Xi Zhang

Dr. Xi Zhang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2022 in Crystals
Verified
Journal Article
Open access
PDF file
XYXin Yu
Xin Yu
Xi ZhangXi Zhang
Xi Zhang
HZHeng Zhang
Heng Zhang
HPHao Peng
Hao Peng
QRQiushi Ren
Qiushi Ren
SXSiwei Xie
Siwei Xie
Positron emission tomography (PET) is widely used in the diagnosis of tumors, cardiovascular system diseases, and neurological diseases. Scintillation crystals are an important part of PET scanners; they can convert γ photons into fluorescent photons to obtain their energy, time, and position information. Currently, an important research goal in PET is to find scintillation crystals with better performance. In this work, the principle of scintillation crystals is introduced, and the properties and requirements of scintillation crystals in different PET scanners are analyzed. At present, Lu2(1−x)Y2xSiO5 (LYSO) is the scintillation crystal with the best comprehensive properties. LaBr3 performs even better regarding the timing characteristics and light output; however, LaBr3 has not been used in any PET scanner because of its deliquescence. Detectors made of Gd3(Ga, Al)5O12 (GAGG) exhibit a high depth of interaction (DOI) resolution and have considerable application potential. The application fields of PET are constantly expanding, and its future development aims to achieve high spatial resolution and high sensitivity, which require scintillation crystals with better performance.

25 September 2020 in Crystals
Verified
Journal Article
Open access
PDF file
SXSiwei Xie
Siwei Xie
Xi ZhangXi Zhang
Xi Zhang
YZYibin Zhang
Yibin Zhang
GYGaoyang Ying
Gaoyang Ying
QHQiu Huang
Qiu Huang
QPQiyu Peng
Qiyu Peng
The performance of radiation detectors used in positron-emission tomography (PET) is determined by the intrinsic properties of the scintillators, the geometry and surface treatment of the scintillator crystals and the electrical and optical characteristics of the photosensors. Experimental studies were performed to assess the timing resolution and energy resolution of detectors constructed with samples of different scintillator materials (LaBr3, CeBr3, LFS, LSO, LYSO: Ce, Ca and GAGG) that were fabricated into different shapes with various surface treatments. The saturation correction of SiPMs was applied for tested detectors based on a Tracepro simulation. Overall, we tested 28 pairs of different forms of scintillators to determine the one with the best CTR and light output. Two common high-performance silicon photomultipliers (SiPMs) provided by SensL (J-series, 6 mm) or AdvanSiD (NUV, 6 mm) were used for photodetectors. The PET detector constructed with 6 mm CeBr3 cubes achieved the best CTR with a FWHM of 74 ps. The 4 mm co-doped LYSO: Ce, Ca pyramid crystals achieved 88.1 ps FWHM CTR. The 2 mm, 4 mm and 6 mm 0.2% Ce, 0.1% Ca co-doped LYSO cubes achieved 95.6 ps, 106 ps and 129 ps FWHM CTR, respectively. The scintillator crystals with unpolished surfaces had better timing than those with polished surfaces. The timing resolution was also improved by using certain geometric factors, such as a pyramid shape, to improve light transportation in the scintillator crystals.

1 August 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
JXJianfeng Xu
Jianfeng Xu
SXSiwei Xie
Siwei Xie
Xi ZhangXi Zhang
Xi Zhang
WTWeijie Tao
Weijie Tao
JYJingwu Yang
Jingwu Yang
QPQiyu Peng
Qiyu Peng
This paper presents a unique preclinical positron emission tomography (PET) detector constructed with a monolithic scintillator ring (MSR) and two rings of silicon photomultipliers (SiPM). The inner diameter, outer diameter and length of the MSR were 48.5 mm, 58.5 mm, and 25.1 mm, respectively. The two SiPM rings, constructed with 46 SiPMs, were air-coupled to the two ends of the MSR detector. The center of gravity (COG) and artificial neural network (ANN) methods were adapted to decode the positions of the gamma interactions in the circumferential ( θ ) and axial ( Z ) directions, respectively. Collimating systems, consisting of a tungsten collimator and a high-precision displacement and rotating platform, were constructed to assess the decoding accuracies of the MSR detector in both θ and Z directions. The average intrinsic full-width half maximums (FWHMs) and mean absolute errors (MAEs) of the decoding accuracies were 0.94 mm and 0.33 mm in the circumferential direction, 2.45 mm and 1.08 mm in the axial direction. An energy resolution of 10.7% was measured at 511 keV. The scintillating photons generated by a pair of coincidence gamma photons overlap with each other, and cause circumferential parallax errors in the lines of response (LOR). The experimental results show that the average FWHM errors in the θ direction increased slightly from 0.94 mm to 1.14 mm when Δ θ of the two single events was larger than 70°. The imaging performance of the MSR detector was also initially assessed with a Derenzo phantom filled with 18 F-FDG. The rods with a diameter larger than 1.2 mm can be resolved. The energy resolutions were 12.3% at 511 keV (single events), and 11.4% at 1022 keV (coincidence events). We concluded that it is feasible to construct the high-performance preclinical PET scanners using one or multiple MSR detectors.

