To address the high computational cost of full-domain transient simulations of heat pipe-assisted phase change energy storage systems for vehicle engine exhaust waste heat recovery, this paper proposes a space-time dual decoupling method. Dimensional analysis reveals significant time-scale disparities between the fast and slow sub-domains of the system, on the basis of which the full-domain transient model is sequentially decoupled into a steady-state calibration of the fast sub-domain and a transient evolution of the slow sub-domain. Multiple steady-state calculations are first performed to calibrate an explicit mapping between the recovered heat power and the wall temperature; this mapping is then imposed as a time-varying heat-flux boundary condition to drive the independent transient evolution of the heat storage process. The results show that the fast sub-domain reaches a quasi-steady state within 20 s, with the energy balance deviation decreasing from 38.5% to below 5%. The predicted heat pipe wall temperatures and recovered heat powers agree closely with those of the traditional full-domain transient method, with maximum relative errors of 1.2% and 5.54%, respectively, while the total computational time is reduced from 4364.54 h to 147.99 h, corresponding to an approximately 29.5-fold improvement in efficiency.
Laminar counterflow multi-branch flames provide a canonical configuration for investigating interactions between oxidizer-rich and fuel-rich streams in liquid-oxygen/methane combustion systems. This study numerically investigates their flame structure and stability under transcritical conditions, with stability characterized by the extinction strain rate. Ideal-fluid (IF), partial real-fluid (PRF), and real-fluid (RF) models are compared to distinguish the effects of real-fluid thermodynamics and high-pressure transport corrections. The multi-branch flame comprises two premixed branches coupled with a central diffusion branch. Heat release from the premixed branches creates high-temperature plateaus that preheat the stagnation-region mixture and sustain the diffusion branch. Although the three models predict similar flame topologies, the IF model gives an extinction strain rate of , whereas both PRF and RF predict . Thus, the ideal-fluid treatment slightly overpredicts the extinction limit under the present reference condition, while high-pressure transport corrections influence the ignition location, peak temperature, and thermal diffusivity. Increasing pressure from 10 MPa to 40 MPa raises the extinction strain rate from to by strengthening heat release and reducing thermal diffusion from the high-temperature region. Oxidizer preheating markedly enhances flame stability, whereas fuel preheating has a weak effect. These findings establish the connection between real-fluid thermodynamics, branch interaction, and extinction stability, providing a physical basis for model selection, operating-condition optimization, and stability-margin assessment in transcritical liquid-oxygen/methane combustion systems.