Max Olender

Dr. Max Olender

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2019 in Science Translational Medicine
Verified
Journal Article
Open access
EBEyal Ben-Assa
Eyal Ben-Assa
JBJonathan Brown
Jonathan Brown
ZKZahra Keshavarz-Motamed
Zahra Keshavarz-Motamed
JHJose M. de la Torre Hernandez
Jose M. de la Torre Hernandez
BLBenjamin Leiden
Benjamin Leiden
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
High left ventricular stroke work and low vascular impedance predict better quality of life after valve intervention in patients with aortic stenosis.

15 June 2020 in IEEE Journal of Selected Topics in Signal Processing
Verified
Journal Article
Closed access
MOMax Olender
Max Olender
LALampros Athanasiou
Lampros Athanasiou
LMLampros K. Michalis
Lampros K. Michalis
Dimitrios FotiadisDimitrios Fotiadis
Dimitrios Fotiadis
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
Intravascular ultrasound (IVUS) imaging is widely used for diagnostic imaging in interventional cardiology. The detection and quantification of atherosclerosis from acquired images is typically performed manually by medical experts or by virtual histology IVUS (VH-IVUS) software. VH-IVUS analyzes backscattered radio frequency (RF) signals to provide a color-coded tissue map, and is the method of choice for assessing atherosclerotic plaque in situ. However, a significant amount of tissue cannot be analyzed in reasonable time because the method can be applied just once per cardiac cycle. Furthermore, only hardware and software compatible with RF signal acquisition and processing may be used. In this article, we present an image-based tissue characterization method that can be applied to entire acquisition sequences post hoc for the assessment of diseased vessels. The pixel-based method utilizes domain knowledge of arterial pathology and physiology, and leverages technological advances of convolutional neural networks to segment diseased vessel walls into the same tissue classes as virtual histology using only grayscale IVUS images. The method was trained and tested on patches extracted from VH-IVUS images acquired from several patients, and achieved overall accuracy of 93.5% for all segmented tissue. Imposing physically-relevant spatial constraints driven by domain knowledge was key to achieving such strong performance. This enriched approach offers capabilities akin to VH-IVUS without the constraints of RF signals or limited once-per-cycle analysis, offering superior potential information acquisition speed, reduced hardware and software requirements, and more widespread applicability. Such an approach may well yield promise for future clinical and research applications.

29 September 2021 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
KKKarim Kadry
Karim Kadry
MOMax Olender
Max Olender
DMDavid Marlevi
David Marlevi
EEElazer R. Edelman
Elazer R. Edelman
FNFarhad Nezami
Farhad Nezami
The pathophysiology of atherosclerotic lesions, including plaque rupture triggered by mechanical failure of the vessel wall, depends directly on the plaque morphology-modulated mechanical response. The complex interplay between lesion morphology and structural behaviour can be studied with high-fidelity computational modelling. However, construction of three-dimensional (3D) and heterogeneous models is challenging, with most previous work focusing on two-dimensional geometries or on single-material lesion compositions. Addressing these limitations, we here present a semi-automatic computational platform, leveraging clinical optical coherence tomography images to effectively reconstruct a 3D patient-specific multi-material model of atherosclerotic plaques, for which the mechanical response is obtained by structural finite-element simulations. To demonstrate the importance of including multi-material plaque components when recovering the mechanical response, a computational case study was conducted in which systematic variation of the intraplaque lipid and calcium was performed. The study demonstrated that the inclusion of various tissue components greatly affected the lesion mechanical response, illustrating the importance of multi-material formulations. This platform accordingly provides a viable foundation for studying how plaque micro-morphology affects plaque mechanical response, allowing for patient-specific assessments and extension into clinically relevant patient cohorts.

1 June 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MOMax Olender
Max Olender
LALampros Athanasiou
Lampros Athanasiou
JHJose M. de la Torre Hernandez
Jose M. de la Torre Hernandez
EBEyal Ben-Assa
Eyal Ben-Assa
FNFarhad Nezami
Farhad Nezami
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
Automated analysis of vascular imaging techniques is limited by the inability to precisely determine arterial borders. Intravascular optical coherence tomography (OCT) offers unprecedented detail of artery wall structure and composition, but does not provide consistent visibility of the outer border of the vessel due to limited penetration depth. Existing interpolation and surface fitting methods prove insufficient to accurately fill the gaps between the irregularly-spaced and sometimes unreliably-identified visible segments of the vessel outer border. This paper describes an intuitive, efficient, and flexible new method of three-dimensional surface fitting and smoothing suitable for this task. An anisotropic linear-elastic mesh is fit to irregularly-spaced and uncertain data points corresponding to visible segments of vessel borders, enabling the fully-automated delineation of the entire inner and outer borders of diseased vessels in OCT images for the first time. In a clinical dataset, the proposed smooth surface fitting approach had great agreement when compared to human annotations: areas differed by just 11±11% (0.93±0.84 mm2), with a coefficient of determination of 0.89. Overlapping and non-overlapping area ratios were 0.91 and 0.18, respectively, with sensitivity of 90.8 and specificity of 99.0. This spring mesh method of contour fitting significantly outperformed all alternative surface fitting and interpolation approaches tested. The application of this promising proposed method is expected to enhance clinical intervention and translational research using OCT.

26 February 2022 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
MOMax Olender
Max Olender
YNYanan Niu
Yanan Niu
DMDavid Marlevi
David Marlevi
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
FNFarhad Nezami
Farhad Nezami

7 June 2021 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
PDF file
MOMax Olender
Max Olender
JHJosé M de la Torre Hernández
José M de la Torre Hernández
LALampros Athanasiou
Lampros Athanasiou
FNFarhad Nezami
Farhad Nezami
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
Artificial intelligence (AI) offers great promise in cardiology, and medicine broadly, for its ability to tirelessly integrate vast amounts of data. Applications in medical imaging are particularly attractive, as images are a powerful means to convey rich information and are extensively utilized in cardiology practice. Departing from other AI approaches in cardiology focused on task automation and pattern recognition, we describe a digital health platform to synthesize enhanced, yet familiar, clinical images to augment the cardiologist’s visual clinical workflow. In this article, we present the framework, technical fundamentals, and functional applications of the methodology, especially as it pertains to intravascular imaging. A conditional generative adversarial network was trained with annotated images of atherosclerotic diseased arteries to generate synthetic optical coherence tomography and intravascular ultrasound images on the basis of specified plaque morphology. Systems leveraging this unique and flexible construct, whereby a pair of neural networks is competitively trained in tandem, can rapidly generate useful images. These synthetic images replicate the style, and in several ways exceed the content and function, of normally acquired images. By using this technique and employing AI in such applications, one can ameliorate challenges in image quality, interpretability, coherence, completeness, and granularity, thereby enhancing medical education and clinical decision-making.