Traditional beamforming (BF) methods can be used to suppress the Gaussian interferers in underwater acoustic communication systems. However, multiple unsteady sub-Gaussian interferers may exist that degrade the performance of traditional BF. In this paper, a new beamformer is proposed for the suppression of multiple unsteady sub-Gaussian interferers (SMUSGI). The proposed BF combines the multiplier and the quasi-Newton methods to obtain the optimal weight vector. Simulation experiments are conducted to validate the performance of the proposed beamformer. In addition, the proposed beamformer is compared with the traditional methods including the MVDR, Subspace, Bartlett, MDDR, LCMD and LCMV beamformers. The obtained results demonstrate that the proposed beamformer can effectively suppress multiple unsteady sub-Gaussian interferers with a higher output signal-to-interference-plus-noise ratio (SINR), and faster convergence compared with the traditional methods.
A hybrid optical-acoustic underwater wireless sensor network (OA-UWSN) was proposed to solve the problem of high-speed transmission of real-time video and images in marine information detection. This paper proposes a novel energy-efficient contention-based media access control (MAC) protocol (OA-CMAC) for the OA-UWSN. Based on optical-acoustic fusion technology, our proposed OA-CMAC combines the postponed access mechanism in carrier sense multiple access with collision avoidance (CSMA/CA) and multiplexing-based spatial division multiple access (SDMA) technology to achieve high-speed and real-time data transmission. The protocol first performs an acoustic handshake to obtain the location information of a transceiver node, ensuring that the channel is idle. Otherwise, it performs postponed access and waits for the next time slot to contend for the channel again. Then, an optical handshake is performed to detect whether the channel condition satisfies the optical transmission, and beam alignment is performed at the same time. Finally, the nodes transmit data using optical communication. If the channel conditions do not meet the requirements for optical communication, a small amount of data with high priority is transmitted through acoustic communication. An evaluation of the proposed MAC protocol was performed with OMNeT++ simulations. The results showed that when the optical handshaking success ratio was greater than 50%, compared to the O-A handshake protocol in the literature, our protocol could result in doubled throughput. Due to the low energy consumption of optical communication, the node’s lifetime is 30% longer than that of pure acoustic communication, greatly reducing the network operation cost. Therefore, it is suitable for large-scale underwater sensor networks with high loads.
The production profile logging technology of Oil-water two-phase flow is an important support technology for efficient development of horizontal oil wells. Moreover, the water holdup of Oil-water two-phase flow is one of the important dynamic measurement parameters for production profile logging technology. Flow patterns in horizontal oil wells are more complex than those in vertical oil wells, making water holdup measurements more difficult. In China, horizontal oil wells are characterized by low liquid production, high water cut and layered development; hence, the concentrating flow logging scheme is adopted to reduce the effects of flow patterns on measurement. In this paper, we proposed a new method of measuring water holdup of Oil-water two-phase flow for the production profile logging in horizontal oil wells. Firstly, the structure of water holdup sensors and the measuring principle of water holdup were introduced. Secondly, the dynamic test research was carried out on the horizontal well simulation facility by using the test prototype of the water holdup measurement method of Oil-water two-phase flow. Additionally, the response characteristics of water holdup sensors at five inclined angles were emphatically discussed. Finally, the measurement error of water holdup was calculated and evaluated in detail. Experimental results show that the absolute values of measurement error of water holdup are less than 5% while the total flow rate ranged from 10 m3/d to 200 m3/d, and the water cut ranged from 30% to 90%, respectively.