Cui jianming Jianming

Dr. Cui jianming Jianming


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
1Y1 Yu
1 Yu
Zhao MingzhiZhao Mingzhi
Zhao Mingzhi
Chun ChangChun Chang
Chun Chang
YLYiran Liu
Yiran Liu
CJCui jianming Jianming
Cui jianming Jianming
EJErkin Turobovich Juraev
Erkin Turobovich Juraev
Solar hot-air drying technology has developed rapidly in the field of low-temperature fruit and vegetable processing; however, fluctuations in solar irradiance affect the stability of system energy supply and energy utilization efficiency. In this study, a cascaded photovoltaic/thermal (PV/T) solar drying system was constructed, and drying experiments were conducted on slices of the “Hohhot Hongying No. 2” carrot cultivar at 40, 45, 50, 55, and 60 °C. A hierarchical normalization method was employed to reduce the effects of meteorological differences among the experimental days, and the thermal performance, energy consumption, and drying kinetic characteristics of the material were analyzed. The results showed that the quasi-steady-state thermal efficiency of the system ranged from 29.7% to 38.3%. At 50 °C, the electrical energy consumption per unit mass of water removed was the lowest, at 0.430 kWh/kg. The effective moisture diffusivity calculated based on Fick’s second law increased from 8.99 × 10−9 to 1.98 × 10−8 m2/s with increasing drying temperature, and the coefficients of determination under all operating conditions were greater than 0.9906. Arrhenius fitting yielded a pre-exponential factor of 4.37 × 10−3 m2/s and an activation energy of 34.09 kJ/mol. Under the present experimental conditions, 50 °C exhibited a relatively favorable balance between energy consumption and drying rate within the investigated temperature range. These findings may provide a reference for selecting the operating parameters of small-scale PV/T solar drying systems. Nevertheless, further repeated experiments and product-quality assessments are required to verify the broader applicability of the results.

22 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YLYiran Liu
Yiran Liu
Zhao MingzhiZhao Mingzhi
Zhao Mingzhi
CJCui jianming Jianming
Cui jianming Jianming
BYBoran Ye
Boran Ye
CYChen Yang
Chen Yang
Fresnel high-concentration photovoltaic/thermal (HCPV/T) systems operating in sandy environments are susceptible to natural lens soiling, which attenuates the effective concentrated solar input and alters electrical and thermal performance. Natural-soiling comparison tests were conducted over 0–28 d, and an SD-CNN-BiLSTM-Attention model was developed to forecast cell-center temperature and electrical power 5, 10, and 20 min ahead. At a surface soiling density of 10.760 g·m−2, current and electrical power decreased by 38.37% and 39.28%, respectively, relative to the concurrently operated clean-reference unit; cell-center temperature and water-tank temperature rise decreased by 7.74% and 15.13%. Thermal power also showed an overall downward trend, although the magnitude was affected by relatively large measurement uncertainty. Under grouped cross-validation, temperature RMSEs were 0.473, 0.515, and 0.555 °C at 5, 10, and 20 min, corresponding to reductions of 8.34%, 21.68%, and 44.07% relative to Persistence. Electrical-power RMSEs were 0.661, 0.618, and 0.640 W, with an 18.24% reduction relative to Persistence at 20 min. Ablation analysis showed a limited contribution from surface soiling density at 5 and 10 min but a clearer contribution at 20 min. These results support electrical and thermal performance assessment and short-term operational forecasting of Fresnel HCPV/T systems in sandy environments.