Maria Vinogradova

Mrs. Maria Vinogradova

orcid

Research Focus & Metrics

Representative Publications

View All Publications
16 June 2024 in Materials Letters
Verified
Journal Article
Open access
MVMaria Vinogradova
Maria Vinogradova
EKElizaveta Klyatskina
Elizaveta Klyatskina
VAVicente Amigó
Vicente Amigó
FSFrancisco Segovia
Francisco Segovia

13 October 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MVMaria Vinogradova
Maria Vinogradova
EKElizaveta Klyatskina
Elizaveta Klyatskina
ABAngela Bermudez-Castañeda
Angela Bermudez-Castañeda
FSFrancisco Segovia-López
Francisco Segovia-López
Vicente Amigo BorrasVicente Amigo Borras
Vicente Amigo Borras
Ti-35Nb-xSn (x = 0, 4, 6 wt.%) alloys were consolidated by Electrical Resistance Sintering (ERS) at 11 and 12 kA to address the elastic-modulus mismatch and ion-release limitations of Ti-6Al-4V, exploiting the β-stabilizing effect of Nb and oxide-reinforcing effect of Sn. As the corrosion and tribocorrosion behavior of ERS-processed Ti-Nb-Sn alloys has not previously been reported, this study evaluated the combined effect of Sn content and sintering current on static corrosion resistance, tribocorrosion, wear, and ion release in Hartmann–Ringer solution and sulfuric acid. Rietveld refinement revealed a disproportionate increase in α-Ti fraction for the 6 wt.% Sn alloy sintered at 12 kA (41.2 wt.% vs. 29.3 wt.% at 11 kA), coinciding with a shift from smeared, ductile wear debris at 11 kA to coarser, fractured debris at 12 kA, and with an inversion of the sintering-current effect on static corrosion resistance between Sn-free and Sn-containing alloys. The alloy with 6 wt.% Sn sintered at 11 kA showed the best overall performance, combining the highest corrosion resistance, the lowest wear volume loss in sulfuric acid, and stable post-tribocorrosion microhardness, while showing comparable wear resistance to the 4 and 6 wt.% Sn alloys sintered at 12 kA in Hartmann–Ringer solution. Ion release rates remained in the range reported for comparable Ti-Nb-Sn biomedical alloys, supporting the biocompatibility potential of the studied compositions.

21 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MVMaria Vinogradova
Maria Vinogradova
EKElizaveta Klyatskina
Elizaveta Klyatskina
ABAngela Bermudez-Castañeda
Angela Bermudez-Castañeda
FSFrancisco Segovia-López
Francisco Segovia-López
Vicente Amigo BorrasVicente Amigo Borras
Vicente Amigo Borras
Ti35NbxSn alloys produced via Electrical Resistance Sintering were evaluated for their potential in biomedical applications, particularly dental implants. The study focused on the effects of Sn content and sintering current on electrochemical properties and tribocorrosion behaviour. Testing in Hartmann-Ringer solution and sulfuric acid showed that alloys with 6 wt.% Sn sintered at 11 kA offered the best performance, demonstrating superior corrosion resistance, minimal wear rates, and stable microhardness. Sn significantly enhanced the stability of passive oxide films, aiding in repassivation during slide. Ion release remained below acceptable levels, indicating biocompatibility.