Activity recognition, as an important component of behavioral monitoring and intervention, has attracted enormous attention, especially in Mobile Cloud Computing (MCC) and Remote Health Monitoring (RHM) paradigms. While recently resource constrained wearable devices have been gaining popularity, their battery life is limited and constrained by the frequent wireless transmission of data to more computationally powerful back-ends. This paper proposes an ultra-low power activity recognition system using a novel adaptive compressed sensing technique that aims to minimize transmission costs. Coarse-grained on-body sensor localization and unsupervised clustering modules are devised to autonomously reconfigure the compressed sensing module for further power saving. We perform a thorough heuristic optimization using Grammatical Evolution (GE) to ensure minimal computation overhead of the proposed methodology. Our evaluation on a real-world dataset and a low power wearable sensing node demonstrates that our approach can reduce the energy consumption of the wireless data transmission up to 81.2% and 61.5%, with up to 60.6% and 35.0% overall power savings in comparison with baseline and a naive state-of-the-art approaches, respectively. These solutions lead to an average activity recognition accuracy of 89.0% only 4.8% less than the baseline accuracy-while having a negligible energy overhead of on-node computation.
5 January 2018 in IEEE Transactions on Mobile Computing
Wearable technologies play a central role in human-centered Internet-of-Things applications. Wearables leverage machine learning algorithms to detect events of interest such as physical activities and medical complications. A major obstacle in large-scale utilization of current wearables is that their computational algorithms need to be re-built from scratch upon any changes in the configuration. Retraining of these algorithms requires significant amount of labeled training data, a process that is labor-intensive and time-consuming. We propose an approach for automatic retraining of the machine learning algorithms in real-time without need for any labeled training data. We measure the inherent correlation between observations made by an old sensor view for which trained algorithms exist and the new sensor view for which an algorithm needs to be developed. Our multi-view learning approach can be used in both online and batch modes. By applying the autonomous multi-view learning in the batch mode, we achieve an accuracy of 83.7% in activity recognition which is an improvement of 9.3% due to the automatic labeling of the data in the new sensor node. In addition to gain the less computation advantage of incremental training, the online learning algorithm results in an accuracy of 82.2% in activity recognition.
Background: Previous research has highlighted the role of stress in substance misuse and addiction, particularly for relapse risk. Mobile health interventions that incorporate real-time monitoring of physiological markers of stress offer promise for delivering tailored interventions to individuals during high-risk states of heightened stress to prevent alcohol relapse. Before such interventions can be developed, measurements of these processes in ambulatory, real-world settings are needed. Objective: This research is a proof-of-concept study to establish the feasibility of using a wearable sensor device to continuously monitor stress in an ambulatory setting. Toward that end, we first aimed to examine the quality of 2 continuously monitored physiological signals—electrodermal activity (EDA) and heart rate variability (HRV)—and show that the data follow standard quality measures according to the literature. Next, we examined the associations between the statistical features extracted from the EDA and HRV signals and self-reported outcomes. Methods: Participants (N=11; female: n=10) were asked to wear an Empatica E4 wearable sensor for continuous unobtrusive physiological signal collection for up to 14 days. During the same time frame, participants responded to a daily diary study using ecological momentary assessment of self-reported stress, emotions, alcohol-related cravings, pain, and discomfort via a web-based survey, which was conducted 4 times daily. Participants also participated in structured interviews throughout the study to assess daily alcohol use and to validate self-reported and physiological stress markers. In the analysis, we first used existing artifact detection methods and physiological signal processing approaches to assess the quality of the physiological data. Next, we examined the descriptive statistics for self-reported outcomes. Finally, we investigated the associations between the features of physiological signals and self-reported outcomes. Results: We determined that 87.86% (1,032,265/1,174,898) of the EDA signals were clean. A comparison of the frequency of skin conductance responses per minute with previous research confirmed that the physiological signals collected in the ambulatory setting were successful. The results also indicated that the statistical features of the EDA and HRV measures were significantly correlated with the self-reported outcomes, including the number of stressful events marked on the sensor device, positive and negative emotions, and experienced pain and discomfort. Conclusions: The results demonstrated that the physiological data collected via an Empatica E4 wearable sensor device were consistent with previous literature in terms of the quality of the data and that features of these physiological signals were significantly associated with several self-reported outcomes among a sample of adults diagnosed with alcohol use disorder. These results suggest that ambulatory assessment of stress is feasible and can be used to develop tailored mobile health interventions to enhance sustained recovery from alcohol use disorder.
27 December 2019 in IEEE Journal of Biomedical and Health Informatics
We introduce a novel approach for robust estimation of physiological parameters such as interbeat interval (IBI) and heart rate variability (HRV) from cardiac signals captured with wearable sensors in the presence of motion artifacts. Motion artifact due to physical exercise is known as a major source of noise that contributes to a significant decline in the performance of IBI and HRV estimation techniques for cardiac monitoring in free-living environments. Therefore, developing robust estimation algorithms is essential for utilization of wearable sensors in daily life situations. The proposed approach includes two algorithmic components. First, we propose a combinatorial technique to select characteristic points that define heartbeats in noisy signals in time domain. The heartbeat detection problem is defined as a shortest path search problem on a direct acyclic graph that leverages morphological features of the cardiac signals by taking advantage of the time-continuity of heartbeats - each heartbeat ends with the starting point of the next heartbeat. The graph is constructed with vertices and edges representing candidate morphological features and IBIs, respectively. Second, we propose a fusion technique to combine physiological parameters estimated from different morphological features using the shortest path algorithm to obtain more accurate IBI/HRV estimations. We evaluate our techniques on motion-corrupted photoplethysmogram and electrocardiogram signals. Our results indicate that the estimated IBIs are highly correlated with the ground truth (r = 0.89) and detected HRV parameters indicate high correlation with the true HRV parameters. Furthermore, our findings demonstrate that the developed fusion technique, which utilizes different morphological features, achieves a correlation coefficient that is at least 3% higher than that obtained using single physiological characteristic.