Eyal Ben-Assa

Eyal Ben-Assa

Auto-generated profile, based on publicly available information

Eyal Ben-Assa

Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
EBEyal Ben-Assa
Eyal Ben-Assa
PRPablo Rengifo-Moreno
Pablo Rengifo-Moreno
RARasha Al-Bawardy
Rasha Al-Bawardy
DKDhaval Kolte
Dhaval Kolte
RCRicardo Cigarroa
Ricardo Cigarroa
IPIgor F. Palacios
Igor F. Palacios

11 September 2019 in Science Translational Medicine
Verified
Journal Article
Open access
EBEyal Ben-Assa
Eyal Ben-Assa
JBJonathan Brown
Jonathan Brown
ZKZahra Keshavarz-Motamed
Zahra Keshavarz-Motamed
JHJose M. de la Torre Hernandez
Jose M. de la Torre Hernandez
BLBenjamin Leiden
Benjamin Leiden
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
High left ventricular stroke work and low vascular impedance predict better quality of life after valve intervention in patients with aortic stenosis.

27 October 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
LALampros Athanasiou
Lampros Athanasiou
FNFarhad Nezami
Farhad Nezami
MGMicheli Zanotti Galon
Micheli Zanotti Galon
ALAugusto Celso Lopes
Augusto Celso Lopes
PLPedro Alves Lemos
Pedro Alves Lemos
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
We present a novel and time-efficient method for intracoronary lumen detection, which produces three-dimensional (3-D) coronary arteries using optical coherence tomographic (OCT) images. OCT images are acquired for multiple patients and longitudinal cross-section (LOCS) images are reconstructed using different acquisition angles. The lumen contours for each LOCS image are extracted and translated to 2-D cross-sectional images. Using two angiographic projections, the centerline of the coronary vessel is reconstructed in 3-D, and the detected 2-D contours are transformed to 3-D and placed perpendicular to the centerline. To validate the proposed method, 613 manual annotations from medical experts were used as gold standard. The 2-D detected contours were compared with the annotated contours, and the 3-D reconstructed models produced using the detected contours were compared to the models produced by the annotated contours. Wall shear stress (WSS), as dominant hemodynamics factor, was calculated using computational fluid dynamics and 844 consecutive 2-mm segments of the 3-D models were extracted and compared with each other. High Pearson's correlation coefficients were obtained for the lumen area (r = 0.98) and local WSS (r = 0.97) measurements, while no significant bias with good limits of agreement was shown in the Bland-Altman analysis. The overlapping and nonoverlapping areas ratio between experts' annotations and presented method was 0.92 and 0.14, respectively. The proposed computer-aided lumen extraction and 3-D vessel reconstruction method is fast, accurate, and likely to assist in a number of research and clinical applications.

28 September 2016 in Cardiovascular Therapeutics
Verified
Journal Article
Open access
PDF file
Ofer HavakukOfer Havakuk
Ofer Havakuk
MKMaayan Konigstein
Maayan Konigstein
EAEyal Ben Assa
Eyal Ben Assa
YAYaron Arbel
Yaron Arbel
YAYigal Abramowitz
Yigal Abramowitz
SBShmuel Banai
Shmuel Banai
Summary: Background: Direct mechanical compression of the frame struts on the adjacent bundle branch with local inflammatory reaction might cause conduction system disturbances and need for pacemaker implantation following transcatheter aortic valve implantation (TAVI). We assessed the impact of preprocedural anti‐inflammatory steroid therapy on the occurrence of conduction disturbances following TAVI.Methods and results: From a cohort of 324 patients who underwent transfemoral TAVI, 39 (12%) were pretreated with steroids because of iodine allergy (n=29) or active obstructive pulmonary disease (n=10). We compared the rate of occurrence of new conduction disturbances and pacemaker implantation between TAVI patients with (n=39) and without (n=285) steroid treatment, using Cox logistic regression estimates and proportional hazards models. The overall occurrence of new conduction defects and the need for new pacemaker implantation were similar among steroid and non‐steroid‐treated patients (38.4% vs 37.5% and 25.6% vs 25.3%, respectively). New conduction disturbances were more prevalent in patients treated with CoreValve prosthesis, low implantation, and smaller aortic annulus diameter (P<.001, P<.001, and P=.006, respectively). Thirty‐day mortality and complication rates were similar between the groups.Conclusion: Although safe, steroid treatment prior to TAVI failed to reduce the incidence of new conduction defects and the need for pacemaker implantation.

16 June 2021 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
EBEyal Ben‐Assa
Eyal Ben‐Assa
JHJesús Herrero‐Garibi
Jesús Herrero‐Garibi
ICIgnacio Cruz-Gonzalez
Ignacio Cruz-Gonzalez
SESammy Elmariah
Sammy Elmariah
PRPablo Rengifo‐Moreno
Pablo Rengifo‐Moreno
IPIgor F. Palacios
Igor F. Palacios

20 January 2020 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
GLGiuseppe Di Labbio
Giuseppe Di Labbio
EAEyal Ben Assa
Eyal Ben Assa
LKLyes Kadem
Lyes Kadem
There is much debate in the literature surrounding the effects of heart rate on aortic regurgitation (AR). Despite the contradictory information, it is still widely believed that an increase in heart rate is beneficial due to the disproportionate shortening of the duration of diastole relative to systole, permitting less time for the left ventricle to fill from regurgitation. This in vitro work investigates how a change in heart rate affects the left ventricular fluid dynamics in the absence and presence of acute AR. The experiments are performed on a novel double-activation left heart simulator previously used for the study of chronic AR. The intraventricular velocity fields are acquired via time-resolved planar particle image velocimetry (PIV) in a clinically relevant plane. Considering fluid dynamic factors, an increase in heart rate was observed to have a limited benefit in the case of mild AR and a detrimental effect for more severe AR. With increasing heart rate, mild AR was associated with a decrease in regurgitant volume, a negligible change in regurgitant volume per diastolic second, and a limited reduction in the fraction of retained regurgitant inflow. More severe AR was accompanied by an increase in both regurgitant volume and the fraction of retained regurgitant inflow, implying a less effective pumping efficiency and a longer relative residence time of blood in the ventricle. Globally, the left ventricle's capacity to compensate for the increase in energy dissipation associated with an increase in heart rate diminishes considerably with severity, a phenomenon which may be exploited further as a method of noninvasive assessment of the severity of AR. These findings may affect the clinical belief that tachycardia is preferred in acute AR and should be investigated further in the clinical setting.