Juha Kostamovaara

Juha Kostamovaara


Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Open access
Sahba JahromiSahba Jahromi
Sahba Jahromi
JJJussi-Pekka Jansson
Jussi-Pekka Jansson
PKPekka Keränen
Pekka Keränen
JKJuha Kostamovaara
Juha Kostamovaara
A single-chip receiver for pulsed laser direct time-of-flight 3-D imaging applications has been realized in a 0.35-μm HV CMOS technology. The chip includes a 32 x 128 single-photon avalanche diode (SPAD) array [35% fill factor (FF)] and 257 time-to-digital converters (TDCs) with a ~78-ps resolution. Two adjacent rows (2 x 128 SPADs) at a time can be selected for simultaneous measurement, i.e., 16 measurement cycles are needed to cover the whole array. SPADs are capable of operating in a gated mode in order to suppress dark and background light-induced detections. The IC was designed to be used in a solid-state 3-D imaging system with laser illumination concentrated in both time (short sub-ns pulses) and space (targeting only the active rows of the SPAD array). The performance of the receiver IC was characterized in a solid-state 3-D range imager with flood-pulsed illumination from a laser diode (LD)-based transmitter, which produced short [~150-ps full-width at half-maximum (FWHM)] high-energy (~3.8-nJ pulse/~14-W peak power) pulses at a pulsing rate of 250 kHz when operating at a wavelength of 810 nm. Two detector/TDC ICs formed an 8k pixel receiver, targeting a field-of-view of ~42° x 21° by means of simple optics. Frame rates of up to 20 fps were demonstrated with a centimeter-level precision in the case of Lambertian targets within a range of 3.5 m.

9 April 2020 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Open access
ABAram Baharmast
Aram Baharmast
SKSami Kurtti
Sami Kurtti
JKJuha Kostamovaara
Juha Kostamovaara
This paper presents a Time-of-Flight laser radar receiver based on pulse-shaping at the input to the receiver channel, in which the first zero-crossing point of the converted pulse is marked as the timing moment. In this technique, an LC resonator is combined with a nonlinear feedback TIA to achieve high accuracy and high precision within a wide dynamic range. The key advantage is that the receiver does not require any post compensation or gain control techniques so that the total complexity of the TOF radar is reduced considerably. Measurements made in a 0.35μ m standard CMOS process show a bandwidth of 230MHz and an input-referred noise of 70nA RMS. The receiver chip consumes 155mW power from a 3.3V supply. The single-shot precision and accuracy of the receiver within a dynamic range of 1:50,000 are ~ 15mm(SNR=12) and ~ ± 15mm respectively. A wider dynamic range can be achieved with a larger accuracy tolerance. The functionality of the proposed receiver channel is also verified over an input pulse variation and temperature range of 0°C to 50°C.

29 October 2015 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
PKPekka Keränen
Pekka Keränen
JKJuha Kostamovaara
Juha Kostamovaara
A time-to-digital (TDC) converter based on cyclic interpolators has been designed. The TDC is designed to be used in a pulsed time-of-flight laser radar, where a long measurement range is required. The TDC's two interpolators provide a picosecond level resolution, which is combined with a main reference clock counter to give a measurement range of 327 μs. The interpolators measure time intervals with a switched-frequency ring oscillator. The frequency switching is used as a mechanism to amplify the quantization error in the cyclic interpolator. A digital calibration scheme is used for radix extraction. The interpolators' worst case INL is ±4.5 ps. Due to the interpolator's INL, the TDC's RMS precision is about 4.2 ps, while the worst and best case single-shot precisions are 5.5 ps and 1.7 ps, respectively. The overall accuracy of the TDC is better than 5 ps in a temperature range of -30 C to 70 C. The TDC is designed in 0.35 μm CMOS technology and consumes 80 mW at 0.8 MHz measurement rate.

19 August 2017 in Journal of Biomedical Optics
Verified
Journal Article
Open access
LSLaura Di Sieno
Laura Di Sieno
JNJan Nissinen
Jan Nissinen
LHLauri Hallman
Lauri Hallman
EMEdoardo Martinenghi
Edoardo Martinenghi
DCDavide Contini
Davide Contini
Alberto Dalla MoraAlberto Dalla Mora
Alberto Dalla Mora
We validate a miniaturized pulsed laser source for use in time-domain (TD) diffuse optics, following rigorous and shared protocols for performance assessment of this class of devices. This compact source (12×6 mm2) has been previously developed for range finding applications and is able to provide short, high energy (∼100 ps, ∼0.5 nJ) optical pulses at up to 1 MHz repetition rate. Here, we start with a basic level laser characterization with an analysis of suitability of this laser for the diffuse optics application. Then, we present a TD optical system using this source and its performances in both recovering optical properties of tissue-mimicking homogeneous phantoms and in detecting localized absorption perturbations. Finally, as a proof of concept of in vivo application, we demonstrate that the system is able to detect hemodynamic changes occurring in the arm of healthy volunteers during a venous occlusion. Squeezing the laser source in a small footprint removes a key technological bottleneck that has hampered so far the realization of a miniaturized TD diffuse optics system, able to compete with already assessed continuous-wave devices in terms of size and cost, but with wider performance potentialities, as demonstrated by research over the last two decades.

24 June 2016 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
SVSergey N. Vainshtein
Sergey N. Vainshtein
GDGuoyong Duan
Guoyong Duan
AFAlexey Filimonov
Alexey Filimonov
JKJuha Kostamovaara
Juha Kostamovaara
Although Marx-bank connection of avalanche transistors is widely used in applications requiring high-voltage nanosecond and subnanosecond pulses, the physical mechanisms responsible for the voltage-ramp-initiated switching of a single transistor in the Marx chain remain unclear. It is shown here by detailed comparison of experiments with physical modeling that picosecond switching determined by double avalanche injection in the collector-base diode gives way to formation and shrinkage of the collector field domain typical of avalanche transistors under the second breakdown. The latter regime, characterized by a lower residual voltage, becomes possible despite a short-connected emitter and base, thanks to the 2-D effects.

18 September 2018 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Open access
PKPekka Keränen
Pekka Keränen
JKJuha Kostamovaara
Juha Kostamovaara
This paper presents the design of a CMOS time-to-digital converter (TDC) used in a direct time-of-flight laser radar line receiver consisting of an array of single-photon avalanche diodes (SPADs) and 256 TDCs. The TDCs use the Nutt interpolation method, where the start/stop fine interpolators are based on a cyclic converter architecture. The cyclic converters use a delay-line-based time interval amplifier to double the quantization residue after each quantization cycle. The time amplifier, and the entire TDC array, does not need any biasing nor does the TDC results need any post-processing to provide sub-100-ps precision and uniformity across the TDC array, therefore making the design very robust and appealing for large designs where hundreds of TDCs are needed on a single chip. Fabricated in a 0.35 μm CMOS technology, a single TDC channel occupies an area of 0.03 mm² and consumes a power of 1.17 mW @ 100 kHz measurement rate. The TDC has a measurement range of 640 ns, and with a resolution of 15 bits, the LSB is 20 ps. Linearity is ensured by the Nutt interpolation method while the rms single-shot precision of the TDC channel is 72 ps. Thus, when LIDAR applications are considered, the TDC is capable of providing a range of 96 m with a precision of 1 cm without any post-processing or calibration.