other ASICs and electronics systems developed for nuclear imaging. We conclude that the Pico-PET electronics system provides a practical solution to the long-standing bottleneck problem that has limited the development of potentially advanced nuclear imaging technology using SiPMs.
1 August 2007 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
A human-to-computer system that includes a wireless intra-oral module, a wireless coordinator and distributed wireless controllers, is presented. The state-of-the-art ZigBee protocol is employed to achieve reliable, low- power and cost-efficient wireless communication between the tongue, computer and controllers. By manipulating five buttons on the wireless intra-oral module using the tongue, the subject can control cursors, computer menus, wheelchair, lights, TV, phone and robotic devices. The system is designed to improve the life quality of patients with stroke and patients with spinal cord injury.