11 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZSZhipeng Song
Zhipeng Song
ZZZhixiang Zhao
Zhixiang Zhao
HYHongsen Yu
Hongsen Yu
JYJingwu Yang
Jingwu Yang
Xi ZhangXi Zhang
Xi Zhang
QPQiyu Peng
Qiyu Peng
This paper presented a non-uniform multiphase (NUMP) time-to-digital converter (TDC) implemented in a field-programmable gate array (FPGA) with real-time automatic temperature compensation. NUMP-TDC is a novel, low-cost, high-performance TDC that has achieved an excellent performance in Altera Cyclone V FPGA. The root mean square (RMS) for the intrinsic timing resolution was 2.3 ps. However, the propagation delays in the delay chain of some FPGAs (for example, the Altera Cyclone 10 LP) vary significantly as the temperature changes. Thus, the timing performances of NUMP-TDCs implemented in those FPGAs are significantly impacted by temperature fluctuations. In this study, a simple method was developed to monitor variations in propagation delays using two registers deployed at both ends of the delay chain and compensate for changes in propagation delay using a look-up table (LUT). When the variations exceeded a certain threshold, the LUT for the delay correction was updated, and a bin-by-bin correction was launched. Using this correction approach, a resolution of 8.8 ps RMS over a wide temperature range (5 °C to 80 °C) had been achieved in a NUMP-TDC implemented in a Cyclone 10 LP FPGA.

1 July 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
Xi ZhangXi Zhang
Xi Zhang
HYHongsen Yu
Hongsen Yu
QXQiangqiang Xie
Qiangqiang Xie
SXSiwei Xie
Siwei Xie
BYBaihezi Ye
Baihezi Ye
QPQiyu Peng
Qiyu Peng
Preclinical positron emission tomography (PET) is a sensitive and quantitative molecule imaging modality widely used in characterizing the biological processes and diseases in small animals. The purpose of this study is to investigate the methods to optimize a PET detector for high-resolution preclinical imaging. The PET detector proposed in this study consists of a 28 × 28 array of LYSO crystals 0.5 × 0.5 × 6.25 mm 3 in size, a wedged lightguide, and a 6 × 6 array of SiPMs 3 × 3 mm 2 in size. The simulation results showed that the most uniform flood map was achieved when the thickness of the lightguide was 2.35 mm. The quality of the flood map was significantly improved by suppressing the electronics noises using the simple threshold method with a best threshold. The peak-to-valley ratio of flood map improved 25.4% when the algorithm of ICS rejection was applied. An energy resolution (12.96% ± 1.03%) was measured on the prototype scanner constructed with 12 proposed detectors. Lastly, a prototype preclinic PET imager was constructed with 12 optimized detectors. The point source experiment was performed and an excellent spatial resolution (axial: 0.56 mm, tangential: 0.46 mm, radial: 0.42 mm) was achieved with the proposed high-performance PET detectors.

8 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SXSiwei Xie
Siwei Xie
ZZZhiliang Zhu
Zhiliang Zhu
Xi ZhangXi Zhang
Xi Zhang
QXQiangqiang Xie
Qiangqiang Xie
HYHongsen Yu
Hongsen Yu
QPQiyu Peng
Qiyu Peng
As a commonly used solution, the multi-ended readout can measure the depth-of-interaction (DOI) for positron emission tomography (PET) detectors. In the present study, the effects of the multi-ended readout design were investigated using the leading-edge discriminator (LED) triggers on the timing performance of time-of-flight (TOF) PET detectors. At the very first, the photon transmission model of the four detectors, namely, single-ended readout, dual-ended readout, side dual-ended readout, and triple-ended readout, was established in Tracepro. The optical simulation revealed that the light output of the multi-ended readout was higher. Meanwhile, the readout circuit could be triggered earlier. Especially, in the triple-ended readout, the light output at 0.5 ns was observed to be nearly twice that of the single-ended readout after the first scintillating photon was generated. Subsequently, a reference detector was applied to test the multi-ended readout detectors that were constructed from a 6 × 6 × 25 mm3 LYSO crystal. Each module is composed of a crystal coupled with multiple SiPMs. Accordingly, its timing performance was improved by approximately 10% after the compensation of fourth-order polynomial fitting. Finally, the compensated full-width-at-half-maximum (FWHM) coincidence timing resolutions (CTR) of the dual-ended readout, side dual-ended readout, and triple-ended readout were 216.9 ps, 231.0 ps, and 203.6 ps, respectively.