With the increasing integration of low-temperature waste heat systems in aviation, large areas are needed for heat dissipation without causing significant pressure losses. Large-area skin heat exchangers (SHXs) are coming into focus as a possible solution. SHXs based on composite materials offer a promising approach due to their weight-saving potential. This article presents a structure-integrated SHX with a folded core using modern materials and design strategies. An analytical 1D heat transfer model, validated by measurements with temperature-sensitive paints (TSPs), was derived to efficiently identify the optimal parameter set in the design process of an SHX. The model focuses on transverse heat conduction effects in the facesheet for lateral heat distribution and uses these specifically for the overall mass-optimized configuration of the SHX. It is shown that with an optimally selected distance between the cooling channels in the case considered here, up to 12% more energy can be dissipated in relation to the total mass of the SHX. This article concludes with a sensitivity analysis of the analytical model. The influence of heat transfer, thermal conductivity in two spatial directions, and facesheet thickness on the optimal channel spacing is examined.
The number of suitable techniques for spatially resolved measurements of wall temperatures in internal flows is limited. Thermography using thermochromic liquid crystals (TLCs) is an established method that relies on a surface colour change to measure temperatures within a narrow band. Temperature-sensitive paints (TSP), by contrast, provide continuous temperature distributions over a wider temperature range through temperature-dependent luminescence intensity. While TLCs exhibit a lower absolute measurement uncertainty within their calibrated temperature range, TSPs allow the surface temperature to be measured continuously throughout the test period. In this work, a single-layer TLC configuration (sTLC), a multilayer TLC configuration (mTLC), and TSP are applied in three ribbed subchannels, enabling a direct technique-specific comparison under equal conditions and simultaneous evaluation. The time-dependent surface temperatures are evaluated using a transient semi-infinite wall (SIW) approach adapted to each technique. For the investigated range, the geometric mean heat transfer coefficient (HTC) differs by approximately 4% between sTLC and mTLC and by approximately 13% between sTLC and TSP. Larger local deviations are confined to the immediate vicinity of the high-gradient flank, where TSP yields a lower peak HTC and a higher HTC on the adjacent lower-gradient side than the TLC reference. Lateral heat conduction within the substrate is discussed as a possible cause. The measured temporal surface-temperature evolution was also compared with the analytical model. Good agreement is obtained in regions with high HTC, whereas a temperature plateau is observed in the TSP measurements in regions with low HTC. Finally, Monte Carlo simulations are demonstrated to estimate the measurement uncertainty of all evaluated techniques.