Sreekanthreddy Chalapala

Dr. Sreekanthreddy Chalapala

University of Michigan–Dearborn, Dearborn, Michigan, USA
+1
orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2026 in Energies
Verified
Journal Article
Open access
PDF file
RMRavi Eswar Kodumur Meesala
Ravi Eswar Kodumur Meesala
RURamanjaneya Reddy Udumula
Ramanjaneya Reddy Udumula
MMMohammed Momin
Mohammed Momin
KCKasi Ramakrishnareddy Ch
Kasi Ramakrishnareddy Ch
RMRambabu Motamarri
Rambabu Motamarri
SCSreekanthreddy Chalapala
Sreekanthreddy Chalapala
DC microgrids are in high demand due to the integration of renewable energy supplies (RES), including fuel-cells and solar photovoltaics. In this application, a high voltage gain (VG) DC/DC converter is an indispensable module that supports the connection of low voltage (LV) RES to the high voltage (HV) DC grid. This article presents an ultra-VG step-up DC/DC converter (SDC) featuring low complexity and a common grounding design. The proposed SDC utilizes a total of 10 elements in the circuit and operates with dual duty ratios. With this design and operation, ultra-VG is attained with low duty ratios for individual switches, which do not exceed 0.5. Therefore, switching at extreme duty ratio is obviated. The analysis of SDC is presented, which includes steady state operation, VG derivation in ideal and non-ideal modes, parameter design, and practical power loss. With a 200 W load power, the proposed SDC prototype is experimentally evaluated, and test results are displayed where the practical VG attained is 9.525 with dual duty ratio of switches valued at 0.4, gaining 95.2% efficiency. The extensive comparisons reveal the proposed SDC’s significant contributions over existing SDCs, including improved VG for low duty ratios for individual switches along with a common grounded low complexity design. Hence, the proposed SDC is attractive for ultra-VG application.

10 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
RMRavi Eswar Kodumur Meesala
Ravi Eswar Kodumur Meesala
RURamanjaneya Reddy Udumula
Ramanjaneya Reddy Udumula
KCKasi Ramakrishnareddy Ch
Kasi Ramakrishnareddy Ch
RMRambabu Motamarri
Rambabu Motamarri
SCSreekanthreddy Chalapala
Sreekanthreddy Chalapala
Intuitive response and multi-objective control are well-known features of Finite Control Set Predictive Torque Control (FCSPTC). However, its implementation difficulty is a result of limitations such as high computations, strong model parameter dependency in control, and time-consuming tuning efforts for weighting factors in a cost function. Particularly, when FCSPTC is applied to a Multi-Level Inverter (MLI)-supplied motor drive, computation complexity is predominant. The proposed research work in this paper offers a new FCSPTC to dual two-level VSIs supplied for an Open Winding Permanent Magnet Synchronous Motor (OWPMSM) drive. The contributions of the proposed FCSPTC for the OWPMSM drive are the following. (i) Simplicity: There are fewer operational steps in control and limited evaluations with five prediction voltage vectors (VVs) out of 19, and a flux weighting-factor-less design is used by adopting a voltage cost function. (ii) Robustness: There is less parameter dependency in control through the involvement of stator resistance only. (iii) Switching frequency reduction: The application of an optimal switching state from the redundant switching states of optimal VVs is used to generate fewer switching state transitions, where the process is independent from the switching frequency weighting factor. According to theoretical and experimental findings, it is evident that the proposed FCSPTC technique operates effectively without the weighting factor and provides the above-stated features, resulting in an optimal response in flux, torque and current, switching frequency reduction, and low-complexity operation. The proficiency of the proposed FCSPTC technique is experimentally verified by comparing it with existing control schemes.