Artur Tadeusz Cebula

Prof. Dr. Artur Tadeusz Cebula

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
ACArtur Tadeusz Cebula
Artur Tadeusz Cebula
Jan TalerJan Taler
Jan Taler
Paweł OcłońPaweł Ocłoń
Paweł Ocłoń


1 January 2014
Verified
Book Chapter
Closed access
PDF file
ACArtur Tadeusz Cebula
Artur Tadeusz Cebula
Dawid TalerDawid Taler
Dawid Taler

10 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
DLDamian Liszka
Damian Liszka
ZKZbigniew Krzemianowski
Zbigniew Krzemianowski
Tomasz WegielTomasz Wegiel
Tomasz Wegiel
Dariusz BorkowskiDariusz Borkowski
Dariusz Borkowski
APAndrzej Polniak
Andrzej Polniak
ACArtur Tadeusz Cebula
Artur Tadeusz Cebula
Obtaining energy from renewable resources is a worldwide trend in the age of increasing energy demand. Hydropower has some potential in this field, especially for low-power locations. However, construction of such facilities requires high expenses, which is why some attempts at lowering the costs have been made, i.e., by proposing alternative solutions to the classic ones. This paper proposes a selection of options for small hydropower plants (SHP) that lower the investment costs while keeping up profitable operations. The proposed solutions concern simplifying the turbine’s and generator’s integration by installing them in dedicated prefabricated concrete modules. A rare but simple and cheap semi-Kaplan type of turbine with a non-classical spiral inflow is proposed. The turbine operates a permanent magnet (PM)-excited generator, converting the energy at a variable rotational speed. Thanks to this approach, it is possible to simplify the regulation system and eliminate expensive mechanical transmission. However, on the power grid side, a power electronic converter (PEC) must be coupled with the generator. The advantage of this solution compared to the classical ones is that the reliability of power electronics is much higher than that of mechanical systems. This paper presents modeling research on semi-Kaplan turbines’ series development, and a dedicated PM generator is presented as an example of a complete hydro unit with 50 kW power.

12 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
WZWiesław Zima
Wiesław Zima
ACArtur Tadeusz Cebula
Artur Tadeusz Cebula
PCPiotr Cisek
Piotr Cisek
The paper presents a one-dimensional distributed parameter model for simulating the transient-state operation of a parabolic trough collector (PTC). The analyzed solar collector has a module design and is equipped with a two-axis sun-tracking system to increase the solar energy yield. The single module is composed of an evacuated tube and a set of parabolic mirrors acting as reflectors. In each of the collector tubes, two aluminum U-tubes are installed, enabling heat intake by the solar fluid. The collector is intended for household applications, as well as other medium thermal energy demand uses. During the numerical model development, appropriate energy balance differential equations are formulated for the collector individual components. The equations are solved using different schemes. As a result, a time- and space-dependent temperature series for each of the collector components and the working fluid are obtained. To select an appropriate time and spatial steps for the developed model and to verify the reliability of the results received, the collector model is also implemented in ANSYS Fluent. The results of the one-dimensional model calculations and comparisons carried out in ANSYS demonstrate considerable agreement. In particular, the values of the fluid temperature at the collector outlet, calculated using the model developed, show high consistency with the ANSYS Fluent results. Furthermore, a preliminary experimental verification of the proposed model is carried out on a test stand currently under construction. The computed and measured temperature course of the fluid at the collector outlet is compared. In this case, the results are also satisfactory.

30 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
BRBartosz Rozegnał
Bartosz Rozegnał
PAPawel Albrechtowicz
Pawel Albrechtowicz
DMDominik Mamcarz
Dominik Mamcarz
Natalia Julia Radwan-PragłowskaNatalia Julia Radwan-Pragłowska
Natalia Julia Radwan-Pragłowska
ACArtur Tadeusz Cebula
Artur Tadeusz Cebula
Single-phase short-circuits are most often faults in electrical systems. The analysis of this damage type is taken for backup power supply systems, from small power synchronous generators. For these hybrid installations, there is a need for standard protection devices, such as fuses or miniature circuit breaker (MCB) analysis. Experimental research mentioned that a typical protective apparatus in low-voltage installations, working correctly during supplying from the grid, does not guarantee fast off-switching, while short-circuits occur during supplication from the backup generator set. The analysis of single-phase short-circuits is executed both for current waveform character (including sub-transient and transient states) and the carried energy, to show the problems with the fuses and MCB usage, to protect circuits in installations fed in a hybrid way (from the grid and synchronous generator set).