The number of suitable techniques for spatially resolved measurements of wall temperatures in internal flows is limited. Thermography using thermochromic liquid crystals (TLCs) is an established method that relies on a surface colour change to measure temperatures within a narrow band. Temperature-sensitive paints (TSP), by contrast, provide continuous temperature distributions over a wider temperature range through temperature-dependent luminescence intensity. While TLCs exhibit a lower absolute measurement uncertainty within their calibrated temperature range, TSPs allow the surface temperature to be measured continuously throughout the test period. In this work, a single-layer TLC configuration (sTLC), a multilayer TLC configuration (mTLC), and TSP are applied in three ribbed subchannels, enabling a direct technique-specific comparison under equal conditions and simultaneous evaluation. The time-dependent surface temperatures are evaluated using a transient semi-infinite wall (SIW) approach adapted to each technique. For the investigated range, the geometric mean heat transfer coefficient (HTC) differs by approximately 4% between sTLC and mTLC and by approximately 13% between sTLC and TSP. Larger local deviations are confined to the immediate vicinity of the high-gradient flank, where TSP yields a lower peak HTC and a higher HTC on the adjacent lower-gradient side than the TLC reference. Lateral heat conduction within the substrate is discussed as a possible cause. The measured temporal surface-temperature evolution was also compared with the analytical model. Good agreement is obtained in regions with high HTC, whereas a temperature plateau is observed in the TSP measurements in regions with low HTC. Finally, Monte Carlo simulations are demonstrated to estimate the measurement uncertainty of all evaluated techniques.