Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging. Recent studies have shown that cone beam computed tomography has advantages when imaging metal artifacts. Patients with hearing loss or vertigo, who have undergone stapedotomy, often present a challenge for otologic surgeons. Imaging studies can deliver crucial additional information. Methods: A retrospective analysis of imaging studies and clinical data in a tertiary care center were carried out. Forty-one patients with forty-five implanted ears were evaluated in the study. All included patients had been implanted with a platinum–fluoroplastic (n = 19) or titanium (n = 26) piston and subsequently had undergone imaging months or years after surgery for various reasons. Patients underwent computed tomography or cone beam computed tomography of the temporal bone depending on availability. Piston visualization, prosthesis length, vestibular intrusion and audiologic results were compared between the groups. Piston position on imaging studies were compared to intraoperative findings. Results: Functional length measurements of all prostheses were carried out with a mean error of −0.17 mm (±0.20). Platinum–fluoroplastic protheses were significantly underestimated in length compared to titanium prostheses. To analyze the material-dependent difference in the measurement errors of the imaging techniques the interaction was tested in an ANOVA model and showed no statistically significant result (p = 0.24). The blinded neuroradiologist viewed two implants, both platinum–fluoroplastic pistons, as located outside of the vestibule due to an underestimation of the prothesis length and the missing radiodensity of the lower end of the prosthesis. Conclusion: Surgeons and radiologists should be aware of the different types and radiologic features of stapes prostheses and the missing radiodensity of some protheses parts. Cone beam computed tomography is an imaging alternative with a potential advantage of reduced radiation in patients after stapes surgery suffering from vertigo or hearing loss to evaluate piston position.
Background: The use of photon-counting detector computed tomography (PCD-CT) has improved image quality in cardiac, pulmonary, and musculoskeletal imaging. Abdominal imaging research, especially about the use of PCD-CT in hepatocellular carcinoma (HCC), is sparse. Objectives: We aimed to compare the image quality of tumors, the liver parenchyma, and the vasculature in patients with HCC using PCD-CT reconstructions at different slice thicknesses and kernels to identify the most appropriate settings for the clinical routine. Methods: CT exams from twenty adult patients with HCC performed with a clinically approved, first-generation PCD-CT scanner (Naeotom Alpha®, Siemens Healthineers), were retrospectively reviewed. For each patient, images were reconstructed at four different sharp kernels, designed for abdominal imaging (Br40; Br44; Br48; Br56) and at three slice thicknesses (0.4 mm; 1 mm; 3 mm). The reconstruction with the Br40 kernel at 3 mm (Br403 mm) was used as a clinical reference. Three readers independently assessed the image quality of different anatomical abdominal structures and hypervascular HCC lesions using a five-point Likert scale. In addition, image sharpness was assessed using line-density profiles. Results: Compared with the clinical reference, the Br441 mm and Br481 mm reconstructions were rated superior for the assessment of the hepatic vasculature (median difference +0.67 [+0.33 to +1.33], p < 0.001 and +1.00 [+0.67 to +1.67], p < 0.001). Reconstructions for Br401 mm (+0.33 [−0.67 to +1.00], p < 0.001), and Br443 mm (+0.0 [0.0 to +1.00], p = 0.030) were scored superior for overall image quality. The noise demonstrated a continuous increase when using sharper kernels and thinner slices than Br403 mm (p < 0.001), leading to a decrease in contrast-to-noise ratio. Although there was a trend toward increased image sharpness using the slope analysis with higher kernels, this was not significantly different compared with the reference standard. Conclusion: PCD-CT reconstruction Br401 mm was the most suitable setting for overall image quality, while reconstructions with sharper kernels (Br441 mm and Br481 mm) can be considered for the assessment of the hepatic vasculature in patients with HCC.
Background/Objectives: The ultra-high-resolution (UHR) mode of photon-counting detector computed tomography (PCD-CT) is the most dose-intensive series of a multiphase pancreatic protocol in relation to its scan length, and the pancreas cannot be localised on a topogram. We assessed whether an ultra-low-dose (ULD) unenhanced planning series reduces its scan range and dose without compromising complete depiction of the pancreas. Methods: In this prospective single-centre study, 61 pancreatic protocol examinations in 56 patients were performed on a first-generation dual-source PCD-CT. Following a protocol change, the UHR scan range was planned from the topogram in group A (n = 30) and from a ULD unenhanced series in group B (n = 31). Dose indices, scan length, margins to the pancreas and completeness of depiction were recorded. Results: The UHR scan range was 27% shorter in group B (114 vs. 160 mm; p < 0.001), driven by the cranial margin (−58%; p < 0.001) rather than the caudal margin (p = 0.076). Neither the volume CT dose index nor the size-specific dose estimate of the UHR series differed (p = 0.74 and p = 0.35), yet its dose–length product fell by 25% (p = 0.003) and its share of the dose excluding the mandatory venous phase fell from 62.0% to 50.7% (p < 0.001). The total dose was 7.5% lower without reaching significance (p = 0.37). Incomplete depiction occurred in 5 of 30 vs. 5 of 31 examinations (p = 1.00). The body habitus was closely matched. Conclusions: A ULD planning series was associated with a more tightly targeted UHR pancreatic phase, with a 27% shorter scan range and a 25% lower dose–length product for that series, and with no detected increase in incomplete depiction of the pancreas. With topogram-based planning alone, over-scanning was most pronounced at the cranial border. The reduction was confined to the ultra-high-resolution series and was statistically significant there; the total examination dose was lower with ultra-low-dose planning, but this difference was not statistically significant and no conclusion about total dose should be drawn from it.