This paper mainly concentrates on the thermal conductivity and photo-thermal conversion performance of polyethylene glycol (PEG)/graphene nanoplatelets (GNPs) composite phase change materials (PCMs). The temperature-assisted solution blending method is used to prepare PCM with different mass fraction of GNPs. According to the scanning electron microscope (SEM), GNPs are evenly distributed in the PEG matrix, forming a thermal conduction pathway. The Fourier transform infrared spectra (FT-IR) and X-ray diffraction (XRD) results show that the composites can still inherit the crystallization structure of PEG, moreover, there are only physical reactions between PEG and GNPs rather than chemical reactions. Differential scanning calorimeter (DSC) and thermal conductivity analysis results indicate that it may be beneficial to add a low loading ration of GNPs to obtain the suitable latent heat as well as enhance the thermal conductivity of composites. To investigate the change in the rheological behavior due to the effect of GNPs, the viscosity of the composites was measured as well. The photo-thermal energy conversion experiment indicates that the PEG/GNPs composites show better performance in photothermal energy conversion, moreover, the Ultraviolet-visible-Near Infrared spectroscopy is applied to illustrate the reasons for the higher absorption efficiency of PEG/GNPs for solar irradiation.
1 June 2023 in Journal of Materials in Civil Engineering
The road performance and temperature-regulating properties of asphalt binders modified with novel polyethylene glycol (PEG)/porous silica (PS) form-stabilized phase-change materials (PEG/PS-fs-PCMs) were studied. PS and PEG were used as the supporting substance and PCMs. The results showed that PEG/PS-fs-PCMs could maintain a maximum weight percentage of 70% without leakage, at temperatures as high as 90 °C. The PEG/PS-fs-PCMs exhibited stable chemical structures, excellent thermal stability, high heat storage density, and suitable phase-change temperature. Based on conventional physical tests, the addition of PEG/PS-fs-PCMs can increase the viscosity and the degree of hardness of asphalt binders; thus, achieving an excellent comprehensive performance of the modified asphalt binder depends on determining the optimal dosage of PEG/PS-fs-PCMs. Additionally, incorporating PEG/PS-fs-PCM particles into the asphalt binder can enhance its ability to withstand permanent deformation at elevated temperatures, while PEG/PS-fs-PCMs mainly act as a filler, weakening the cohesive force of the asphalt molecules, and preventing the ductility of asphalt from expansion, according to DSR and BBR tests. Moreover, the use of PEG/PS-fs-PCMs can enhance the heat transfer properties of the asphalt binders, resulting in an improved temperature regulation performance. However, the accumulation of PEG/PS-fs-PCM particles on asphalt binders can negatively impact the storage stability of the modified asphalt binders, because of the difference in density between the two materials.
The purpose of this study was to investigate the properties of a die hardener penetrated layer and evaluate its protective effects on the surface of die stone. A commercial die hardener (PDQ die hardener, Whipmix corp., USA) was tested on a die stone (GC Fujirock® EP die stone, GC Europe, Belgium) and a dental plaster (Dental Stone, United States Gypsum Company, USA). Nanoindentation and micro-scratch tests were performed on both coated and uncoated specimens. The scratch damage was observed by SEM and the penetration depth of die hardener was detected by the affiliated EDX. Upon drying, the die hardener penetrated into the die stone to a depth of 3-5 μm, and deposited a thin film on the surface of die stone. Although the die hardener penetrated layer did not show improved mechanical properties, the die hardener film on the surface did protect the specimens from abrasion damage.
To address the deficiencies of traditional emulsified asphalt-pavement maintenance material in cohesive strength, high-temperature rutting resistance, as well as adhesion to aggregates, this study developed waterborne epoxy resin-modified emulsified asphalt (WEA) binders using a two-component waterborne epoxy resin (WER) and systematically investigated their modification mechanisms and pavement performance. The results indicated that WER emulsions and curing agents could polymerize to form epoxy resin within the emulsified asphalt dispersion medium, with the modification process dominated by physical interactions. When the WER content exceeded 12%, a continuous modifier network structure was established within the emulsified asphalt. The epoxy resin formed after curing could significantly increase the polarity component of the binder, thereby increasing the surface free energy. The linear viscoelastic range of the WEA binder exhibited a negative correlation with the dosage of the WER modifier. Notably, when the WER content exceeded 6%, the high-temperature stability (rutting resistance and elastic recovery performance) of the binder was significantly enhanced. Concurrently, stress sensitivity and frequency dependence gradually decrease, demonstrating superior thermomechanical stability. Furthermore, WER significantly enhanced the interfacial interaction and adhesion between the binder and aggregates. However, the incorporation of WER adversely affects the low-temperature cracking resistance of the binder, necessitating strict control over its dosage in practical applications.
The study was to evaluate the performance of different materials used in dental operative simulation and compare them with those of natural teeth. Three typical phantom teeth materials were compared with extracted permanent teeth by a nanoindentation system and evaluated by students and registered dentists on the drilling sensation of the materials. Moreover, the tool life (machinability) of new cylindrical diamond burs on cutting the sample materials was tested and the burs were observed. Although student and dentist evaluations were scattered and inconclusive, it was found that elastic modulus (E) and hardness (H) were not the main factors in determining the drilling sensation of the materials. The sensation of drilling is a reflection of cutting force and power consumption.An ideal material for dental simulation should be able to generate similar drilling resistance to that of natural tooth, which is the machinability of the material.