This paper presents the skin effect impact on the active power losses in the sheathless single-core cables/wires supplying nonlinear loads. There are significant conductor losses when the current has a distorted waveform (e.g., the current supplying diode rectifiers). The authors present a new method for active power loss calculation. The obtained results have been compared to the IEC-60287-1-1:2006 + A1:2014 standard method and the method based on the Bessel function. For all methods, the active power loss results were convergent for small-cable cross-section areas. The proposed method gives smaller power loss values for these cable sizes than the IEC and Bessel function methods. For cable cross-section areas greater than 185 mm2, the obtained results were better than those for the other methods. There were also analyses of extra power losses for distorted currents compared to an ideal 50 Hz sine wave for all methods. The new method is based on the current penetration depth factor calculated for every considered current harmonics, which allows us to calculate the precise equivalent resistance for any cable size. This research is part of our work on a cable thermal analysis method that has been developed.
Phase shifting transformers (PSTs) are currently widely used in power systems to control power flow. In this manuscript, the results of the asymmetrical PST (APST) with the in-phase PST (called asymmetrical controllable PST-ACPST) were compared, allowing to control both longitudinal and quadrature voltage. The MATLAB simulation model of the ACPST was built to obtain influence of PST in selected models for selected parameters. Then the 30A laboratory PST device was built in the laboratory. The parameters of the MATLAB model were then adjusted to parameters of the real life PST model. This allowed verifying the results of the real life and computer simulations. Based on the ACPST simulation model, the APST model was built; for the given work conditions, the influence of both PSTs were compared. APST construction always resulted in higher output voltage than the input one. ACPST achieved the same power transfer for the lower output PST voltage, which is its main advantage. This dependency is a result of the greater ACPST angle compared to the classical APST. The ACPST also allowed adjusting longitudinal and quadrature voltages; therefore, this PST type can be installed in places where high flexibility is required, especially in systems with high renewable energy sources penetration.
Single-phase short-circuits are most often faults in electrical systems. The analysis of this damage type is taken for backup power supply systems, from small power synchronous generators. For these hybrid installations, there is a need for standard protection devices, such as fuses or miniature circuit breaker (MCB) analysis. Experimental research mentioned that a typical protective apparatus in low-voltage installations, working correctly during supplying from the grid, does not guarantee fast off-switching, while short-circuits occur during supplication from the backup generator set. The analysis of single-phase short-circuits is executed both for current waveform character (including sub-transient and transient states) and the carried energy, to show the problems with the fuses and MCB usage, to protect circuits in installations fed in a hybrid way (from the grid and synchronous generator set).