Tomáš Basarik

Mr. Tomáš Basarik

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2025
Verified
Book Chapter
Closed access
PDF file
TKTadeáš Kmecik
Tadeáš Kmecik
TBTomáš Basarik
Tomáš Basarik
DGDaniel Gordan
Daniel Gordan
Peter GirovskýPeter Girovský
Peter Girovský
MLMilan Lacko
Milan Lacko

20 May 2024
Verified
Conference Paper
Closed access
TBTomáš Basarik
Tomáš Basarik
MLMilan Lacko
Milan Lacko
MPMarek Pástor
Marek Pástor
DGDaniel Gordan
Daniel Gordan
TKTadeáš Kmecik
Tadeáš Kmecik
The equivalent circuit of the transformer is an abstract model that describes the real behavior of the transformer. Today, several equivalent circuits are known. The most well-known are the T-equivalent circuit and the $\Pi$ -equivalent circuit that derives from it. Parameters are typically estimated by nameplate nominal parameters, short-circuit, open-circuit measurements, etc. In this procedure, the simplifications used introduce inaccuracies into the estimate. This paper describes an iterative method that minimizes inaccuracy.

15 July 2025
Verified
Book Chapter
Closed access
PDF file
DGDaniel Gordan
Daniel Gordan
MPMarek Pástor
Marek Pástor
TBTomáš Basarik
Tomáš Basarik
TKTadeáš Kmecik
Tadeáš Kmecik

1 January 2026 in Power Electronics and Drives
Verified
Journal Article
Open access
PDF file
TBTomáš Basarik
Tomáš Basarik
TKTadeáš Kmecik
Tadeáš Kmecik
DGDaniel Gordan
Daniel Gordan
MLMilan Lacko
Milan Lacko
Karol KyslanKarol Kyslan
Karol Kyslan
AGAnna Grincova
Anna Grincova
Modern energy systems require efficient power management, making multi-active bridge (MAB) converters ideal for electric vehicle (EV) charging and DC microgrids. However, higher port counts lead to magnetic coupling and non-linear dynamics, complicating independent control. This paper proposes a generalised power flow decoupling strategy for a five-port modular multi-active bridge (MMAB) converter using the Newton–Raphson (NR) method. Unlike traditional reduced-order models, a current-based model is employed to maintain modularity. A key contribution is the integration of the Moore–Penrose pseudoinverse into the NR solver to mitigate Jacobian singularities and ensure numerical stability. The algorithm is implemented on a dual-core central processing unit (CPU), achieving a deterministic 40 μs execution time. Furthermore, this study identifies performance degradation caused by parasitic inductances in the modular AC bus and proposes an optimised design using magnetic flux cancellation. Modelling precision is further refined through offline fast Fourier transform (FFT)-based parameter identification. Experimental validation on a five-port MMAB prototype confirms that the proposed method provides superior steady-state accuracy and robust dynamic decoupling during rapid transient load transitions.

11 August 2026 in Mathematics
Verified
Journal Article
Open access
PDF file
MLMilan Lacko
Milan Lacko
MPMarek Pástor
Marek Pástor
Peter GirovskýPeter Girovský
Peter Girovský
JŽJaroslava Žilková
Jaroslava Žilková
TBTomáš Basarik
Tomáš Basarik
This paper presents the mathematical modeling, numerical implementation, and experimental validation of a decoupling control algorithm for a five-port multiport modular active bridge (MMAB) converter in DC microgrid applications. Based on an analytically derived generalized state-space framework of the MMAB topology, a matrix-based method for suppressing non-linear mutual cross-couplings among individual ports is proposed. The study addresses parametric uncertainties within the system matrix caused by parasitic bus inductances; by formulating a linear system of equations solved via the numerical least-squares method, the equivalent parameter identification error was reduced from over 18% to a valid threshold. The decoupling performance and dynamic responsiveness of the closed-loop system were experimentally verified on a dual-core TMS320F28379D digital signal processor. The experimental results demonstrate that the proposed algorithm effectively isolates transient step-load perturbations, maintaining voltage stability on adjacent undisturbed ports within a strict deviation of less than +0.51% and achieving a recovery time below 5 ms. Furthermore, the real-time execution of the online Jacobian matrix inversion via the Newton–Raphson method confirms the computational feasibility and convergence of the iterative approach under tight sampling periods. The obtained results provide a robust, experimentally validated foundation for advanced algebraic and numerical control strategies in high-stability multiport power conversion systems.

7 August 2024 in Automatika
Verified
Journal Article
Open access
MPMarek Pástor
Marek Pástor
DGDaniel Gordan
Daniel Gordan
TBTomáš Basarik
Tomáš Basarik
CMCHIEMEKA LOVETH MAXWELL
CHIEMEKA LOVETH MAXWELL