Martina Oria

Mrs. Martina Oria

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
MOMartina Oria
Martina Oria
RFRICCARDO FERRERO
RICCARDO FERRERO
CAChiara Andreis
Chiara Andreis
MVMARTA VICENTINI
MARTA VICENTINI
RERuben Van Engen
Ruben Van Engen
Alessandra ManzinAlessandra Manzin
Alessandra Manzin
The aim of this work is the generation of realistic synthetic mammograms, using as an input of the imaging acquisition simulation process digital anthropomorphic phantoms, reconstructed from sets of dedicated breast computed tomography (BCT) images from different patients. The voxel-based structure and the segmentation into fibroglandular, adipose and skin tissues are performed through trivariate tensor-product B-spline approximation and morphological operations. The obtained phantoms can be modified by means of geometrical transformations that replicate typical breast shape deformities, and by locally introducing virtual masses and calcifications. After simulating biomechanical compression of the 3D breast phantoms, we generate the mammograms in both craniocaudal (CC) and mediolateral oblique (MLO) views, modelling the x-ray interaction with breast tissues with a Monte Carlo approach implemented in the in silico breast imaging pipeline VICTRE. The methodology proposed here can contribute to the creation of synthetic mammogram databases, to be used for in silico testing of diagnostic and therapeutic techniques, as well as for the validation of artificial intelligence (AI) systems in diagnostic imaging and cancer screening. The great advantage is that, from a single BCT scan, it is possible to generate multiple realistic mammograms, with different anatomical features, in terms of breast shape and size, and type and location of lesions.

10 October 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
MVMARTA VICENTINI
MARTA VICENTINI
MOMartina Oria
Martina Oria
EREva Raina
Eva Raina
MDManuela Durando
Manuela Durando
Alessandra ManzinAlessandra Manzin
Alessandra Manzin
Background/Objectives: The automatic and accurate segmentation of mass lesions in mammograms is a critical step in the computer-aided diagnosis workflow. This study evaluates the mask region-based convolutional neural network (Mask R-CNN), a robust deep learning model for instance-level segmentation, highlighting its growing potential in medical imaging. Methods: Following configuration optimization, the model is applied to mammography images from the CSAW-CC and TOMPEI-CMMDs, which provide masks annotated by breast radiology experts, to be used as a ground truth. To quantify shape and contour discrepancies with respect to the radiologists’ annotations, performance is evaluated with both overlap- and distance-based metrics. Furthermore, the model is tested on synthetic mammograms and benchmarked against classical segmentation methods (Otsu thresholding, gradient vector flow active contour, and Chan–Vese segmentation), Fuzzy c-means clustering, and the state-of-the-art Medical Segment Anything (MedSAM) model. Results: By leveraging transfer learning, a limited dataset suffices for stable training, with the network converging by the 10th epoch. The optimal configuration achieves a bounding box average precision (BBox AP) of 0.80 and a segmentation average precision (Segm AP) of 0.58. Evaluated on a test set of real mammograms, the model correctly identifies the lesions, yielding an average Dice similarity coefficient (DSC) of 0.87 and an average intersection over union (IoU) of 0.77, performance aligned with the current state of the art. Conclusions: Mask R-CNN has emerged as a reliable and robust model for breast lesion segmentation; compared to the other methods evaluated in this study, it demonstrates superior performance across both overlap- and distance-based metrics. The model exhibits high DSC and IoU scores even on synthetic mammograms with a priori known lesion profiles, which can be used as an objective ground truth to mitigate annotation bias from inter-operator variability among radiologists.