1 Yu

Dr. 1 Yu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
Zhao MingzhiZhao Mingzhi
Zhao Mingzhi
1Y1 Yu
1 Yu
Chun ChangChun Chang
Chun Chang
DBDaorina Bao
Daorina Bao
AMAohan Mei
Aohan Mei
NWNingbo Wang
Ningbo Wang
Photovoltaic power generation is rapidly developing as a kind of renewable energy that can protect the ecological environment. The establishment of photovoltaic power stations in desertification areas can play a very important role in desert windbreaks and sand fixation as well as improve the ecological environment. The realization of the effective integration of photovoltaics and deserts can have multiple benefits for the economy, society, and ecology. However, the deposition of sand and dust caused by environmental factors in desertification areas can seriously affect the power generation efficiency of PV modules. In this study, the output characteristics of photovoltaic modules were tested under three wind speed conditions (5 m/s, 10 m/s, and 15 m/s), with different sand densities, sand particle sizes, and inclination angles. The experimental study showed that the module’s output power gradually decreased with an increase in the density of accumulated sand; the sand accumulation density on the surface of the photovoltaic module increased from 0 to 40 g/m2, and the maximum output power decreased by 32.2%. As the sand particle size increased, the maximum output power of the module rose and was gradually stabilized in the three wind speed groups. As the sand particle size increased, the maximum output power of the module increased and gradually stabilized in the three wind speed groups. When the wind speed was 15 m/s, the component output power of the angle had the largest drop; the tilt angle was 60° when the relative output power rate reached the minimum (i.e., 86.5%); that is, there was electrical energy loss of approximately 13.7%. The sand particle size and accumulated sand density were the control variables related to the module temperature and the transmittance of the proportion of the impact of the module filling factor differences. According to the curve analysis of the filling factor in different sand accumulation densities, the filling factor first increased and then decreased. In this test, the filling factor at the sand accumulation density of 35 g/m2 (module temperature valley) reached the peak value. The change trend for the component filling factor under different sand particle sizes fluctuated.

22 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
1Y1 Yu
1 Yu
Zhao MingzhiZhao Mingzhi
Zhao Mingzhi
Chun ChangChun Chang
Chun Chang
YLYiran Liu
Yiran Liu
CJCui jianming Jianming
Cui jianming Jianming
EJErkin Turobovich Juraev
Erkin Turobovich Juraev
Solar hot-air drying technology has developed rapidly in the field of low-temperature fruit and vegetable processing; however, fluctuations in solar irradiance affect the stability of system energy supply and energy utilization efficiency. In this study, a cascaded photovoltaic/thermal (PV/T) solar drying system was constructed, and drying experiments were conducted on slices of the “Hohhot Hongying No. 2” carrot cultivar at 40, 45, 50, 55, and 60 °C. A hierarchical normalization method was employed to reduce the effects of meteorological differences among the experimental days, and the thermal performance, energy consumption, and drying kinetic characteristics of the material were analyzed. The results showed that the quasi-steady-state thermal efficiency of the system ranged from 29.7% to 38.3%. At 50 °C, the electrical energy consumption per unit mass of water removed was the lowest, at 0.430 kWh/kg. The effective moisture diffusivity calculated based on Fick’s second law increased from 8.99 × 10−9 to 1.98 × 10−8 m2/s with increasing drying temperature, and the coefficients of determination under all operating conditions were greater than 0.9906. Arrhenius fitting yielded a pre-exponential factor of 4.37 × 10−3 m2/s and an activation energy of 34.09 kJ/mol. Under the present experimental conditions, 50 °C exhibited a relatively favorable balance between energy consumption and drying rate within the investigated temperature range. These findings may provide a reference for selecting the operating parameters of small-scale PV/T solar drying systems. Nevertheless, further repeated experiments and product-quality assessments are required to verify the broader applicability of the results.

17 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
Zhao MingzhiZhao Mingzhi
Zhao Mingzhi
FBFeng Bai
Feng Bai
1Y1 Yu
1 Yu
YLYuru Liu
Yuru Liu
YMYixuan Ma
Yixuan Ma
BRBakhramzhan Rasakhodzhaev Rasakhodzhaev
Bakhramzhan Rasakhodzhaev Rasakhodzhaev
As desertification intensifies, greenhouses in arid regions are increasingly challenged by severe water scarcity and low water utilization efficiency. Traditional greenhouse HVAC systems are often inadequate in efficiently recovering condensate water. This study addressed these challenges by investigating, through wind tunnel experiments, the fin angle and inlet wind speed for optimal condensation and heat transfer performance of a straight-fin heat exchanger in desert greenhouse environments. The experimental findings revealed that under low-temperature conditions, vertical fins facilitated gravity-driven droplet removal, resulting in a maximum condensate amount of 524.2 g within 120 min. Conversely, under high-temperature conditions, a fin angle of 45° optimally balanced turbulent disturbances and liquid film stability, producing a condensate amount of up to 887.1 g in the same timeframe. Additionally, wind speed tests at a 45° fin angle identified a critical wind speed of 1.5 m/s, beyond which the condensate amount significantly decreased. Furthermore, when the fin inclination reached or exceeded 60°, flow separation occurred, reducing the effective heat transfer area and negatively impacting the exchanger efficiency. Overall, the study provides significant insights into water conservation and sustainable environmental utilization by enhancing condensate recovery efficiency.