Manuel Barragán-Villarejo

Dr. Manuel Barragán-Villarejo

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2012 in IET Renewable Power Generation
Verified
Journal Article
Closed access
JOJose Maria Maza Ortega
Jose Maria Maza Ortega
AGA. GómEz-ExpósIto
A. GómEz-ExpósIto
MBManuel Barragán-Villarejo
Manuel Barragán-Villarejo
ERE. Romero Ramos
E. Romero Ramos
AMAlejandro Marano-Marcolini
Alejandro Marano-Marcolini
This study presents and thoroughly compares different alternatives to create DC links in distribution networks by means of voltage source converters (VSC). Such links give rise to fully controllable loops in nowadays radially operated systems, allowing higher levels of distributed generation penetration. Suitable VSC-based devices are reviewed and compared from several points of view, including topologies, degrees of freedom, operating ranges and performance. Several case studies, involving actual urban and rural distribution networks, are worked out to show the potential benefits provided by the use of the proposed smart links.

1 July 2021 in Fusion Engineering and Design
Verified
Journal Article
Open access
MAM. Agredano-Torres
M. Agredano-Torres
JGJ.L. Garcia-Sanchez
J.L. Garcia-Sanchez
AMA. Mancini
A. Mancini
Scott James DoyleScott James Doyle
Scott James Doyle
MGM. Garcia-Munoz
M. Garcia-Munoz
JMJ. Maza-Ortega
J. Maza-Ortega

27 May 2010 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JOJose Maria Maza Ortega
Jose Maria Maza Ortega
JRJosé Antonio Rosendo-Macias
José Antonio Rosendo-Macias
AGAntonio Gomez-Exposito
Antonio Gomez-Exposito
SCSergio Ceballos-Mannozzi
Sergio Ceballos-Mannozzi
MBManuel Barragán-Villarejo
Manuel Barragán-Villarejo
This paper analyzes the feasibility and convenience of applying the efficient discrete Fourier transform (DFT) techniques for the computation of reference currents in active power filters. Existing methods designed for this purpose rely on a high-pass filter in order to obtain the harmonic components of the load current to be filtered. Among these methods, the stationary reference frame (SRF) method reveals itself as the most accurate one because of its inherent immunity to distorted voltage conditions. In this paper, two different implementations of the running DFT, including their recursive and nonrecursive versions, are compared to the SRF approach in terms of steady-state performance, adequacy of transient response, and computational effort. In addition to simulation results, an experimental setup is designed to prove the advantages of resorting to the DFT. Conceptual similarities between both schemes are also stressed in this paper.

10 March 2017 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
JOJose Maria Maza Ortega
Jose Maria Maza Ortega
MBManuel Barragán-Villarejo
Manuel Barragán-Villarejo
FGFrancisco de Paula García-López
Francisco de Paula García-López
JJJuan Jimenez
Juan Jimenez
JMJuan Manuel Mauricio
Juan Manuel Mauricio
AGAntonio Gomez-Exposito
Antonio Gomez-Exposito
Today's electricity paradigm requires that the notion of active distribution systems be introduced at both undergraduate and graduate curricula. This involves not only the customary theoretical foundations but also a suitable power engineering laboratory, where flexible enough and affordable resources allow students and researchers to carry out hands-on experiments reinforcing the concepts explained in the classroom. This paper describes the smart grid laboratory of the Power Engineering Group at the University of Seville, composed of a scaled-down distribution system, along with the required control and monitoring equipment, designed to help its users easily grasp the major influence that distributed generation and storage devices exert in the operation of medium-voltage distribution systems.

1 January 2020 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
FGFrancisco de Paula García-López
Francisco de Paula García-López
MBManuel Barragán-Villarejo
Manuel Barragán-Villarejo
JMJosé María Maza-Ortega
José María Maza-Ortega

3 August 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
KMKyriaki-Nefeli D. Malamaki
Kyriaki-Nefeli D. Malamaki
FCFrancisco Casado-Machado
Francisco Casado-Machado
MBManuel Barragán-Villarejo
Manuel Barragán-Villarejo
AGAndrei Mihai Gross
Andrei Mihai Gross
GKGeorgios Kryonidis
Georgios Kryonidis
Charis S. DemouliasCharis S. Demoulias
Charis S. Demoulias
The growing penetration of Converter-Interfaced Distributed Renewable Energy Sources (CI-DRES) has posed several challenges into the electric power systems, e.g., the instability caused by the intermittent nature of the primary sources, power quality issues, etc. Several algorithms have been proposed to mitigate the CI-DRES power fluctuations and reduce high active power ramp-rates (RRs) at the Point of Common Coupling (PCC) with the grid using energy storage systems (ESS). However, these algorithms present some drawbacks. In this paper, a new Ramp-Rate Limitation (RRL) control method is proposed to address existing gaps in the technical literature. This algorithm is performed considering the connection of a Supercapacitor (SC) at the DC-link of a DRES converter. The relationship between the SC voltage and the degree to which the RRL is achieved is established, aiming to reduce the SC voltage fluctuations and increase the SC life time. The RRL control is validated in a real experimental testbed and compared to state-of-the-art approaches. This control is also modelled in Matlab/Simulink in order to perform techno-economic investigations on the influence that several parameters (SC size, SC charging/discharging cycles, cost, etc.) have on the achieved RRL at the DRES PCC.